Original Industrial Spare Part

Schneider ATV340D15N4 Service-Ready Spare Part for Industrial Maintenance

Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.

SKU: ATV340D15N4 PLC & Industrial Automation Modules Schneider Electric

RFQ Ready

Pricing by RFQ

How Buyers Usually Use This Page

  • Confirm the exact part number and platform family before sending the quote request.
  • Use direct email when quantity, condition, and destination are already defined internally.
  • Switch to the broader brand or category archive when you need alternates nearby.

Series Navigation

Move through the most common platform families behind this part.

Schneider ATV340D15N4 Service-Ready Spare Part for Industrial Maintenance

The Schneider Electric ATV340D15N4 is a 15 kW (20 HP) three-phase 380–480 V AC variable speed drive from the Altivar 340 series, engineered for demanding industrial environments including conveyor systems, pumps, fans, compressors, and general-purpose machine automation. As a service-ready spare part, the ATV340D15N4 is stocked to support rapid field replacement, minimise unplanned downtime, and extend the operational life of legacy and current-generation control systems.

Maintenance engineers and procurement teams managing multi-drive production lines recognise that a single failed VFD can halt an entire process. Holding a verified, pre-tested ATV340D15N4 in the on-site spare parts cabinet eliminates the lead-time risk associated with emergency procurement and ensures that motor control is restored within a single maintenance shift.

Spare Maintenance Table

Parameter Specification
SKU / Part Number ATV340D15N4
Brand / Series Schneider Electric / Altivar 340
Product Type Variable Speed Drive (VFD / AC Drive)
Rated Power Output 15 kW (20 HP)
Supply Voltage 380–480 V AC, 3-Phase, 50/60 Hz
Output Current (Nominal) 32 A
Protection Rating IP21 (panel-mount); IP55 with optional kit
Control Modes V/f, Sensorless Flux Vector, Closed-Loop Vector
Communication Protocols Modbus RTU (built-in); CANopen, EtherNet/IP, Profibus DP (optional cards)
Ambient Operating Temperature -10 °C to +50 °C (derate above 40 °C)
Altitude Up to 1000 m without derating
Braking DC injection; dynamic braking resistor terminal available
Compatibility Direct replacement for ATV340D15N4; compatible with Altivar 340 series wiring and parameter sets
Installation DIN rail or panel mount; standard ATV340 footprint
Warranty 12 Months — covers manufacturing defects; pre-shipment functional test included
Origin France (Schneider Electric)
Condition Original / New

Maintenance Planning for Continuous Operation

When replacing an ATV340D15N4 in the field, a structured inspection of the surrounding electrical circuit is essential to prevent repeat failures and confirm system integrity before restart. Maintenance engineers should treat the VFD replacement as an opportunity to audit the entire motor control loop.

Begin with the input power supply: verify that the upstream circuit breaker or GV2 or GV3 series motor circuit breaker is correctly rated for the drive’s input current and has not suffered contact erosion. Check the line reactor or EMC input filter — a degraded filter can allow voltage spikes that shorten drive life. Inspect the 24 V DC control power supply (such as an ABL8 or Phaseo series SMPS) that feeds the drive’s logic board and any connected safety relays.

On the output side, measure motor insulation resistance before reconnecting the ATV340D15N4 to the motor terminals. A deteriorated motor winding is a common root cause of repeated drive failures. Verify that the motor cable shielding is properly grounded at the drive end to suppress EMI. If a dynamic braking resistor is installed, inspect its thermal condition and connection integrity.

Review the I/O wiring: confirm that analog input signals (speed reference, PID feedback) and digital inputs (run/stop, fault reset, preset speeds) are correctly terminated. Check the condition of the terminal block or spring-clamp I/O connectors for corrosion or loose wires. If the drive communicates over Modbus RTU or an optional VW3A3616 EtherNet/IP communication card, verify network termination resistors and cable continuity.

Inspect the control cabinet ventilation: blocked filters or failed cabinet fans raise ambient temperature and accelerate drive aging. If the cabinet houses additional Altivar drives — such as an ATV340U40N4 (4 kW) or ATV340D22N4 (22 kW) — confirm that thermal derating is not occurring across the group. Check any TeSys D or TeSys K contactors used for bypass or star-delta switching, as worn contacts can cause voltage transients on drive restart.

