The ABB REG670 1MRK002826-AC represents a comprehensive protection and control solution specifically designed for synchronous generators, motors, and rotating machinery in power generation facilities. This industrial-grade relay integrates advanced protection algorithms, real-time diagnostics, and seamless communication capabilities to ensure maximum uptime while preventing catastrophic equipment failures in mission-critical applications.
Built for utility-scale power plants, industrial cogeneration systems, and distributed energy resources, the REG670 delivers multi-layered fault detection with sub-cycle response times. Its modular architecture supports both standalone operation and networked deployment across complex power generation infrastructures.
Whether you're protecting a 500 MW turbine generator in a combined-cycle plant or managing backup generation for critical facilities, the REG670 1MRK002826-AC provides the reliability, precision, and flexibility demanded by modern power systems. With native IEC 61850 support and backward compatibility with legacy protocols, this relay bridges the gap between traditional protection schemes and smart grid requirements.
→ Multi-Function Protection Suite
Integrates 30+ protection elements including differential (87G), overcurrent (50/51), loss of excitation (40), reverse power (32), stator/rotor ground fault (64G/64R), and frequency protection (81O/U) in a single compact unit, reducing installation complexity and panel footprint by 65% compared to discrete relay systems.
→ Advanced Condition Monitoring
Continuous tracking of insulation resistance degradation, thermal stress patterns, and operational anomalies enables predictive maintenance strategies that reduce unplanned outages by up to 40% and extend generator service life through early fault detection.
→ Universal Communication Architecture
Native support for IEC 61850 (MMS, GOOSE), Modbus RTU/TCP, DNP3, and IEC 60870-5-103 ensures seamless integration with SCADA platforms, historian systems, and plant automation networks without requiring protocol converters or gateways.
→ Adaptive Protection Logic
Configurable setting groups automatically adjust protection thresholds based on operational states (startup, synchronization, normal load, shutdown), optimizing sensitivity during transient conditions while eliminating nuisance trips during routine operations.
→ Revenue-Grade Metering
Class 0.2S measurement accuracy meets utility billing standards, allowing the relay to serve dual purposes as both protection device and revenue meter, eliminating the need for separate metering equipment in generator interconnection applications.
→ Harsh Environment Resilience
Operates reliably across -40°C to +70°C temperature range with immunity to electromagnetic interference, making it suitable for offshore platforms, desert installations, arctic facilities, and industrial environments with high electrical noise.
✓ Utility-Scale Power Generation
Protects steam, gas, and hydro turbine generators ranging from 10 MVA to 1000+ MVA in central power stations. Coordinates with transformer protection, bus protection, and transmission line relays to provide zone-selective fault isolation that maintains grid stability during disturbances.
✓ Industrial Cogeneration & CHP Systems
Monitors combined heat and power installations in refineries, chemical plants, pulp mills, and manufacturing facilities where process steam and electrical generation are integrated. Handles complex operating modes including grid-parallel, islanded, and black-start scenarios.
✓ Renewable Energy Hybrid Systems
Manages protection coordination for biomass generators, biogas engines, and waste-to-energy facilities that interface with solar PV and battery storage systems, ensuring stable operation during variable renewable output and load transitions.
✓ Marine & Offshore Power Systems
Provides reliable protection for shipboard generators, FPSO power plants, and offshore platform generation equipment operating in corrosive saltwater environments with constant vibration and temperature cycling.
✓ Mission-Critical Backup Generation
Safeguards emergency diesel generators and gas turbine sets serving data centers, hospitals, telecommunications facilities, and financial institutions where power continuity directly impacts operational revenue and safety.
| Parameter | Specification |
|---|---|
| Model Designation | 1MRK002826-AC |
| Product Family | ABB REG670 Series |
| Protection Functions | Differential (87G), Overcurrent (50/51/51V), Overvoltage (59), Undervoltage (27), Reverse Power (32), Loss of Excitation (40), Stator Ground Fault (64G), Rotor Ground Fault (64R), Frequency (81O/U), Negative Sequence (46) |
| Measurement Accuracy | Class 0.2S (revenue metering compliant) |
| Communication Interfaces | IEC 61850 (Ed. 2), Modbus RTU/TCP, DNP3, IEC 60870-5-103 |
| Auxiliary Power Supply | 110-250V DC / 100-240V AC (±20%) |
| Operating Temperature | -40°C to +70°C (-40°F to +158°F) |
| Display Interface | Graphical LCD with integrated local HMI |
| Standards Compliance | IEC 60255, IEEE C37.90, ANSI C37.102 |
| Mounting Configuration | Panel mount / 19" rack mount |
Selection Criteria: When specifying the REG670 for your application, consider generator MVA rating, voltage class (medium vs. high voltage), required communication protocols, and whether revenue metering functionality is needed. For generators above 100 MVA or applications requiring redundant protection, consider deploying dual REG670 units in primary/backup configuration. Consult with our application engineers to validate CT/VT ratios and protection coordination with upstream/downstream devices.
