The ABB 1SDA072312R1 represents a factory-certified moving assembly engineered for SACE Emax 2 E2.2S 1250 Ekip Dip LSI 3-pole WMP circuit breakers. This precision-machined component delivers the mechanical reliability required for high-capacity switching operations in mission-critical power distribution environments.
Designed for industrial facilities managing heavy electrical loads, this OEM replacement part addresses the operational demands of manufacturing plants, data centers, and commercial infrastructure where circuit breaker downtime translates directly to production losses. The component maintains ABB's stringent mechanical tolerances, ensuring consistent performance across thousands of switching cycles.
Whether you're executing preventive maintenance schedules or responding to component wear in aging installations, the 1SDA072312R1 provides a direct-fit solution that restores breaker functionality to factory specifications without requiring complete unit replacement.
✓ OEM-Certified Construction
Authentic ABB engineering ensures dimensional accuracy and material specifications that match original equipment standards, eliminating compatibility risks associated with aftermarket alternatives.
✓ High-Cycle Durability
Robust mechanical design withstands repetitive thermal expansion and mechanical stress inherent in fault-clearing operations, extending service intervals and reducing lifecycle costs.
✓ Precision Alignment System
Factory-calibrated tolerances guarantee proper contact engagement and arc chamber positioning, critical for maintaining interrupting capacity and personnel safety.
✓ Thermal Stress Resistance
Engineered materials maintain structural integrity under high-current fault conditions, preventing deformation that could compromise switching reliability.
✓ Streamlined Maintenance Integration
Direct compatibility with E2.2S 1250 platforms reduces installation complexity, minimizing downtime during scheduled maintenance windows.
✓ Comprehensive Documentation Support
Includes technical specifications and installation guidelines aligned with IEC 60947 standards for professional electrical contractors.
Manufacturing Facilities with Continuous Operations
Production environments running 24/7 schedules require circuit protection systems that deliver predictable performance. This moving assembly supports preventive maintenance programs that replace wear-prone components before failure, avoiding unplanned shutdowns that disrupt manufacturing workflows and compromise delivery commitments.
Data Center Critical Power Infrastructure
Mission-critical IT facilities demand circuit breakers capable of isolating faults without cascading failures. The 1SDA072312R1 maintains the precise mechanical operation necessary for selective coordination schemes, protecting server loads while allowing upstream breakers to remain closed during downstream fault events.
Commercial Building Electrical Distribution
High-rise office complexes and retail centers with centralized switchgear benefit from OEM replacement parts that preserve original design margins. This component ensures main distribution breakers continue meeting short-circuit ratings specified in electrical drawings, maintaining compliance with building codes.
Renewable Energy Grid Integration Points
Solar farms and wind installations connecting to utility grids require robust switching equipment to handle bidirectional power flows and voltage fluctuations. This moving assembly supports the mechanical endurance needed for frequent switching operations in dynamic generation environments.
Industrial Retrofit and Upgrade Projects
Facilities extending the service life of existing Emax 2 installations can restore breaker performance through targeted component replacement rather than complete panel upgrades, optimizing capital expenditure while maintaining system reliability.
| Specification | Value |
|---|---|
| Manufacturer Part Number | 1SDA072312R1 |
| Compatible Breaker Series | SACE Emax 2 E2.2S 1250 |
| Trip Unit Configuration | Ekip Dip LSI 3-pole WMP |
| Component Weight | 53 kg |
| Country of Manufacture | Sweden |
| HS Classification Code | 8538900000 |
| Certification Standards | IEC 60947 Compliant |
Selection Criteria: Verify your existing circuit breaker nameplate data matches the E2.2S 1250 Ekip Dip LSI 3-pole WMP configuration before ordering. This moving assembly is frame-specific and cannot be adapted to other Emax 2 variants. Consult breaker documentation or contact technical support if you require assistance confirming compatibility with your installed equipment.
Maintenance Program Integration: This component supports condition-based maintenance strategies where moving assemblies are replaced at predetermined intervals based on switching cycle counts or thermal event logs captured by Ekip trip units. Facilities using ABB's Ability™ platform can correlate breaker operating data with component replacement schedules.
Spare Parts Inventory Optimization: For multi-site operations managing standardized Emax 2 installations, stocking this moving assembly reduces mean-time-to-repair (MTTR) by eliminating procurement delays during emergency maintenance scenarios.
Technical Training Support: ABB provides installation documentation and mechanical assembly diagrams that support in-house electrical teams performing component-level maintenance, reducing dependency on external service contractors.
Standard Lead Time: In-stock items ship within 1-2 business days via international courier services. Transit times vary by destination region—typically 5-7 days for Asia-Pacific, 7-10 days for Europe, and 10-14 days for Americas.
Custom Order Processing: Special configurations or bulk quantity orders may require 3-4 weeks for factory fulfillment. Contact our sales team for expedited processing options.
Warranty Coverage: 12-month comprehensive warranty covering manufacturing defects and material failures. Warranty activation begins upon delivery confirmation.
Technical Support: Access to certified electrical specialists for installation guidance, compatibility verification, and troubleshooting assistance via email and phone channels.
Documentation Package: Each shipment includes dimensional drawings, torque specifications, and installation procedures aligned with ABB service manuals.
How do I verify this moving assembly fits my existing circuit breaker installation?
Check the breaker nameplate for model designation "E2.2S 1250" and trip unit marking "Ekip Dip LSI 3p WMP." If your breaker displays these exact identifiers, the 1SDA072312R1 is the correct replacement component. For installations with modified configurations or field upgrades, contact our technical team with breaker serial number for verification.
What installation tools and expertise are required for component replacement?
Replacement requires qualified electrical personnel with experience servicing low-voltage power circuit breakers. Installation involves breaker de-energization, mechanical disassembly, precision alignment of moving contacts, and functional testing per IEC standards. Torque wrenches, insulation testers, and contact resistance measurement equipment are necessary.
Can this part restore interrupting capacity in breakers that have experienced fault events?
Moving assembly replacement addresses mechanical wear but does not restore arc chute erosion or contact surface degradation. Breakers that have interrupted fault currents approaching rated capacity should undergo comprehensive inspection including contact resistance testing and arc chamber evaluation before returning to service.
Does this component support remote monitoring or predictive maintenance systems?
The moving assembly itself contains no electronic components. However, when installed in breakers equipped with Ekip trip units featuring communication modules, the breaker's overall mechanical condition can be monitored through ABB's digital platforms that track operating cycles and thermal stress events.
What environmental conditions affect the service life of this moving assembly?
Operating environments with excessive humidity, corrosive atmospheres, or temperatures exceeding breaker ratings accelerate mechanical wear. Installations in coastal industrial facilities or chemical processing plants may require more frequent inspection intervals. Consult ABB environmental rating documentation for your specific application.
Are installation services available for facilities without in-house electrical maintenance teams?
We maintain partnerships with certified electrical contractors across major industrial regions. Contact our sales team with your facility location to receive referrals for qualified service providers experienced with Emax 2 breaker maintenance.
Ensure your critical power infrastructure maintains factory-certified performance standards. Contact our technical sales team to confirm compatibility with your specific installation, discuss volume pricing for multi-site maintenance programs, or request expedited delivery for emergency replacement scenarios.
Email: sale@ninermas.com
Phone: +0086 187 5021 5667
Business Hours: Monday-Friday, 9:00-18:00 CST
© 2026 NINERMAS COMPANY LIMITED. All rights reserved.
Original Source: https://ninermas.com
Contact: sale@ninermas.com | +0086 187 5021 5667