Original Industrial Spare Part
GE IC695ETM001-LDAB Service-Ready Spare Part for Industrial Maintenance
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKUIC695ETM001-LDAB IC695ETM001
- CategoryPLC & Industrial Automation Modules
- BrandGE
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: GE IC695ETM001-LDAB Service-Ready Spare Part for Industrial Maintenance with SKU IC695ETM001-LDAB IC695ETM001.
GE IC695ETM001-LDAB Service-Ready Spare Part for Industrial Maintenance
The GE IC695ETM001-LDAB is an original Ethernet communications module designed for the GE PACSystems RX3i platform — one of the most widely deployed PLC architectures in process automation, discrete manufacturing, and critical infrastructure. For maintenance engineers managing aging control systems, sourcing a verified, service-ready IC695ETM001-LDAB is often the difference between a two-hour recovery and a multi-day production shutdown.
This module provides 10/100 Mbps Ethernet connectivity for the RX3i backplane, supporting SRTP, Modbus TCP, and EGD (Ethernet Global Data) protocols. It is a direct replacement for failed or end-of-life units and is fully compatible with existing RX3i rack configurations without firmware re-engineering. Every unit shipped by NINERMAS undergoes pre-shipment functional verification to confirm communication integrity, backplane interface health, and LED status response before dispatch.
Spare Maintenance Table
| Parameter | Specification |
|---|---|
| Part Number | IC695ETM001-LDAB |
| Series | GE PACSystems RX3i |
| Module Type | Ethernet Communications Module |
| Network Speed | 10/100 Mbps Auto-Negotiation |
| Supported Protocols | SRTP, Modbus TCP, EGD, HTTP |
| Backplane Compatibility | IC695CHS012, IC695CHS016, IC695CHS007 |
| Power Consumption | 3.3 W (typical) |
| Operating Temperature | 0°C to 60°C |
| Humidity | 5% to 95% non-condensing |
| Mounting | RX3i Universal Backplane Slot |
| Firmware | Compatible with Proficy Machine Edition 8.x and above |
| Origin | United States |
| Warranty | 12 Months — NINERMAS Quality Guarantee |
| Condition | Original / Service-Ready |
| Pre-Shipment Test | Communication, backplane interface, LED diagnostics |
Maintenance Planning for Continuous Operation
When a maintenance engineer identifies a failed IC695ETM001-LDAB during a control cabinet inspection or fault isolation routine, the replacement workflow rarely ends with the Ethernet module alone. The RX3i control architecture is deeply integrated, and a thorough site assessment should accompany any module swap to prevent repeat failures and ensure full system restoration.
Begin by inspecting the IC695PSA140 or IC695PSD040 power supply module — an unstable DC bus is one of the leading causes of premature Ethernet module failure in RX3i systems. Verify output voltage rails are within tolerance before installing the replacement IC695ETM001-LDAB. Next, check the IC695CPU320 or IC695CPE330 CPU module for active fault logs; communication faults logged against the ETM001 slot may indicate a deeper backplane or firmware issue rather than a hardware defect in the module itself.
Inspect all RJ45 patch cables and managed switch ports connected to the ETM001. Degraded cabling or misconfigured switch VLANs are frequently overlooked during emergency replacements and can cause the new module to exhibit the same symptoms as the failed unit. If the system uses IC695ETM001 in a redundant Ethernet configuration, verify that the secondary module’s IP addressing and EGD exchange tables are synchronized after the swap.
For systems with IC695ALG600 or IC695ALG616 analog I/O modules in the same rack, confirm that the backplane communication scan cycle has not been disrupted by the module replacement. Similarly, if the cabinet includes IC695CMM002 serial communication modules for legacy device integration, verify that their configuration remains intact in the CPU after the ETM001 is restored.
Procurement engineers building annual spare parts lists for RX3i-based lines should also consider stocking the IC695MDL654 discrete output module and IC695MDL664 discrete input module alongside the ETM001, as these are high-cycle components in the same control cabinet. For facilities running Proficy HMI/SCADA iFIX or Cimplicity supervisory systems, confirm that the SRTP driver configuration on the SCADA server reflects the replacement module’s IP address to restore full data acquisition without manual intervention.
