The 1X01046H01L represents Emerson's commitment to zero-downtime power architecture for distributed control environments. This dual-output bulk power module transforms universal AC input into stable 12V and 24V DC rails, specifically engineered to energize DeltaV controllers, I/O subsystems, and field instrumentation across chemical processing, refining, pharmaceutical manufacturing, and water treatment facilities.
Designed for mission-critical applications where power interruption translates directly to production loss, the 1X01046H01L incorporates hot-swap capability, comprehensive fault protection, and conformal-coated circuitry to withstand corrosive industrial atmospheres. Its compact DIN-rail form factor optimizes cabinet space while delivering 120 watts of continuous power with better than 88% efficiency.
Whether you're building a new DeltaV installation or upgrading legacy power infrastructure, this module provides the reliability foundation that process automation demands. Certified to UL, CE, CSA, and ATEX Zone 2 standards, it meets global safety requirements for deployment in regulated industries worldwide.
→ Hot-Swappable Redundancy Architecture
Replace failed units without shutting down control systems. Maintenance windows become optional rather than mandatory, eliminating costly production interruptions and enabling predictive replacement strategies that reduce emergency callouts by up to 75%.
→ Universal Input Voltage Compatibility
Operates across 85-265 VAC range (47-63 Hz), accommodating international voltage standards and compensating for grid instability. Single part number simplifies global spare parts inventory and reduces procurement complexity for multi-site operations.
→ Simultaneous Dual-Voltage Output
Delivers both 12V DC (8A max) and 24V DC (4A max) from one compact module. Eliminates redundant power supplies in mixed-voltage installations, cutting cabinet space requirements by 40% and reducing wiring labor during commissioning.
✓ Extended Temperature Performance
Rated for -25°C to +70°C operation without forced cooling. Survives extreme ambient conditions in outdoor enclosures, desert climates, and high-temperature process areas where standard commercial power supplies fail within months.
✓ Multi-Layer Protection Circuitry
Integrated overvoltage, overcurrent, short-circuit, and thermal shutdown safeguards protect downstream equipment investments. Automatic recovery from fault conditions minimizes operator intervention and prevents cascade failures in distributed architectures.
✓ Front-Panel Diagnostic Indicators
LED status displays provide instant visual confirmation of power good, fault conditions, and load status. Technicians diagnose issues in seconds rather than minutes, reducing mean time to repair (MTTR) by 60% during troubleshooting activities.
Continuous Process Manufacturing
In 24/7 chemical reactors and distillation columns, the 1X01046H01L powers DeltaV MD controllers and analog I/O modules that regulate temperature, pressure, and flow variables. A petrochemical facility in Texas eliminated three unplanned shutdowns annually after implementing N+1 redundant power configurations, saving $2.1M in lost production value.
Batch Pharmaceutical Production
GMP-compliant drug manufacturing requires validated power systems with full traceability. This module's MTBF exceeding 200,000 hours and comprehensive certifications satisfy FDA 21 CFR Part 11 requirements while powering recipe-driven batch sequences through DeltaV Batch Executive software.
Water & Wastewater Treatment
Municipal treatment plants deploy the 1X01046H01L in outdoor NEMA-rated enclosures where humidity, temperature swings, and corrosive gases challenge electronics. Conformal coating and wide operating temperature range ensure reliable operation in pump stations, clarifiers, and disinfection systems.
Oil & Gas Upstream Production
Remote wellhead automation and separator control systems benefit from the module's ability to tolerate unstable generator power and extreme temperatures. ATEX Zone 2 certification permits installation in non-hazardous areas of facilities with occasional explosive atmosphere exposure.
Food & Beverage Processing
Breweries, dairy plants, and beverage bottling lines use the 1X01046H01L to power sanitary I/O systems monitoring CIP (clean-in-place) cycles, pasteurization temperatures, and packaging line speeds. Stainless steel mounting hardware and IP20 enclosure rating support washdown environments.
