Original Industrial Spare Part

Allen-Bradley 1746-NO4V Analog Output Module (SLC 500) — New & Original

Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.

SKU: 1746-NO4V PLC & Industrial Automation Modules Allen-Bradley (Rockwell)

RFQ Ready

Request pricing & availability

How Buyers Usually Use This Page

  • Confirm the exact part number and platform family before sending the quote request.
  • Use direct email when quantity, condition, and destination are already defined internally.
  • Switch to the broader brand or category archive when you need alternates nearby.

Series Navigation

Move through the most common platform families behind this part.

Allen-Bradley 1746-NO4V | Reliable Automation Component for SLC 500 Systems

Field Application & Operational Analysis

From a Site Reliability Engineer’s perspective, the Allen-Bradley 1746-NO4V stands as a mission-critical automation component within SLC 500 control architectures. Its 4-channel isolated voltage output design directly contributes to system availability by enabling precise, independent signal conditioning across multiple field devices simultaneously — reducing single-point failure risk in process optimization loops. The 1746-NO4V is engineered to sustain operational excellence in demanding environments where signal integrity is non-negotiable.

Deployed across petrochemical, water treatment, and discrete manufacturing facilities, this I/O module demonstrates exceptional durability under thermal cycling and electrical noise conditions. Installation requires careful attention to backplane slot compatibility within the 1746 modular chassis family, proper shielded cable routing to suppress EMI, and verification of power supply headroom — 150mA at 5V DC plus 50mA at 24V DC — prior to commissioning. Grounding discipline is paramount for maintaining 16-bit output fidelity.

For maintenance planners and reliability engineers, stocking the 1746-NO4V as a critical spare is a fundamental risk mitigation strategy. As SLC 500 platforms transition toward end-of-life status, securing verified original inventory ensures uninterrupted production continuity and eliminates costly emergency procurement delays during unplanned outages.

Key Operational Features

4 Isolated Analog Voltage Output Channels — Independent channel isolation at 500V AC continuous for high availability in multi-loop control systems
16-Bit Converter Resolution — Delivers superior signal precision for demanding process optimization applications
Configurable Output Range — Supports 0-10V DC or ±10V DC per system requirement, enabling seamless integration into diverse field device networks
Hot-Swap Capability — Minimizes planned maintenance windows and supports redundancy strategies without full system shutdown
Factory-Calibrated Outputs — Ensures measurement accuracy from first power-on, reducing commissioning time
LED Diagnostic Indicators — Provides real-time status visibility for rapid fault isolation during field troubleshooting
RSLogix 500 Compatible — Native system integration with Allen-Bradley programming environment, zero additional configuration overhead

Maintenance & Performance Benchmarks

The 1746-NO4V is architected to adapt across industrial network scales — from compact standalone SLC 5/01 systems to large distributed I/O configurations utilizing 1746-A13 chassis with multiple I/O racks. Its 20ms per-channel update rate sustains real-time responsiveness in high-throughput automation environments.

Preventive maintenance protocols should include periodic verification of output voltage accuracy against calibrated references, inspection of terminal block torque values (recommended 0.5-0.6 N·m), and confirmation of backplane connector seating integrity. Mean Time Between Failures (MTBF) data supports extended service intervals when environmental conditions remain within rated operating parameters (0°C to 60°C).

For multi-rack architectures, engineers should validate backplane power budgets cumulatively across all installed modules. The module’s low power profile supports dense I/O configurations without requiring supplemental power supply upgrades in most standard chassis deployments.

