The CE4002S1T2B5 is an industrial-grade termination assembly engineered for Emerson DeltaV M-series control systems, enabling secure field wiring connections for 32-channel discrete output cards operating at 24VDC high-side switching. Designed for mission-critical process automation environments, this termination block delivers reliable signal routing for solenoid valve banks, motor contactors, annunciator panels, and safety interlock circuits across refining, petrochemical, pharmaceutical manufacturing, and power generation facilities.
→ High-Density Channel Architecture: Supports 32 independent output channels within a compact footprint, reducing panel space requirements by up to 40% compared to legacy terminal designs while maintaining full electrical isolation (1000VDC tested) between channels and system ground.
→ Robust Current Handling: Each channel delivers 100mA continuous output current with 3.2A aggregate card capacity, sufficient for driving industrial pilot relays, LED indicators, and low-power actuators without external amplification.
→ Keyed Installation Protection: B4 mechanical keying system prevents incorrect I/O card insertion, eliminating costly wiring errors and reducing commissioning time by 25-30% through foolproof module-to-carrier alignment.
→ Hazardous Area Certification: ATEX Zone 2 (II 3G EEx nA IIC T4) and FM Class I Division 2 approvals enable deployment in explosive atmosphere locations without additional barriers, expanding application versatility.
✓ Extended Temperature Range: Series 2 Plus variants operate from -40°C to +70°C, supporting outdoor installations and extreme climate deployments.
✓ Conformal Coating Protection: ISA-S71.04 Class G3 environmental rating ensures reliable operation in corrosive gas environments typical of chemical processing and offshore platforms.
Oil & Gas Production Facilities:
Controls wellhead valve manifolds and separator level alarms in offshore platforms where space constraints demand high-density I/O solutions. The optical isolation prevents ground loop interference common in electrically noisy drilling environments, while ATEX certification permits installation in Zone 2 classified areas without costly explosion-proof enclosures.
Pharmaceutical Batch Processing:
Manages clean-in-place (CIP) valve sequencing and reactor agitator interlocks in FDA-regulated manufacturing. The termination block's conformal coating resists sanitizing chemical vapors, and the keyed design ensures validation-compliant installation that survives regulatory audits.
Power Generation Turbine Control:
Interfaces with combustion turbine auxiliary systems including lube oil pump starters, cooling fan contactors, and alarm annunciators. The -40°C to +70°C operating range accommodates outdoor switchgear installations, while 10g shock resistance withstands vibration from rotating machinery.
Chemical Reactor Safety Systems:
Provides hardwired outputs for emergency shutdown solenoids and interlock relays in SIL-rated safety instrumented systems. The 1000VDC isolation barrier meets IEC 61511 separation requirements between BPCS and SIS layers.
Water Treatment SCADA Networks:
Drives remote pump station motor starters and chlorination system dosing valves across distributed municipal infrastructure. The IP20/NEMA 12 rating suits indoor control room environments, while the DIN-rail mounting simplifies retrofit installations.
| Parameter | Specification | Selection Notes |
|---|---|---|
| Channel Count | 32 discrete outputs | Choose for high-density applications; use 16-ch variants for lower point counts |
| Output Type | 24VDC high-side switching | Requires common return; verify field device compatibility |
| Current Rating | 100mA/channel, 3.2A card total | Suitable for pilot relays ≤5W; use relay modules for higher loads |
| Isolation Voltage | 1000VDC channel-to-system | Meets SIL 2 separation requirements per IEC 61511 |
| Operating Temp | 0°C to +60°C (std) -40°C to +70°C (S2+) | Specify Series 2 Plus for outdoor/extreme environments |
| Keying Code | B4 (6-position mechanical) | Must match I/O card keying; prevents cross-installation |
| Hazloc Rating | ATEX Zone 2, FM Div 2 | Permits installation in classified areas without barriers |
| Dimensions (HxWxD) | 107 x 41 x 105 mm | Verify panel depth clearance for carrier + termination assembly |
| Wire Termination | 32-position screw clamp | Accepts 14-22 AWG; torque to 0.5 Nm per manufacturer spec |
| LocalBus Draw | 100mA typ, 150mA max @ 12VDC | Factor into carrier power budget calculations |
Selection Guidelines: Verify that field device current draw remains below 100mA per channel to prevent output transistor damage. For loads exceeding this threshold, specify fused termination variants (CE4002S1T2B2) or external relay interfaces. Confirm that your M-series carrier supports the B4 keying configuration before ordering.
