The ABB REA101 is a precision neutral voltage displacement relay engineered for earth fault detection and protection in ungrounded (isolated neutral) and compensated power distribution systems. Utilizing advanced 59N (neutral overvoltage) protection logic combined with directional sensing capability, it delivers reliable ground fault identification while minimizing nuisance tripping in industrial, utility, and critical infrastructure applications.
Designed for medium-voltage switchgear, generator protection panels, and substation control systems, the REA101 addresses challenges such as intermittent ground faults, insulation degradation monitoring, and system unbalance detection in networks where traditional overcurrent protection is ineffective. It is widely deployed in power generation facilities, chemical plants, mining operations, marine installations, and renewable energy systems requiring continuous operation during single-phase ground faults.
As part of the ABB Relion® protection family, the REA101 integrates seamlessly with modern SCADA systems and substation automation architectures. It offers configurable alarm thresholds, directional discrimination, and comprehensive event logging, making it ideal for consulting engineers, panel builders, system integrators, and end-user maintenance teams. Contact our protection engineering team for application-specific configuration guidance and technical documentation.
The REA101 is engineered for installations demanding high reliability and selective earth fault protection, particularly in:
To facilitate engineering design and procurement, we provide standardized configurations with customization options for project-specific requirements:
| Parameter | Specification |
|---|---|
| Rated Voltage (U0) | 100V / 110V / 115V / 120V AC (50/60Hz), configurable |
| Voltage Setting Range | 5% – 100% of U0, adjustable in 1% steps |
| Directional Element | 3I0 input: 1A or 5A nominal, sensitivity 0.02–10A |
| Operating Time | Definite: 0.05–300s; Inverse: IEC 60255 curves |
| Auxiliary Supply | 24–250V DC / 110–240V AC, universal input |
| Contact Outputs | 4× SPDT (Form C), 5A @ 250V AC resistive |
| Communication | RS-485 Modbus RTU (standard); IEC 61850 (optional) |
| Mounting | Panel flush-mount (96×96mm cutout) or DIN rail adapter |
| Protection Class | IP54 front / IP20 terminals (panel-mounted) |
| Operating Temp. | -25°C to +70°C, storage -40°C to +85°C |
| Compliance | IEC 60255-1/-27, IEC 61000-4 (EMC), CE marked |
Selection Considerations: When specifying the REA101, engineers should confirm: (1) system nominal voltage and grounding method (ungrounded/resistance/reactance grounded), (2) VT/CT ratios and burden capacity, (3) required protection coordination with existing relays, (4) communication protocol for SCADA integration, and (5) environmental conditions (temperature, humidity, vibration). Our application engineers can review single-line diagrams and provide relay setting calculations upon request.
Lead Time: Standard catalog models ship within 3–5 business days from regional stock (Asia-Pacific/EMEA/Americas warehouses). Custom-configured units with specific firmware, labeling, or factory acceptance testing require 2–3 weeks.
Warranty & Service: All units include a 24-month manufacturer warranty covering defects in materials and workmanship. Extended warranty and preventive maintenance contracts available. Technical support includes remote diagnostics assistance, firmware updates, and access to ABB's global service network.
Documentation Package: Each relay ships with: installation manual (multi-language), electrical connection diagrams, protection setting worksheets, Modbus register map, IEC 61850 ICD file (if applicable), and factory test certificate traceable to ISO/IEC 17025 accredited lab.
Commissioning Support: On-site commissioning services available in major markets, including relay injection testing (using Omicron/Doble test sets), CT polarity verification, SCADA point mapping, and operator training. Remote commissioning via secure VPN also supported for experienced integrators.
Q: How does the REA101 neutral voltage displacement relay interface with existing protection panels?
A: The relay accepts standard VT secondary voltages (typically 100–120V from open-delta or broken-delta connection) and optional 3I0 current input from core-balance CT or residual connection of phase CTs. It outputs via volt-free contacts for trip/alarm circuits and communicates via RS-485 or Ethernet. Confirm VT/CT ratios, burden capacity, and wiring polarity during engineering phase.
Q: What is the maximum number of feeders one REA101 can protect?
A: Each REA101 unit protects a single feeder or zone. For multi-feeder selectivity in compensated networks, deploy one relay per outgoing circuit with directional elements enabled, coordinated via communication-based interlocking or time-graded settings. Centralized schemes using busbar VT and individual feeder CTs are also feasible.
Q: What level of energy savings or fault detection improvement can be expected?
A: While the relay itself does not directly reduce energy consumption, it prevents costly unplanned outages (estimated at $10,000–$500,000/hour in process industries) by enabling predictive maintenance through insulation monitoring. Early fault detection can reduce equipment damage repair costs by 40–60% compared to reactive maintenance strategies.
Q: What are the environmental and installation requirements?
A: The relay operates in -25°C to +70°C ambient, up to 95% RH non-condensing, and withstands IEC 60255-21-1 Class 2 vibration. Panel cutout is 92×92mm (96×96mm models) with minimum 150mm depth behind panel. Ensure adequate ventilation (no forced cooling required) and separation from high-current busbars per IEC 61439 clearance rules.
Q: Does the REA101 support remote monitoring and data acquisition?
A: Yes. Standard models include Modbus RTU over RS-485 (up to 115.2 kbps, 32 devices per segment). Optional IEC 61850 variants provide MMS/GOOSE messaging for substation automation, with DNP3 available on request. All models log up to 100 fault events with waveform capture (voltage/current snapshots) retrievable via front port or network.
Q: Can the relay be used in systems with Petersen coil (arc suppression coil) grounding?
A: Absolutely. The REA101 is specifically designed for compensated networks. Its directional element and harmonic filtering effectively discriminate between capacitive charging currents and resistive fault currents, even when the coil is tuned to near-perfect compensation. Coordinate settings with coil tuning range and system capacitance calculations.
For detailed application engineering, relay setting coordination studies, or project-specific pricing, please provide our team with: (1) system single-line diagram, (2) nominal voltage and grounding configuration, (3) VT/CT specifications and ratios, (4) existing protection relay schedule, (5) SCADA/communication requirements, and (6) quantity and delivery timeline. Our protection specialists will respond within 24 hours with tailored recommendations and budget proposals.
© 2026 NINERMAS COMPANY LIMITED. All rights reserved. Original Source: https://ninermas.com Contact: sale@ninermas.com | +0086 187 5021 5667