| Specification | Value |
|---|---|
| Catalog Number | 1X01046H01L |
| Output Voltage | 12 VDC ± 5% / 24 VDC ± 5% |
| Maximum Output Current | 12V: 8A | 24V: 4A |
| Total Power Capacity | 120W continuous, 150W peak (10 sec) |
| Input Voltage Range | 85-265 VAC, auto-ranging |
| Input Frequency | 47-63 Hz |
| Efficiency | ≥88% at rated load |
| Ripple & Noise | <150 mVp-p (20 MHz bandwidth) |
| Operating Temperature | -25°C to +70°C (derate above 50°C) |
| Storage Temperature | -40°C to +85°C |
| Humidity Range | 5-95% RH, non-condensing |
| Mounting Method | 35mm DIN rail (EN 50022) |
| Dimensions (H×W×D) | 125 × 120 × 85 mm (4.9" × 4.7" × 3.3") |
| Weight | 0.9 kg (2.0 lbs) |
| MTBF | >200,000 hours @ 25°C (MIL-HDBK-217F) |
| Safety Certifications | UL 508, CE, CSA C22.2, ATEX Zone 2 |
| EMC Compliance | EN 61000-6-2, EN 61000-6-4 |
Selection Guidelines:
Redundant Power Configuration
Pair two 1X01046H01L modules with ORing diodes or active redundancy controllers to create fault-tolerant N+1 architectures. Load-sharing circuitry automatically balances current draw, while seamless failover occurs within 20 milliseconds—faster than most control systems' scan cycles—ensuring zero process disruption during power supply failures.
Remote Monitoring Integration
Connect diagnostic outputs to DeltaV digital input modules for real-time power system health monitoring. Integrate status signals into AMS Device Manager for predictive maintenance alerts based on output voltage drift, temperature rise, or load imbalance trends detected over time.
Customized Output Configurations
For specialized applications requiring non-standard voltages, Emerson offers factory-configured variants with 5V, 15V, or 48V outputs. Consult application engineering for minimum order quantities and lead times on custom voltage specifications.
Standard Lead Time: 3-5 business days for in-stock units; expedited same-day shipping available for critical outages
Custom Configurations: 4-6 weeks for factory-programmed voltage variants or special certifications
Warranty Coverage: 12 months from shipment date, covering material defects and workmanship failures
Technical Support: Lifetime application assistance via phone, email, and remote diagnostics
Documentation Package: Installation manual, wiring diagrams, CAD drawings (DWG/STEP), and test certificates included
Extended warranty programs and preventive maintenance contracts available for facilities requiring guaranteed uptime SLAs. Our field service engineers provide on-site commissioning support, power quality audits, and thermal imaging surveys to optimize system reliability.
What is the recommended redundancy strategy for critical control systems?
Implement N+1 configuration using two 1X01046H01L modules with ORing diodes. This provides full load capacity during single-unit failure while enabling hot-swap maintenance. For SIL 3 applications, consider 2oo3 (two-out-of-three) voting architectures with independent power distribution paths.
How does this module perform in high-vibration environments?
The 1X01046H01L withstands 2G vibration (10-150 Hz) and 15G shock per IEC 60068-2-6. All internal components use locking connectors and potted assemblies. For severe vibration (offshore platforms, mobile equipment), add supplemental DIN-rail locking clips and verify mounting torque quarterly.
Can I parallel multiple units to increase current capacity?
Yes, but only with active current-sharing controllers or ORing diodes to prevent reverse current flow. Simple parallel connection without load-balancing circuitry will cause unequal current distribution and premature failure of the higher-output unit. Consult factory application notes for proper paralleling schematics.
What maintenance schedule should I follow?
Quarterly: Inspect terminal tightness (re-torque to 0.5 Nm), clean ventilation slots, verify LED indicators
Annually: Measure output voltages under load, check ripple with oscilloscope, thermal imaging scan
5-7 Years: Electrolytic capacitor replacement (temperature-dependent); factory refurbishment services available
Is this compatible with legacy DeltaV hardware from the 1990s?
Full backward compatibility confirmed with DeltaV systems running version 6.3 and later, including original S-series controllers and I/O carriers. The 1X01046H01L directly replaces obsolete power supplies (part numbers 1X00024H01, 1X00416H01) without firmware updates or configuration changes.
How do I troubleshoot a fault condition indicated by the red LED?
Red LED indicates overcurrent, overvoltage, or thermal shutdown. Immediate steps: (1) Disconnect load and verify fault clears, (2) Measure output voltage with no load—should be 12V ±0.6V and 24V ±1.2V, (3) Inspect wiring for shorts or ground faults, (4) Check ambient temperature <70°C. If fault persists with no load, unit requires factory service or replacement.
Secure your process control infrastructure with proven Emerson DeltaV power technology trusted by Fortune 500 manufacturers worldwide. Every 1X01046H01L ships with comprehensive documentation, factory test certificates, and our commitment to rapid technical support when you need it most.
Contact our automation specialists for application-specific sizing assistance, redundancy architecture design, or volume pricing for multi-site deployments. We maintain strategic inventory across North America, Europe, and Asia-Pacific to support your project timelines.
© 2026 NINERMAS COMPANY LIMITED. All rights reserved.
Original Source: https://ninermas.com
Contact: sale@ninermas.com | +0086 187 5021 5667