The K9142TN represents Yokogawa's commitment to precision analytical instrumentation, delivering laboratory-grade pH measurement accuracy in industrial environments. This glass membrane electrode combines advanced electrochemical design with robust materials engineering to provide dependable pH monitoring across water treatment, chemical synthesis, pharmaceutical production, and food processing applications. Built for continuous operation in demanding conditions, the K9142TN addresses the critical need for reliable pH data that drives process optimization, regulatory compliance, and product quality assurance.
Process engineers and plant operators face constant challenges maintaining pH control in dynamic production environments. The K9142TN solves these challenges through its chemically resistant glass formulation, double junction reference system, and rapid response characteristics. Whether monitoring wastewater neutralization, controlling fermentation pH, or validating pharmaceutical buffer systems, this electrode delivers the measurement stability and longevity that industrial operations demand.
With proven performance in thousands of installations worldwide, the K9142TN stands as a trusted solution for organizations requiring accurate, repeatable pH measurement. Its compatibility with Yokogawa's analyzer ecosystem and standard BNC connectivity ensures seamless integration into existing control architectures while providing a clear upgrade path for aging pH measurement infrastructure.
→ Advanced Glass Membrane Technology
Proprietary glass formulation delivers fast 30-second response time while maintaining chemical resistance across pH 0-14 range. Reduces measurement lag in dynamic processes and improves control loop performance.
→ Double Junction Reference System
Ceramic double junction with Ag/AgCl reference prevents sample contamination and electrolyte depletion. Extends operational lifespan by 40-60% compared to single junction designs, reducing replacement costs and maintenance downtime.
→ Wide Temperature Operating Range
Functions reliably from 0-100°C (32-212°F) with integrated temperature compensation capability. Eliminates manual calibration adjustments and maintains accuracy across thermal cycling common in batch processes.
✓ Pressure-Rated Construction
Withstands process pressures up to 0.3 MPa without performance degradation. Suitable for inline installation in pressurized systems including reactor vessels and pipeline monitoring points.
✓ Universal Connectivity
Standard BNC connector ensures compatibility with Yokogawa analyzers and third-party transmitters. Simplifies replacement procedures and reduces spare parts inventory requirements.
✓ Chemical-Resistant Housing
Ruggedized polymer construction resists corrosive media, mechanical stress, and thermal shock. Maintains structural integrity in harsh industrial environments where conventional electrodes fail prematurely.
Water & Wastewater Treatment
Municipal treatment facilities deploy the K9142TN across multiple process stages—from raw water intake pH monitoring through final effluent discharge verification. The electrode's stability in variable water chemistry conditions ensures compliance with environmental discharge permits while optimizing chemical dosing for coagulation and neutralization processes. Typical installations include clarifier pH control, biological treatment monitoring, and post-treatment pH adjustment verification.
Chemical Manufacturing & Synthesis
Chemical plants utilize the K9142TN for real-time pH control during acid-base reactions, polymerization processes, and product formulation. Precise pH measurement prevents runaway reactions, ensures complete conversion, and maintains product specifications. The electrode's chemical resistance handles aggressive media including strong acids, caustic solutions, and organic solvents that would rapidly degrade standard pH sensors.
Pharmaceutical Production & Quality Control
Pharmaceutical manufacturers rely on the K9142TN for critical quality control points where pH directly affects active pharmaceutical ingredient (API) stability and bioavailability. Applications include buffer preparation verification, fermentation monitoring for biologics production, and final product pH testing. The electrode's fast response and accuracy support validation requirements for GMP-compliant manufacturing processes.
Food & Beverage Processing
Food processors depend on the K9142TN to maintain optimal pH conditions during fermentation, pasteurization, and preservation processes. Breweries monitor mash pH to optimize enzyme activity and extraction efficiency. Dairy operations control pH during cheese production and yogurt fermentation. The electrode's sanitary design and chemical resistance meet food-grade material requirements while delivering the accuracy needed for consistent product quality.
Power Generation & Cooling Systems
Power plants use the K9142TN to monitor boiler feedwater pH, preventing corrosion in high-pressure steam systems. Cooling tower pH control prevents scale formation and microbial growth while optimizing biocide effectiveness. The electrode's temperature tolerance and pressure rating suit these demanding applications where measurement failure can lead to costly equipment damage.
| Parameter | Specification |
|---|---|
| Model Number | K9142TN |
| Sensor Technology | Glass membrane pH electrode |
| Measurement Range | pH 0-14 (full scale) |
| Operating Temperature | 0-100°C (32-212°F) |
| Maximum Pressure | 0.3 MPa (3 bar / 43.5 psi) |
| Response Time | <30 seconds (90% response) |
| Junction Type | Ceramic double junction |
| Reference System | Ag/AgCl with KCl electrolyte |
| Electrical Connection | BNC or compatible connector |
| Housing Material | Chemical-resistant polymer |
| Glass Membrane | Low-impedance formulation |
| Weight | Approximately 100g |
Selection Criteria: Choose the K9142TN when your application requires general-purpose pH measurement in aqueous solutions with moderate chemical concentrations. For extreme pH environments (pH <1 or >13), high-temperature applications (>100°C), or specialized process conditions, consult Yokogawa's extended electrode portfolio. Consider combination-style electrodes for simplified installation where separate reference electrodes are impractical.
