Original Industrial Spare Part
GE IC695CMM004 Service-Ready Spare Part for Industrial Maintenance
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKUIC695CMM004
- CategoryPLC & Industrial Automation Modules
- BrandGE
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: GE IC695CMM004 Service-Ready Spare Part for Industrial Maintenance with SKU IC695CMM004.
GE IC695CMM004 Service-Ready Spare Part for Industrial Maintenance
The GE IC695CMM004 is an original serial communications module designed for the GE PACSystems RX3i platform — one of the most widely deployed PLC architectures in process control, discrete manufacturing, and utility automation. Sourced and stocked by NINERMAS as a verified service-ready spare, the IC695CMM004 supports both RS-232 and RS-485 serial protocols, enabling reliable point-to-point and multi-drop communication between the RX3i backplane and field devices such as drives, meters, barcode readers, and legacy SCADA terminals.
For maintenance engineers managing aging control systems, the IC695CMM004 represents a critical link in the communication chain. When this module fails — whether due to surge damage, connector wear, or firmware incompatibility after a CPU upgrade — the result is immediate loss of serial device visibility, which can cascade into unplanned downtime across an entire production line. Having a pre-tested, shelf-ready replacement on hand is the single most effective way to compress mean time to repair (MTTR) and restore normal operation within a single shift.
NINERMAS maintains stock of the IC695CMM004 with full pre-shipment functional testing, original packaging where available, and a 12-month warranty covering manufacturing defects and operational failure under normal industrial use conditions. Each unit is inspected for physical integrity, port condition, and firmware revision compatibility before dispatch.
Spare Maintenance Table
| Parameter | Specification |
|---|---|
| Part Number | IC695CMM004 |
| Brand / Manufacturer | GE (GE Fanuc / Emerson Automation) |
| Series / Platform | PACSystems RX3i |
| Module Type | Serial Communications Module |
| Supported Protocols | RS-232, RS-485 (2-wire and 4-wire) |
| Number of Ports | 4 isolated serial ports |
| Backplane Interface | RX3i Universal Backplane (IC694 / IC695 series) |
| Operating Voltage | Supplied via backplane (3.3 V / 5 V logic) |
| Operating Temperature | 0°C to 60°C (32°F to 140°F) |
| Relative Humidity | 5% to 95% non-condensing |
| Mounting | RX3i backplane slot (any universal slot) |
| Compatibility | IC695CPU310, IC695CPU315, IC695CPU320, IC695CPU330, IC695CRU320 |
| Origin | United States |
| Condition | Original / Refurbished-Tested |
| Warranty | 12 Months — Covers manufacturing defects and operational failure |
| Pre-Shipment Testing | Yes — Port continuity, firmware check, physical inspection |
| Lead Time | In stock — ships within 1–3 business days |
Maintenance Planning for Continuous Operation
When a maintenance or procurement engineer schedules replacement of the IC695CMM004, the scope of inspection should extend well beyond the module itself. Serial communication failures in RX3i systems are frequently symptomatic of broader electrical stress in the control cabinet. A disciplined replacement workflow should include verification of the following associated components:
Begin with the IC695PSA040 or IC695PSD040 power supply module, which feeds the backplane. Voltage ripple or marginal output on the 5 V rail is a common root cause of intermittent serial communication errors that are misdiagnosed as module failure. Confirm output voltage under load before installing the replacement IC695CMM004.
Inspect the IC695CHS016 or IC695CHS012 backplane for slot connector damage, corrosion, or bent pins. A damaged backplane slot can destroy a replacement module within hours of installation. If the backplane shows signs of arcing or discoloration near the failed slot, relocate the IC695CMM004 to an alternate slot and update the hardware configuration in the programming software accordingly.
Check all RS-232 and RS-485 field wiring terminating at the module’s port connectors. Shielding continuity, ground loops, and incorrect termination resistors on RS-485 multi-drop networks are leading causes of communication instability. Replace any degraded terminal blocks or field connectors at the same time as the module swap.
If the RX3i rack also houses an IC695ETM001 Ethernet communications module or an IC695PBM300 PROFIBUS master module, verify that these modules are operating normally after the IC695CMM004 replacement, as backplane resets during hot-swap or power cycling can occasionally affect neighboring module states.
For systems using IC695ALG608 or IC695ALG616 analog I/O modules in the same rack, confirm that analog signal integrity is unaffected after the maintenance event. Grounding disturbances introduced during module replacement can shift analog baselines, particularly in 4–20 mA current loop circuits.
Where the IC695CMM004 is used to interface with third-party HMI panels via RS-232 (such as Weintek, Proface, or Siemens TP series), re-validate the communication parameters — baud rate, parity, stop bits, and handshaking — after module replacement, as firmware revision differences between IC695CMM004 units can occasionally require parameter re-confirmation.