For sites running Modicon M340 or M580 PLC systems, verify that the drive’s parameter file (stored on the PLC or a VW3A3601 keypad with memory card) is current and matches the replacement unit’s firmware version. This eliminates manual re-parameterisation and reduces commissioning time to under 30 minutes.

Site Replacement Workflow

Step 1 — Isolation and lockout: Isolate the drive from the supply using the upstream isolator or circuit breaker. Apply LOTO (Lockout/Tagout) and wait a minimum of 15 minutes for DC bus capacitors to discharge before opening the enclosure.

Step 2 — Parameter backup: If the existing drive is still partially functional, use the VW3A3601 remote keypad or SoMove PC software to export the parameter set. This backup is critical for rapid recommissioning of the ATV340D15N4 replacement unit.

Step 3 — Physical swap: Disconnect power cables (L1/L2/L3), motor cables (U/V/W), control wiring, and the communication card if fitted. Remove the failed unit. Mount the replacement ATV340D15N4 using the same DIN rail or panel fixings — the Altivar 340 series maintains a consistent mechanical footprint across the power range, simplifying like-for-like substitution.

Step 4 — Parameter restore and pre-run checks: Load the saved parameter file. Confirm motor nameplate data (rated voltage, current, frequency, speed) matches the drive configuration. Set the correct acceleration/deceleration ramps for the application. Verify all digital and analog I/O signals with the PLC in manual mode before enabling auto-run.

Step 5 — Functional test: Run the motor at low speed (5–10 Hz) and confirm direction, current draw, and absence of fault codes. Gradually ramp to full operating speed and monitor output current against the motor’s rated value. Log the commissioning date and drive serial number in the site maintenance record.

This workflow is applicable to conveyor drives, pump stations, HVAC fan drives, and any other ATV340-controlled application. The consistent parameter architecture across the Altivar 340 range means that engineers familiar with one model can commission any variant — including the ATV340D15N4E EMC-enhanced variant — without additional training.

Spare Parts Support FAQ

Q1: Is the ATV340D15N4 a direct replacement for older Altivar 31 or Altivar 312 drives?
The ATV340D15N4 is not a pin-compatible drop-in for ATV31 or ATV312 units due to differences in terminal layout and parameter structure. However, it is functionally equivalent and can replace those drives with minor wiring adaptation and re-parameterisation. Schneider Electric’s migration guides provide terminal mapping tables to simplify the transition and reduce engineering time on site.

Q2: What pre-shipment testing is performed on this spare part?
Each ATV340D15N4 unit is subject to a functional power-on test prior to dispatch. The test confirms correct display operation, input voltage recognition, and output switching. Units that do not pass the test are not shipped. A 12-month warranty covering manufacturing defects is included with every unit, providing procurement engineers with a documented quality assurance baseline for spare parts inventory records.

Q3: How should the ATV340D15N4 be stored as a long-term spare?
Store the unit in its original packaging in a dry, temperature-controlled environment (5 °C to 40 °C, relative humidity below 95% non-condensing). For storage periods exceeding 12 months, Schneider Electric recommends a periodic power-up cycle (apply rated voltage for 1 hour annually) to reform the DC bus electrolytic capacitors and maintain drive readiness. Label the spare with the storage date and planned commissioning window.

Q4: Can long-term supply of the ATV340D15N4 be guaranteed for legacy system support?
Yes. We maintain a dedicated stock of Altivar 340 series drives to support customers operating legacy automation systems beyond the standard product lifecycle. Procurement engineers managing multi-year maintenance contracts or OEM service agreements are encouraged to contact us to discuss volume reservation, scheduled delivery, and consignment stock arrangements that align with planned maintenance windows and annual shutdown schedules.

Product Series

Altivar

Country of Origin

FR

Catalog Continuation

Nearby part numbers around ATV340D1.

Use this lane when the buyer is comparing adjacent model numbers, revision-near items, or closely related spare variants within the same brand family.

Open this lane

Catalog Continuation

More Schneider Electric modules in the catalog.

Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.

Open this lane

Catalog Continuation

Alternative parts within PLC & Industrial Automation Modules.

Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.

Open this lane

Industrial RFQ Support

Need a fast quote for a specific part number or system family?

Send your inquiry with brand, series, quantity, condition, and destination details. We will follow up on availability, lead time, and shipping options.

CallPhone MailEmail WAChat TopBack