Original Industrial Spare Part
Hirschmann OZD PROFI 12M G12-1300 PRO Industrial Spare Part
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKUOZD PROFI 12M G12-1300 PRO
- CategoryPLC & Industrial Automation Modules
- BrandHirschmann
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: Hirschmann OZD PROFI 12M G12-1300 PRO Industrial Spare Part with SKU OZD PROFI 12M G12-1300 PRO.
Hirschmann OZD PROFI 12M G12-1300 PRO Industrial Spare Part: Spare Replacement & Downtime Risk Control
The Hirschmann OZD PROFI 12M G12-1300 PRO is a fiber optic link module (OLM) designed for PROFIBUS DP networks operating in demanding industrial environments. As a service-ready spare part, this unit enables maintenance engineers to execute rapid field replacements on aging PROFI Series communication infrastructure — minimizing unplanned downtime and preserving the integrity of time-critical automation loops.
In modern control cabinet environments, the OZD PROFI 12M G12-1300 PRO serves as the optical bridge between PROFIBUS DP master controllers and distributed I/O nodes, drives, or remote field devices. Its dual fiber port configuration (1300 nm multimode) supports ring and line topologies, making it a versatile backbone component in both legacy DCS architectures and contemporary PLC-based systems. When this module fails or degrades, the entire PROFIBUS segment it anchors can go silent — triggering cascading faults across connected drives, valve positioners, and remote I/O racks.
Stocking the OZD PROFI 12M G12-1300 PRO as a designated spare ensures your maintenance team can restore segment communication within a single shift rather than waiting weeks for emergency procurement. NINERMAS supplies this unit as a tested, original-specification spare with a 12-month warranty, pre-dispatch functional verification, and long-term availability commitment for lifecycle-extended automation systems.
Spare Maintenance Table
| Parameter | Specification |
|---|---|
| Part Number / SKU | OZD PROFI 12M G12-1300 PRO |
| Brand | Hirschmann |
| Series | OZD PROFI / PROFI Series |
| Product Type | Fiber Optic PROFIBUS Link Module (OLM) |
| Protocol | PROFIBUS DP |
| Fiber Wavelength | 1300 nm (Multimode) |
| Fiber Ports | 2 × ST connector (duplex) |
| RS-485 Port | 1 × Sub-D 9-pin (PROFIBUS DP) |
| Supply Voltage | 24 V DC (18–32 V DC operating range) |
| Power Consumption | Approx. 3 W typical |
| Baud Rate Support | 9.6 kbps – 12 Mbps (auto-detection) |
| Topology Support | Line, Tree, Redundant Ring |
| Operating Temperature | 0 °C to +60 °C |
| Storage Temperature | -25 °C to +85 °C |
| Protection Class | IP20 (DIN rail mount) |
| Mounting | 35 mm DIN rail |
| Dimensions (W×H×D) | Approx. 45 × 99 × 114 mm |
| Certifications | CE, UL (series-level) |
| Compatibility | Hirschmann OZD PROFI Series; PROFIBUS DP masters from Siemens, ABB, Schneider, Rockwell |
| Application Environment | Industrial automation, process control, manufacturing, utilities |
| Maintenance Recommendation | Inspect fiber connectors and RS-485 termination annually; replace if BER increases or segment errors are logged |
| Warranty | 12 Months (NINERMAS) |
| Origin | Germany |
Maintenance Planning for Continuous Operation
When scheduling a replacement of the OZD PROFI 12M G12-1300 PRO, experienced maintenance engineers treat the module swap as a trigger for a broader control cabinet inspection. The PROFIBUS segment served by this OLM typically interconnects multiple field devices through a shared electrical and optical infrastructure — and a single degraded component upstream or downstream can mask the root cause of recurring communication faults.
Begin by verifying the 24 V DC power supply feeding the OLM rail. Units such as the Hirschmann PS24 series or equivalent DIN-rail SMPS modules should be load-tested; a sagging supply voltage under full cabinet load is a common but overlooked cause of intermittent PROFIBUS segment dropouts. Simultaneously, inspect the PROFIBUS DP cable termination resistors at both segment ends — improper termination is the leading cause of reflection-induced communication errors that mimic OLM hardware failure.
Check the RS-485 repeater or bus coupler on the copper side of the segment. If the installation uses a hybrid copper-fiber topology, the copper segment’s Hirschmann OZD PROFI 12M RS-485 port and any inline PROFIBUS isolators or signal conditioners should be inspected for contact oxidation and connector wear. For segments running at 12 Mbps, even marginal impedance mismatches can cause sporadic slave dropouts that are difficult to diagnose without a PROFIBUS analyzer.
On the fiber side, clean and inspect the ST fiber connectors and patch cables connecting the OLM to the fiber backbone. Contaminated or cracked fiber ends are a frequent cause of elevated optical loss, particularly in environments with vibration or thermal cycling. If the installation uses multimode fiber patch cords older than five years, proactive replacement alongside the OLM module is recommended best practice.
