The ABB 1MRK002239-BBr01 is a high-reliability power supply module engineered specifically for ABB Relion series protection and control relays. Through advanced DC-DC conversion technology and comprehensive protection circuitry, it delivers stable, continuous power to critical substation automation equipment, ensuring uninterrupted operation in demanding industrial environments.
Designed for power utilities, industrial substations, renewable energy facilities, and critical infrastructure projects, this module addresses common challenges including voltage fluctuations, power source redundancy requirements, harsh electromagnetic environments, and the need for maintenance-free long-term operation in unmanned stations.
With standardized design and flexible configuration options, the 1MRK002239-BBr01 offers wide input voltage range, hot-swappable redundancy support, compact DIN-rail mounting, and full compliance with IEC standards—making it ideal for protection engineers, system integrators, EPC contractors, and facility operators. Contact our application engineers for customized power architecture recommendations and technical specifications.
This power supply module is engineered for applications demanding high availability, environmental resilience, and long-term stability, particularly in:
To facilitate engineering design and procurement, we provide key electrical and mechanical specifications. Custom configurations are available based on project-specific requirements.
| Parameter | Specification |
| Model Number | 1MRK002239-BBr01 |
| Input Voltage Range | 24-250V DC |
| Output Voltage | Typically 24V DC (relay-dependent) |
| Output Power | Consult datasheet for specific relay configuration |
| Efficiency | >85% |
| Operating Temperature | -40°C to +70°C |
| Protection Class | IP20 (when mounted in enclosure) |
| Mounting Method | 35mm DIN rail |
| Redundancy Support | Yes (parallel operation capable) |
| Compliance Standards | IEC 61850, IEC 60255 series |
| MTBF | >200,000 hours (at rated conditions) |
| Dimensions (H×W×D) | Refer to product datasheet |
Selection Recommendations: When specifying this module, consider the following factors: station DC bus voltage (48V, 110V, 220V systems), number of relays to be powered, redundancy requirements (single vs. dual supply), ambient temperature extremes, panel space constraints, and future expansion needs. For complex multi-relay configurations or custom voltage requirements, please provide your system architecture details—our engineers will recommend optimal power distribution schemes and calculate load budgets.
Lead Time: Standard catalog items typically ship within 3-5 business days from stock. Custom-configured or large-quantity orders may require 2-4 weeks—please confirm availability at time of inquiry.
Warranty: Backed by ABB's standard manufacturer warranty (minimum 24 months from delivery). Extended warranty and service agreements available upon request.
Technical Support: Comprehensive support including pre-sales application consulting, installation guidance, commissioning assistance, and post-sales troubleshooting. Remote technical support available; on-site service can be arranged for major projects (region-dependent).
Documentation Package: Each module ships with complete technical documentation including product datasheet, installation manual, wiring diagrams, dimensional drawings, and compliance certificates—ensuring smooth integration and regulatory compliance.
Q: How do I integrate the ABB 1MRK002239-BBr01 power supply module with existing Relion protection relays?
A: The module features standardized terminal connections compatible with all ABB Relion series relays. Simply mount on DIN rail, connect DC input from station battery, and wire output to relay auxiliary power terminals per the provided wiring diagram. Verify input voltage matches your station DC bus (24-250V range supported). For redundant configurations, parallel multiple modules with isolation diodes or ORing circuits.
Q: Can multiple power supply modules be used in parallel for redundancy?
A: Yes, the 1MRK002239-BBr01 supports N+1 redundancy through parallel operation. Each module operates independently with automatic load sharing. In the event of single-module failure, remaining units seamlessly maintain full power delivery without relay interruption. Consult application notes for proper redundancy wiring and load distribution calculations.
Q: What are the typical energy savings compared to traditional linear power supplies?
A: With >85% conversion efficiency, this switching-mode PSU reduces energy waste by approximately 30-40% versus older linear designs. In a typical substation with 20+ relays operating 24/7, annual energy savings can reach hundreds of kWh, lowering operational costs and reducing cooling requirements. Actual savings depend on input voltage, load profile, and ambient temperature.
Q: What environmental conditions can this power module withstand?
A: The module is rated for -40°C to +70°C ambient temperature, suitable for outdoor kiosks, unheated substations, and tropical climates. It meets IEC 60255 environmental standards including humidity, vibration, and EMI/EMC requirements. When installed in IP54+ rated enclosures, it operates reliably in dusty, corrosive, or high-altitude environments. Conformal coating options available for extreme conditions.
Q: Does the module support remote monitoring and SCADA integration?
A: The 1MRK002239-BBr01 provides local status indication via LED. For remote monitoring, it integrates with ABB Relion relays that support IEC 61850, Modbus, DNP3, and other SCADA protocols—allowing power supply status to be reported through the relay's communication interface. Dedicated power monitoring modules are available for standalone telemetry applications.
Q: What information do I need to provide for proper module selection?
A: Please specify: (1) Station DC bus voltage (e.g., 110V, 220V), (2) Number and model of relays to be powered, (3) Redundancy requirements (single/dual supply), (4) Ambient temperature range, (5) Available panel space and mounting orientation, (6) Any special environmental or certification requirements. Our engineers will validate compatibility and recommend optimal configuration.
For detailed selection assistance, custom power architecture design, or project-specific quotations, please provide the following information: Project name, application type (substation/industrial/renewable), relay models and quantities, station DC voltage, redundancy requirements, environmental conditions, and delivery timeline. Our application engineers will respond within 24 hours with tailored recommendations, technical drawings, and competitive pricing.
© 2026 NINERMAS COMPANY LIMITED. All rights reserved.
Original Source: https://ninermas.com
Contact: sale@ninermas.com | +0086 187 5021 5667