Finally, review the IC695RMX128 or IC695RMX228 redundancy modules if the system operates in a hot-standby configuration. Serial module replacement in redundant RX3i systems requires careful sequencing to avoid triggering an unintended switchover. Always consult the GE PACSystems RX3i Hardware Reference Manual (GFK-2314) before proceeding in redundant architectures.
NINERMAS recommends maintaining a minimum of one IC695CMM004 per active RX3i rack in your site spare parts inventory, alongside matched spares for the power supply, CPU, and Ethernet modules, to ensure full rack recovery capability without waiting on procurement lead times.
Site Replacement Workflow
Step 1 — Pre-replacement documentation: Export the current hardware configuration from GE Proficy Machine Edition or the applicable programming environment. Record the slot assignment, port configuration (baud rate, protocol, parity), and any custom communication parameters for each of the four ports. This documentation is essential for rapid recommissioning after the swap.
Step 2 — Safe de-energization: Follow site lockout/tagout (LOTO) procedures. Power down the RX3i rack via the main disconnect. Do not attempt hot-swap of the IC695CMM004 unless your system configuration and GE documentation explicitly support it for this module revision.
Step 3 — Module extraction and inspection: Remove the failed IC695CMM004 and inspect the backplane slot connector. Clean with dry compressed air if contamination is present. Compare the firmware label on the failed unit with the replacement to identify any revision differences that may require configuration updates.
Step 4 — Replacement installation: Seat the new IC695CMM004 firmly into the designated backplane slot. Reconnect all field wiring to the port connectors, verifying correct pin assignments against the original documentation. Torque terminal screws to specification to prevent intermittent contact.
Step 5 — Power-up and validation: Restore power and observe the module status LEDs. A solid green OK LED confirms successful backplane communication. Download the hardware configuration if required by the firmware revision. Verify serial communication to each connected field device by monitoring the port activity LEDs and confirming data exchange in the PLC diagnostic tables.
Step 6 — Post-replacement documentation: Update the site maintenance log with the replacement date, module serial number, firmware revision, and technician name. Archive the updated hardware configuration file. Schedule the next inspection interval per your preventive maintenance plan.
Spare Parts Support FAQ
Q1: Is the IC695CMM004 supplied by NINERMAS compatible with all RX3i CPU revisions?
The IC695CMM004 is compatible with all standard RX3i universal backplane configurations, including systems running IC695CPU310, IC695CPU315, IC695CPU320, and IC695CPU330 processors. For systems using older IC694-series CPUs in mixed racks, compatibility should be verified against the GE hardware compatibility matrix. NINERMAS technical support can assist with compatibility confirmation prior to order placement.
Q2: What pre-shipment testing does NINERMAS perform on the IC695CMM004?
Every IC695CMM004 unit undergoes physical inspection for connector integrity and housing condition, firmware revision identification, and port-level continuity verification before dispatch. Units that do not pass inspection are not shipped. A test report summary is available upon request for critical infrastructure procurement.
Q3: What does the 12-month warranty cover, and how is a warranty claim processed?
The 12-month warranty covers manufacturing defects and operational failure under normal industrial operating conditions. It does not cover damage resulting from incorrect installation, overvoltage events, or physical mishandling. To initiate a warranty claim, contact NINERMAS at sale@ninermas.com with the order reference, a description of the failure mode, and photographic evidence of the defect. Replacement or repair will be arranged within 5 business days of claim confirmation.
Q4: Can NINERMAS support long-term or blanket purchase orders for the IC695CMM004?
Yes. NINERMAS supports long-term supply agreements for the IC695CMM004 and related RX3i spare parts. For facilities managing multiple RX3i installations or operating under annual maintenance contracts, blanket purchase orders with scheduled delivery releases are available. Contact our sales team to discuss volume pricing, reserved stock arrangements, and multi-site delivery coordination.
| Product Series | Fanuc |
|---|---|
| Country of Origin | US |
Catalog Continuation
Nearby part numbers around IC695CMM.
Use this lane when the buyer is comparing adjacent model numbers, revision-near items, or closely related spare variants within the same brand family.
Catalog Continuation
More GE modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
Catalog Continuation
Alternative parts within PLC & Industrial Automation Modules.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
SKU: VT-VSPA1-1-12
REXROTH VT-VSPA1-1-12 Retrofit-Compatible Analog Amplifier
SKU: 00-170-819 00-170-819 00-187-547 00-187-547 00-176-109 RV-410F-236
KUKA RV-410F-236 Retrofit-Compatible Gearbox for Legacy Systems
SKU: 3HAC044168-001