For the broader control cabinet, this maintenance window should also cover the PROFIBUS DP master card (e.g., Siemens CP 5613, CP 342-5, or equivalent), any remote I/O racks (such as Siemens ET 200M or ET 200S stations) connected to the segment, and the 24 V DC distribution terminals and fuse holders supplying field devices. Inspect Phoenix Contact or Weidmüller terminal blocks for loose connections and verify that miniature circuit breakers (MCBs) protecting the PROFIBUS power rail are within rated capacity.
If the system includes an HMI panel (e.g., Siemens TP700 Comfort or similar) communicating via PROFIBUS, verify its DP address configuration has not drifted after a power cycle. Finally, review the PROFIBUS GSD file library on the PLC/DCS engineering station to confirm that the replacement OLM’s firmware version is compatible with the configured network parameters — particularly relevant when substituting across OZD PROFI sub-variants.
Site Replacement Workflow
Replacing the OZD PROFI 12M G12-1300 PRO on-site is a straightforward procedure when the correct spare is pre-staged and the segment topology is documented. Follow this workflow to minimize downtime and ensure a clean handover:
1. Pre-Replacement Verification: Confirm the replacement unit’s SKU matches the installed module exactly — OZD PROFI 12M G12-1300 PRO. Cross-check the fiber port type (ST, 1300 nm multimode) and supply voltage range against the cabinet wiring diagram. Do not substitute with the G12-1300 (non-PRO) variant without verifying baud rate and topology compatibility, as the PRO variant supports extended diagnostic and redundant ring features.
2. Segment Isolation: Place the PROFIBUS master in STOP mode or disable the affected DP segment from the engineering station. This prevents the master from generating bus fault alarms during the swap and protects connected slaves from receiving corrupted telegrams during the transition.
3. Physical Swap: Disconnect the fiber patch cables (label them before removal), unplug the RS-485 Sub-D connector, and remove the 24 V DC power connector. Release the DIN rail clip and slide out the faulty module. Install the replacement unit, reconnect power first, then RS-485, then fiber — in that sequence. Verify the power LED illuminates before reconnecting fiber.
4. Segment Restoration: Bring the PROFIBUS master back online and monitor the diagnostic buffer for any residual slave errors. A clean segment restart with no DP alarms within the first 60 seconds confirms a successful replacement. Log the swap in the maintenance record with the date, replaced unit serial number, and technician ID.
5. Post-Replacement Test: Run a 15-minute segment stability test under normal production load before releasing the line. This catches marginal fiber connection issues that only manifest under thermal expansion at operating temperature.
Spare Parts Support FAQ
Q1: Is the OZD PROFI 12M G12-1300 PRO still available as a new spare, or only as refurbished stock?
NINERMAS supplies the OZD PROFI 12M G12-1300 PRO as a service-ready spare part. Each unit undergoes pre-dispatch functional testing to verify optical output power, RS-485 signal integrity, and power supply operation. Long-term availability is maintained to support lifecycle-extended PROFI Series installations beyond the original manufacturer’s active production window.
Q2: How do I confirm compatibility before ordering if my installed unit has a different sub-variant label?
Provide your installed unit’s full nameplate SKU, firmware label (if visible), and fiber connector type (ST or SC) when contacting NINERMAS. Our technical team will cross-reference against the OZD PROFI compatibility matrix and confirm whether the G12-1300 PRO is a direct drop-in or requires a configuration adjustment on the PROFIBUS master side.
Q3: What does the 12-month warranty cover, and what is the claims process?
The 12-month warranty covers manufacturing defects and functional failures under normal operating conditions as specified in the product datasheet. It does not cover damage from incorrect wiring, overvoltage, or physical mishandling. To initiate a warranty claim, contact NINERMAS at sale@ninermas.com with the order reference, fault description, and photographic evidence. Replacement or repair is processed within the agreed lead time.
Q4: Can NINERMAS support long-term blanket orders for critical spare parts programs?
Yes. NINERMAS offers long-term supply agreements for procurement engineers managing critical spare parts inventories across multi-site automation installations. Blanket purchase orders, consignment stock arrangements, and annual inspection kits can be structured around your planned maintenance schedule. Contact our sales team to discuss volume commitments and lead-time guarantees for the OZD PROFI 12M G12-1300 PRO and related PROFI Series components.
| Product Series | Other series |
|---|---|
| Country of Origin | DE |
Catalog Continuation
Nearby part numbers around OZDPROFI.
Use this lane when the buyer is comparing adjacent model numbers, revision-near items, or closely related spare variants within the same brand family.
SKU: OZDPROFI12MG12
Hirschmann OZDPROFI12MG12 Spare Part for Industrial Maintenance
Catalog Continuation
More Hirschmann modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
SKU: OZD PROFI 12M G12 PRO
Hirschmann OZD PROFI 12M G12 PRO Service-Ready Spare Part
SKU: KTDE-V 943258-001
Hirschmann KTDE-V 943258-001 Safety-Reliable Coax Transceiver
Catalog Continuation
Alternative parts within PLC & Industrial Automation Modules.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
SKU: NA-1E221 1E-221.2
KONGSBERG NA-1E221 Service-Ready Spare Part for Maintenance
SKU: 023PLX0100 23 SGM-02U3B4L 10.004.22 RKH/W 500L 0040-99736
Yaskawa SGM-02U3B4L Retrofit AC Servo Motor for Legacy Systems
SKU: 6ES7341-1AH02-0AE0