Hot-Swap Capability: The termination block supports online I/O card replacement without process shutdown, enabling maintenance during production runs. The carrier's retention mechanism maintains field wiring connections while the card is extracted, reducing mean time to repair (MTTR) by 60% compared to fixed-terminal designs.
Diagnostic LED Indicators: Per-channel status LEDs provide instant visual confirmation of output states during commissioning and troubleshooting, eliminating the need for multimeter probing in densely packed panels.
DeltaV Integration: Seamless compatibility with DeltaV Operate HMI and Control Studio engineering environment enables drag-and-drop I/O assignment, automatic channel mapping, and real-time diagnostics through the DeltaV Explorer interface.
| Service Element | Standard Offering |
|---|---|
| Stock Availability | In-stock units ship within 24-48 hours; custom configurations 5-7 business days |
| Warranty Coverage | 12-month manufacturer defect warranty; extended coverage available |
| Technical Support | Pre-sales application engineering, post-sales troubleshooting via email/phone |
| Documentation Package | Installation manual, wiring diagrams, dimensional drawings, test certificates |
| Shipping Options | DHL/FedEx express (3-5 days global), economy freight (7-14 days), white-glove available |
Q: Can the CE4002S1T2B5 termination block interface with third-party DCS systems outside the DeltaV family?
A: No, this termination block is mechanically and electrically designed exclusively for Emerson DeltaV M-series I/O carriers and cards. The B4 keying and LocalBus protocol are proprietary to the DeltaV architecture. For non-DeltaV systems, consult your DCS vendor's I/O catalog.
Q: What is the maximum cable run distance from the termination block to field devices for 24VDC discrete outputs?
A: Maximum recommended distance is 300 meters (1000 feet) using 18 AWG shielded cable, assuming ≤5% voltage drop at 100mA load. For longer runs, use 16 AWG wire or local relay amplification to maintain signal integrity and prevent nuisance trips.
Q: Does this terminal block provide short-circuit protection for individual output channels?
A: The standard CE4002S1T2B5 includes electronic current limiting but not per-channel fusing. For applications requiring individual circuit protection (e.g., SIL-rated systems), specify the fused variant CE4002S1T2B2 which incorporates replaceable 200mA fuses per channel.
Q: How does the high-side switching configuration affect field wiring compared to low-side outputs?
A: High-side switching supplies +24VDC to the load, with the field device return connected to common ground. This configuration simplifies troubleshooting (grounded faults don't energize outputs) but requires that all field devices share a common negative rail. Verify your valve/relay coil wiring matches this topology.
Q: Can I mix different termination block models on the same M-series carrier?
A: Yes, M-series horizontal carriers support mixed I/O configurations. However, each termination block must match its corresponding I/O card's keying code. The carrier's slot-specific keying prevents incorrect pairings, but verify your system design allocates appropriate power budget for the combined LocalBus draw.
Q: What environmental conditions void the warranty or reduce service life?
A: Operating beyond -40°C to +70°C (Series 2 Plus) or 0°C to +60°C (standard), exposure to condensing humidity above 95% RH, or airborne contaminants exceeding ISA-S71.04 Class G3 limits will degrade performance. Conformal coating provides chemical resistance, but direct liquid contact or submersion is not supported.
Our DeltaV-certified application engineers provide complimentary pre-sales support including I/O point mapping, power budget calculations, and hazardous area classification reviews. Contact our team to discuss your project requirements, request CAD drawings, or obtain formal quotations for multi-unit orders.
Ready to Optimize Your DeltaV I/O Architecture?
Email sale@ninermas.com or call +0086 187 5021 5667 for same-day quotations and technical datasheets.
© 2026 NINERMAS COMPANY LIMITED. All rights reserved.
Original Source: https://ninermas.com
Contact: sale@ninermas.com | +0086 187 5021 5667
Download PDF file here:
Click to Download PDF