Comprehensive Data Sheet

Attribute Technical Data
Full Model Number 1746-NO4V
Manufacturer Allen-Bradley (Rockwell Automation)
Product Series SLC 500
Module Type Analog Output Module
Output Channels 4 isolated analog voltage outputs
Converter Resolution 16-bit
Output Voltage Range 0-10V DC or ±10V DC (software configurable)
Update Rate 20ms per channel (typical)
Channel-to-Backplane Isolation 500V AC continuous
Power Consumption 150mA @ 5V DC; 50mA @ 24V DC
Operating Temperature 0°C to 60°C (32°F to 140°F)
Chassis Compatibility 1746-A4, A7, A10, A13 modular chassis
Programming Software RSLogix 500
Certifications UL Listed, CE Marked, RoHS Compliant
Wiring Interface Removable terminal blocks
Condition New & Original Factory Stock
Warranty 12 Months

Professional Logistics & Sourcing Excellence

Every 1746-NO4V unit dispatched from our inventory is supplied in Original Factory Packaging, preserving full traceability documentation, factory calibration records, and OEM labeling integrity. For time-critical production recovery scenarios, same-day dispatch is available for in-stock units confirmed before daily cut-off — supporting worldwide express logistics to minimize plant downtime exposure.

As Allen-Bradley SLC 500 components approach end-of-life (EOL) and legacy status, our global sourcing network maintains verified stock of authentic modules to serve facilities committed to long-term SLC 500 platform operation. We specialize in supplying EOL and legacy automation components with full authenticity verification, ensuring your procurement team receives only genuine Rockwell Automation product — never counterfeit or refurbished substitutes.

Engineering Support & FAQ

Q: What are the installation steps for the 1746-NO4V in an existing SLC 500 system?
A: Power down the chassis, insert the module into any available 1746 I/O slot, secure the locking tab, reconnect power, then configure the module in RSLogix 500 by assigning the correct I/O address and selecting the desired output voltage range (0-10V or ±10V). Verify output signals with a calibrated multimeter before going live.

Q: Which RSLogix 500 firmware versions are compatible with the 1746-NO4V?
A: The 1746-NO4V is compatible with all RSLogix 500 software versions from v7.0 onward. As a hardware-based analog output module, it does not carry its own firmware — compatibility is determined solely by the SLC 500 processor series (SLC 5/01 through SLC 5/05) and chassis revision.

Q: Can individual channels be configured for different voltage ranges?
A: No. All four channels on the 1746-NO4V share a common output range configuration. The range (0-10V DC or ±10V DC) is set globally via RSLogix 500 software and applies uniformly across all channels.

Q: How is the warranty claim process handled?
A: Our 12-month warranty covers manufacturing defects and workmanship failures under normal operating conditions. To initiate a claim, contact our technical support team with the module serial number, purchase documentation, and a description of the observed fault. Replacement or repair is processed within standard lead times, with expedited options available for mission-critical applications.

Q: What cable specifications are recommended for output wiring?
A: Use shielded twisted-pair (STP) cable with a minimum conductor gauge of 22 AWG. Keep output cable runs under 300 meters (1,000 feet) and ensure shield grounding at one end only to prevent ground loop interference — a critical factor for maintaining 16-bit output accuracy in electrically noisy industrial environments.

Q: Is the 1746-NO4V suitable for use in safety-rated control systems?
A: The 1746-NO4V is a standard automation component and is not SIL-rated for use in IEC 61508 functional safety applications. For safety system integration, consult Rockwell Automation’s GuardLogix or Safety PLC product lines. The 1746-NO4V is optimized for process optimization and operational excellence in standard industrial control architectures.

© 2026 NINERMAS COMPANY LIMITED. All rights reserved. Original Source: https://ninermas.com | Contact: sale@ninermas.com | +0086 187 5021 5667

Product Series

Other Legacy / Discontinued Modules

Country of Origin

US

Reviews

There are no reviews yet.

Be the first to review “Allen-Bradley 1746-NO4V Analog Output Module (SLC 500) — New & Original”

Your email address will not be published. Required fields are marked

Catalog Continuation

Likely SLC 500 platform matches.

These parts are closer to the same platform family signaled by the current SKU and title, so buyers can validate continuity before sending a final RFQ.

Open this lane

Catalog Continuation

More Allen-Bradley (Rockwell) modules in the catalog.

Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.

Open this lane

Catalog Continuation

Alternative parts within PLC & Industrial Automation Modules.

Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.

Open this lane

Industrial RFQ Support

Need a fast quote for a specific part number or system family?

Send your inquiry with brand, series, quantity, condition, and destination details. We will follow up on availability, lead time, and shipping options.

CallPhone MailEmail WAChat TopBack