Long-term maintenance strategies for aging RX3i systems should include periodic inspection of IC695CHS012 backplane connectors for oxidation or mechanical wear, as poor backplane contact is a silent contributor to intermittent Ethernet module faults that are difficult to reproduce during bench testing.
Site Replacement Workflow
Step 1 — Pre-Replacement Verification: Document the existing IC695ETM001-LDAB configuration using Proficy Machine Edition. Export the hardware configuration file and note the module’s IP address, subnet mask, gateway, and EGD exchange table assignments. This ensures zero-configuration-loss restoration after the swap.
Step 2 — Power Down Sequence: Follow the site’s lockout/tagout (LOTO) procedure. De-energize the RX3i rack via the IC695PSA140 power supply. Allow capacitors to discharge for a minimum of 30 seconds before handling backplane modules.
Step 3 — Module Removal: Release the IC695ETM001-LDAB from the backplane slot using the module ejector tabs. Inspect the backplane connector pins for damage or contamination before inserting the replacement unit.
Step 4 — Replacement Installation: Seat the new IC695ETM001-LDAB firmly into the same backplane slot. Reconnect the RJ45 Ethernet cable. Restore power and observe the module’s LED indicators — OK (green), LAN (amber/green activity), and FAULT (should remain off).
Step 5 — Configuration Restore: Using Proficy Machine Edition, download the previously exported hardware configuration to the CPU. Verify that the ETM001 slot is recognized and that IP settings are correctly applied. Ping the module from the engineering workstation to confirm network connectivity.
Step 6 — System Validation: Confirm SCADA/HMI data acquisition has resumed. Check EGD exchange health in the CPU diagnostics. Log the replacement in the site’s maintenance management system (CMMS) with the new module’s serial number and installation date.
This workflow minimizes mean time to repair (MTTR) and ensures the replacement IC695ETM001-LDAB is fully operational within a single maintenance window, reducing unplanned downtime risk for production lines dependent on RX3i-based control.
Spare Parts Support FAQ
Q1: Is the IC695ETM001-LDAB compatible with all RX3i backplane configurations?
The IC695ETM001-LDAB is compatible with standard RX3i universal backplanes including the IC695CHS012 (12-slot), IC695CHS016 (16-slot), and IC695CHS007 (7-slot). It occupies a single universal slot and does not require a dedicated slot position. Compatibility with Proficy Machine Edition 8.x and above is confirmed; older firmware versions may require a CPU update prior to module installation.
Q2: What is included in NINERMAS’s 12-month warranty for this spare part?
Every IC695ETM001-LDAB shipped by NINERMAS carries a 12-month warranty covering manufacturing defects and functional failures under normal operating conditions. Pre-shipment testing includes backplane interface verification, Ethernet communication handshake testing, and LED diagnostic confirmation. In the event of a warranty claim, NINERMAS provides a replacement unit or full refund within the warranty period.
Q3: How does NINERMAS ensure long-term supply availability for discontinued GE PACSystems modules?
NINERMAS maintains a dedicated inventory of legacy GE PACSystems RX3i components, including the IC695ETM001-LDAB, to support facilities operating extended-life control systems. Our procurement team sources original units through authorized distribution and certified secondary market channels. Customers with multi-site or multi-unit requirements are encouraged to contact our sales team to discuss volume pricing and reserved stock agreements.
Q4: Can the IC695ETM001-LDAB be tested before shipment upon request?
Yes. All units undergo standard pre-shipment functional verification as part of NINERMAS’s quality control process. Customers requiring application-specific testing or burn-in procedures can request enhanced pre-shipment inspection. Test reports are available upon request and can be included with the shipment documentation for site acceptance records.
| Product Series | PACSystems |
|---|---|
| Country of Origin | US |
Catalog Continuation
Nearby part numbers around IC695ETM.
Use this lane when the buyer is comparing adjacent model numbers, revision-near items, or closely related spare variants within the same brand family.
Catalog Continuation
More GE modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
Catalog Continuation
Alternative parts within PLC & Industrial Automation Modules.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
SKU: 4-AXIS BXI4/2-01-B
BERKELEY BXI4/2-01-B Retrofit-Compatible Motion Controller
SKU: METEOR/RGB PCI 571-03
Matrox METEOR/RGB PCI 571-03 Service-Ready Spare Part