The ABB CM582-DP (Part No. 1SAP172200R0001) delivers robust PROFIBUS DP slave functionality for AC500 programmable logic controllers, enabling distributed automation architectures to leverage proven fieldbus technology. This compact communication interface bridges AC500 PLCs with PROFIBUS DP networks, supporting real-time data exchange at speeds up to 12 Mbps while maintaining deterministic performance critical for industrial process control.
Engineered for manufacturing environments demanding reliable multi-vendor interoperability, the CM582-DP transforms AC500 controllers into intelligent network nodes capable of cyclic data exchange and acyclic parameter services. Whether integrating machine-level controllers into supervisory SCADA systems or connecting distributed control zones across factory floors, this module provides the standardized communication backbone required for modern automation infrastructure.
With IP20 protection, galvanically isolated RS485 interface, and hot-swappable design, the CM582-DP minimizes installation complexity while maximizing operational flexibility. Factory-tested PROFIBUS conformance ensures seamless compatibility with third-party devices, reducing commissioning time and long-term maintenance overhead.
→ High-Speed Deterministic Communication
Supports PROFIBUS DP V0/V1/V2 protocols with automatic baud rate detection from 9.6 kbps to 12 Mbps. Handles up to 244 bytes input/output data per cycle, accommodating complex data structures for advanced applications. Watchdog timeout monitoring ensures network integrity.
→ Simplified System Integration
Direct backplane mounting on AC500 PLCs occupies single slot position. GSD file support in ABB Automation Builder streamlines master configuration. Auto-detection eliminates manual speed settings during commissioning, reducing setup errors.
→ Industrial-Grade Reliability
Operates across 0°C to +55°C temperature range with 5-95% humidity tolerance. Galvanic isolation protects against ground loops and electrical noise. Diagnostic LEDs provide instant visual status for power, bus activity, and fault conditions.
→ Compact & Maintainable Design
62×28×135mm footprint conserves control cabinet space. Weighs only 94 grams for easy handling. Hot-swappable capability enables module replacement during operation in redundant configurations. Field-upgradeable firmware ensures long-term compatibility.
✓ Comprehensive Diagnostics
Built-in monitoring reports communication errors, configuration mismatches, and network topology issues via PLC program variables. Bus fault detection and master timeout alerts enable proactive maintenance.
✓ Environmental Compliance
RoHS 2011/65/EU + Amendment 2015/863 compliant. REACH regulation conformity. WEEE Category 5 classification for responsible end-of-life disposal.
Automotive Assembly Lines
Deploy AC500 PLCs as zone controllers managing robotic welding cells, conveyor systems, and quality inspection stations. The CM582-DP enables each controller to report production counts, cycle times, and alarm conditions to line supervisors via PROFIBUS while receiving recipe changes and maintenance commands. Deterministic communication ensures synchronized operations across multi-station assembly processes.
Chemical Process Control
Implement distributed control strategies where AC500 PLCs handle local PID loops for reactor temperature, pressure regulation, and flow metering. The module connects these field controllers to centralized DCS systems, supporting both cyclic process data exchange and acyclic parameter downloads for batch recipe management. 12 Mbps throughput accommodates high-frequency sampling requirements.
Packaging Machinery Networks
Integrate multiple packaging machines into unified production lines where each AC500 controller manages filling, sealing, labeling, or palletizing operations. PROFIBUS connectivity via CM582-DP allows centralized HMI systems to monitor overall equipment effectiveness (OEE), adjust speed setpoints, and coordinate material flow between stations.
Water Treatment Facilities
Connect remote pump stations, filtration systems, and chemical dosing units across distributed sites. AC500 PLCs equipped with CM582-DP modules function as autonomous local controllers while communicating operational status, flow totals, and alarm conditions to central SCADA systems via PROFIBUS networks spanning multiple kilometers using RS485 repeaters.
Building HVAC Systems
Bridge proprietary HVAC equipment protocols to standardized building management systems (BMS). AC500 PLCs with CM582-DP modules serve as intelligent gateways, translating between local equipment interfaces and PROFIBUS-based BMS networks for centralized energy monitoring and climate control optimization.
| Parameter | Specification |
|---|---|
| Model Designation | CM582-DP |
| Manufacturer Part Number | 1SAP172200R0001 |
| EAN Barcode | 4016779878265 |
| Product Series | AC500 Communication Modules |
| Network Function | PROFIBUS DP Slave Interface |
| Physical Interface | RS485 Serial (9-pin D-sub connector) |
| Transmission Speed | 9.6 kbps to 12 Mbps (auto-detect) |
| Protocol Versions | PROFIBUS DP V0, V1, V2 |
| Data Capacity | 244 bytes input / 244 bytes output per cycle |
| Station Address Range | 1-125 (configurable) |
| Enclosure Rating | IP20 (control cabinet mounting) |
| Dimensions (D×W×H) | 62mm × 28mm × 135mm |
| Module Weight | 0.094 kg |
| Operating Temperature | 0°C to +55°C |
| Storage Temperature | -25°C to +70°C |
| Humidity Tolerance | 5% to 95% RH (non-condensing) |
| Power Supply | Via AC500 backplane (~1.5W typical) |
| Isolation | Galvanic isolation between RS485 and backplane |
| Certifications | CE, UL/cUL, IEC 61131-2, PROFIBUS certified |
| Country of Origin | Switzerland |
Selection Criteria: Choose the CM582-DP when your application requires AC500 PLCs to function as PROFIBUS slaves within existing networks controlled by SCADA systems or higher-level PLCs. For master functionality where the AC500 must control PROFIBUS slave devices, consider alternative ABB master modules. Verify that your PROFIBUS master supports DP V0/V1/V2 protocols and can accommodate the module's 244-byte data capacity.