IoT & Cloud Connectivity: The REG670 supports secure data export to cloud-based analytics platforms via OPC UA and MQTT protocols, enabling remote diagnostics, fleet-wide performance benchmarking, and AI-driven anomaly detection across distributed generation portfolios.
Cybersecurity Features: Built-in role-based access control (RBAC), encrypted communication channels, and audit logging comply with NERC CIP requirements for critical infrastructure protection, ensuring secure operation in networked environments.
Customization Options: Factory configuration services available for pre-programmed protection settings, custom logic equations, and application-specific HMI screens. Field-upgradable firmware ensures long-term adaptability to evolving grid codes and operational requirements.
Standard Lead Time: 3-5 business days for in-stock units; 4-6 weeks for factory-configured custom orders with specialized I/O modules or communication cards.
Warranty Coverage: Comprehensive 12-month manufacturer warranty covering defects in materials, workmanship, and firmware. Extended warranty programs available for critical applications requiring 3-5 year coverage.
Technical Support: Lifetime access to our protection engineering team for commissioning assistance, settings calculation, fault analysis, and troubleshooting. Remote support available via secure VPN connection for urgent issues.
Documentation Package: Each relay ships with installation manual, protection settings guide, communication configuration templates, PCM600 software license, and IEC 61850 ICD files for SCADA integration.
Q: How does the REG670 handle generator startup transients without false tripping?
A: The relay employs adaptive setting groups that automatically increase pickup thresholds during startup sequences. The loss of excitation (40) and reverse power (32) functions include configurable time delays and voltage-dependent characteristics that distinguish between normal startup conditions and genuine fault scenarios.
Q: What is the maximum generator capacity this relay can protect?
A: The REG670 is suitable for generators ranging from 1 MVA to over 1000 MVA. Protection coverage is determined by CT/VT ratios and relay settings rather than absolute generator size. For very large units, dual relay configurations provide redundancy and meet regulatory requirements.
Q: Can the relay interface with existing DCS or PLC control systems?
A: Yes, through multiple pathways. Hardwired binary inputs/outputs provide direct I/O integration, while Modbus TCP/RTU enables register-based data exchange with PLCs. For DCS integration, IEC 61850 MMS or DNP3 protocols offer comprehensive data modeling and event reporting.
Q: How is differential protection configured for generators with multiple neutral grounding methods?
A: The 87G function supports high-impedance, low-impedance, and ungrounded neutral configurations. Settings include adjustable slope characteristics, harmonic restraint (2nd/5th harmonics), and CT saturation detection to maintain stability during external faults while ensuring fast operation for internal winding faults.
Q: What commissioning tools are required for relay setup and testing?
A: ABB's PCM600 software (included) handles all configuration, settings management, and disturbance record analysis. For functional testing, a secondary injection test set capable of multi-phase voltage/current injection is recommended. Typical commissioning requires 4-6 hours including CT polarity verification and protection validation.
Q: Does the relay support islanded microgrid operation?
A: Absolutely. The REG670 includes dedicated islanding detection, frequency/voltage monitoring (81O/U, 27/59), and synchronization check (25) functions essential for safe grid separation and reconnection. Configurable load-shedding logic supports frequency stabilization during islanded operation.
Contact our protection specialists today for application-specific guidance, protection coordination studies, and competitive pricing on the ABB REG670 1MRK002826-AC. Our team provides comprehensive support from initial specification through commissioning and lifecycle maintenance.
Request a Quote: Email your generator nameplate data, single-line diagram, and protection requirements to our engineering team for a detailed proposal within 24 hours.
Technical Consultation: Schedule a complimentary 30-minute consultation to discuss protection philosophy, settings coordination, and integration with existing substation automation systems.