Integrated Temperature Sensing: When paired with compatible Yokogawa analyzers, the K9142TN supports automatic temperature compensation (ATC) functionality, eliminating manual temperature corrections and improving measurement accuracy across varying process temperatures.
Diagnostic Capabilities: Advanced Yokogawa transmitters provide electrode impedance monitoring and diagnostic alerts, enabling predictive maintenance strategies that prevent unexpected measurement failures and optimize calibration schedules.
Multi-Parameter Integration: The K9142TN integrates seamlessly into multi-parameter analytical systems, allowing simultaneous monitoring of pH, conductivity, dissolved oxygen, and other critical water quality parameters through unified control interfaces.
Customization Options: Yokogawa offers custom cable lengths, specialized mounting hardware, and application-specific electrode configurations to meet unique installation requirements. Contact technical support for custom engineering assistance.
Lead Time: Standard delivery within 3-5 business days for in-stock units. Custom configurations may require 2-3 weeks for manufacturing and quality verification.
Warranty Coverage: 12-month manufacturer warranty covering defects in materials and workmanship. Extended warranty programs available for critical applications requiring guaranteed uptime.
Technical Support: Access to Yokogawa-certified application engineers for installation guidance, troubleshooting assistance, and optimization recommendations. Support available via phone, email, and remote diagnostic tools.
Documentation Package: Each electrode ships with installation manual, calibration procedures, maintenance guidelines, and material compatibility charts. Digital documentation available for download including CAD drawings and compliance certificates.
What analyzers and transmitters are compatible with the K9142TN glass electrode?
The K9142TN features standard BNC connectivity, making it compatible with Yokogawa's FLXA series analyzers, pH transmitters with BNC inputs, and most third-party pH measurement instruments. For optimal performance and diagnostic capabilities, pair with Yokogawa FLXA21 or FLXA202 analyzers.
How often does the K9142TN electrode require calibration in continuous process applications?
Calibration frequency depends on process conditions and accuracy requirements. Typical industrial applications require calibration every 1-4 weeks. Stable processes with minimal fouling may extend to monthly calibration, while challenging applications with coating or extreme pH may require weekly verification. Implement regular calibration checks using pH 4, 7, and 10 buffer solutions.
Can this pH electrode handle high-temperature sterilization cycles in pharmaceutical applications?
The K9142TN operates reliably up to 100°C, suitable for many pharmaceutical processes. However, steam sterilization cycles exceeding 121°C require specialized high-temperature electrodes. For CIP (clean-in-place) and SIP (sterilize-in-place) applications, consult Yokogawa's sanitary electrode portfolio designed for autoclave conditions.
What maintenance procedures extend the operational lifespan of glass pH electrodes?
Proper storage in pH 4 buffer or electrode storage solution prevents glass membrane dehydration. Regular cleaning removes process coatings—use appropriate cleaning solutions based on fouling type (protein, oil, scale). Inspect the reference junction for blockage and refresh electrolyte as needed. Avoid mechanical shock and extreme temperature changes that can crack the glass membrane.
Does the K9142TN support remote monitoring and predictive maintenance strategies?
When connected to Yokogawa's smart analyzers with digital communication protocols (HART, Modbus, FOUNDATION Fieldbus), the K9142TN enables remote pH monitoring, electrode impedance diagnostics, and calibration history tracking. These capabilities support predictive maintenance programs that optimize electrode replacement timing and reduce unplanned downtime.
How does the double junction reference system improve electrode performance compared to single junction designs?
The double junction configuration isolates the internal Ag/AgCl reference from the process sample, preventing silver ion contamination in sensitive applications and reducing electrolyte depletion in high-temperature or aggressive chemical environments. This design extends electrode lifespan by 40-60% and maintains stable reference potential in challenging process conditions where single junction electrodes experience rapid drift.
Ready to upgrade your pH measurement infrastructure with proven Yokogawa technology? Contact our technical sales team for application-specific recommendations, system integration support, and competitive pricing on the K9142TN glass electrode. Our engineers can assess your process requirements and design complete analytical solutions that deliver reliable pH data for optimized process control.
© 2026 NINERMAS COMPANY LIMITED. All rights reserved.
Original Source: https://ninermas.com
Contact: sale@ninermas.com | +0086 187 5021 5667
Download PDF file here:
Click to Download PDF