IoT & Industry 4.0 Readiness
When combined with AC500 PLCs featuring Ethernet communication modules, the CM582-DP enables hybrid architectures bridging legacy PROFIBUS networks with modern Industrial Ethernet protocols. This facilitates gradual migration strategies where existing fieldbus infrastructure remains operational while new cloud connectivity and data analytics capabilities are added incrementally.
Redundancy Support
In critical applications requiring high availability, deploy CM582-DP modules in redundant AC500 configurations. The hot-swappable design allows module replacement during operation without disrupting other system components, minimizing unplanned downtime.
Custom Data Mapping
ABB Automation Builder software provides flexible data mapping tools, allowing engineers to define custom relationships between PLC program variables and PROFIBUS data objects. This enables optimized data structures tailored to specific application requirements, reducing network overhead and improving response times.
Standard Delivery: In-stock CM582-DP modules ship within 1-3 business days via express courier services. International shipments include full customs documentation and HS code classification (8537.10.99) for streamlined clearance.
Warranty Coverage: 12-month manufacturer warranty covers defects in materials and workmanship. Extended warranty options available for critical infrastructure applications requiring long-term support commitments.
Technical Support: Pre-sales consultation assists with system architecture design, network topology planning, and compatibility verification. Post-sales support includes configuration assistance, troubleshooting guidance, and firmware update coordination.
Documentation Package: Each module ships with installation quick-start guide, GSD configuration file for PROFIBUS master setup, dimensional drawings for panel layout, and wiring diagrams. Complete technical manuals available for download from ABB Library.
How do I configure the CM582-DP station address for PROFIBUS network integration?
Station address configuration is performed through ABB Automation Builder software after importing the module's GSD file. Navigate to the PROFIBUS network configuration section, select the CM582-DP device, and assign an address between 1-125 that doesn't conflict with existing network nodes. The address is stored in non-volatile memory and persists through power cycles.
What data throughput can I expect with 244-byte input/output capacity?
At 12 Mbps with typical PROFIBUS DP cycle times of 5-10ms, the module supports approximately 100-200 data exchanges per second. Actual throughput depends on network load, master scan rates, and the number of active slaves. For applications requiring higher data volumes, consider segmenting data across multiple communication cycles or implementing data compression strategies in the PLC program.
Does the CM582-DP support PROFIBUS PA devices for process automation?
No, the CM582-DP is designed exclusively for PROFIBUS DP networks using RS485 physical layer. For PROFIBUS PA applications requiring intrinsically safe field devices and bus-powered sensors, you'll need a DP/PA coupler or link device to bridge between the DP network and PA segments.
Can I install multiple CM582-DP modules in a single AC500 PLC?
Yes, AC500 PLCs support multiple communication modules depending on the base unit model and available backplane slots. Each CM582-DP occupies one slot and can connect to a separate PROFIBUS network, enabling multi-network architectures or redundant communication paths. Consult the AC500 hardware manual for maximum module counts and slot allocation rules.
What diagnostic capabilities help troubleshoot PROFIBUS communication issues?
The module provides three-color LED indicators showing power status (green), bus activity (flashing green during data exchange), and fault conditions (red for configuration errors or bus failures). Software diagnostics accessible via PLC program variables include communication error counters, master timeout events, configuration mismatch alerts, and real-time bus statistics. These metrics enable proactive identification of cabling issues, termination problems, or network congestion.
How does galvanic isolation protect my control system?
The RS485 interface is electrically isolated from the AC500 backplane using optocouplers and isolated DC-DC converters. This prevents ground potential differences between networked devices from causing circulating currents that could damage equipment or introduce noise into control signals. Isolation is particularly critical in distributed systems where PROFIBUS cables span multiple buildings or connect equipment with separate power sources.
Contact our automation specialists to discuss your distributed control architecture requirements. We'll help you determine optimal network topology, verify compatibility with existing infrastructure, and provide configuration guidance for seamless AC500 integration. Request a technical consultation or place your order today to enhance your automation network capabilities.
Email: sale@ninermas.com
Phone: +0086 187 5021 5667
Business Hours: Monday-Friday, 9:00 AM - 6:00 PM CST