Original Industrial Spare Part
Schneider Electric LMC20A1307 Service-Ready Spare Part
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKULMC20A1307
- CategoryPLC & Industrial Automation Modules
- BrandSchneider Electric
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: Schneider Electric LMC20A1307 Service-Ready Spare Part with SKU LMC20A1307.
Schneider Electric LMC20A1307 Service-Ready Spare Part for Industrial Maintenance
The Schneider Electric LMC20A1307 is a Lexium Motion Controller module designed for precision motion control in industrial automation environments. As a service-ready spare part, the LMC20A1307 is a critical component for maintenance engineers managing multi-axis servo systems, packaging lines, material handling conveyors, and legacy motion control cabinets. Unplanned downtime caused by a failed motion controller can halt an entire production line within minutes. Stocking the LMC20A1307 as a verified spare ensures rapid restoration of motion sequences without waiting on extended lead times from OEM channels.
This unit is sourced as an original Schneider Electric component, pre-shipment tested, and supplied with a 12-month warranty covering manufacturing defects and functional integrity. Whether you are executing a planned annual overhaul, responding to an emergency fault, or building a strategic spare parts inventory for a Lexium-based control system, the LMC20A1307 provides a direct, compatible replacement path with no firmware reconfiguration required in most standard Lexium Motion configurations.
Spare Maintenance Table
| Part Number | LMC20A1307 |
| Brand | Schneider Electric |
| Series | Lexium Motion Controller (LMC20) |
| Product Type | Motion Controller Module |
| Application | Multi-axis servo motion control, packaging, conveyor, press, and assembly automation |
| Communication Interface | CANopen, Sercos, EtherCAT (series-dependent configuration) |
| Power Supply Compatibility | 24 VDC control supply; compatible with Lexium power supply modules |
| I/O Integration | Digital I/O via backplane or expansion modules; compatible with Modicon I/O bus |
| Operating Temperature | 0°C to +55°C (standard industrial panel environment) |
| Mounting | DIN rail or panel mount; standard Lexium rack form factor |
| Firmware | Compatible with Lexium CT / SoMachine Motion programming environment |
| Origin | France (Schneider Electric manufacturing) |
| Condition | Original, new or tested-serviceable spare |
| Pre-Shipment Test | Functional power-on and communication verification performed |
| Warranty | 12 Months — covers manufacturing defects and functional performance |
| Lead Time | Typically 3–7 business days; expedited options available |
Maintenance Planning for Continuous Operation
When a Lexium Motion Controller such as the LMC20A1307 is identified as a fault point during a control cabinet inspection or post-trip analysis, experienced maintenance engineers know that the motion controller rarely fails in isolation. A thorough site replacement plan should include inspection and, where appropriate, simultaneous replacement of adjacent components that share the same electrical environment and operational stress cycle.
Begin with the 24 VDC control power supply feeding the LMC20 rack — units such as the Schneider Electric ABL8REM24030 or equivalent Phaseo power supply modules should be load-tested and verified for output ripple before the new controller is commissioned. A degraded power supply is a common root cause of intermittent motion controller faults and can damage a replacement unit if left unaddressed.
Next, inspect the Lexium servo drive modules connected to the LMC20A1307 — typically LXM32 or LXM05 series drives. Check DC bus voltage, brake resistor condition, and encoder feedback cable integrity. Faulty encoder cables or loose D-sub connectors on the SinCos or Hiperface encoder interface are a frequent source of axis faults that are misdiagnosed as controller failures.
The CANopen or EtherCAT communication backbone linking the LMC20A1307 to field devices should be verified for termination resistance, cable shielding continuity, and node address conflicts. A damaged CANopen termination resistor plug or a mis-addressed node can prevent the replacement controller from initializing the motion network correctly.
For cabinets integrating the LMC20A1307 with a Modicon M340 or M580 PLC via Ethernet or serial link, verify the communication module — such as a BMX NOE 0100 Ethernet module or BMX NOM 0200 serial module — is operating correctly and that IP addressing or Modbus node configuration is documented before the swap. Reconfiguration errors at this stage are a leading cause of extended post-replacement downtime.
Inspect I/O terminal blocks and wiring on the motion cabinet’s digital input/output section. Loose or corroded terminals on Schneider Electric NSYTRV or equivalent terminal strips can introduce signal noise that triggers spurious faults on the new controller. Replace any discolored or heat-stressed terminals as part of the corrective maintenance cycle.
If the cabinet includes signal isolators on analog reference or feedback channels — such as those used for speed reference or torque limit signals — verify isolation resistance and output accuracy. Degraded isolators can introduce offset errors that appear as tuning problems on the replacement LMC20A1307.
Finally, check cabinet cooling fans, filter mats, and thermal sensors. The LMC20A1307 is sensitive to sustained elevated temperatures. A blocked filter mat or failed fan in the control enclosure can reduce MTBF significantly and lead to repeat failures of the replacement unit within months of installation.
A well-structured spare parts kit for a Lexium Motion system should include the LMC20A1307 controller, at least one matched LXM servo drive, a replacement 24 VDC power supply module, a set of encoder feedback cables, CANopen termination plugs, and a supply of terminal block inserts — ensuring that any combination of concurrent faults can be resolved within a single maintenance window.
Site Replacement Workflow
Step 1 — Document before disconnecting. Photograph all wiring, label all connectors, and export the current motion program from the LMC20A1307 using SoMachine Motion or Lexium CT software before powering down. Confirm the firmware version and application program version are recorded.
Step 2 — Safe isolation. Isolate the control cabinet using the appropriate LOTO (Lockout/Tagout) procedure. Discharge the DC bus on all connected servo drives before handling the controller module. Verify zero-energy state with a calibrated multimeter.
Step 3 — Module removal. Release the DIN rail locking tab or rack mounting screws. Disconnect the communication bus connector, I/O connectors, and power supply connector in sequence. Note the physical orientation of all connectors — the LMC20 series uses keyed connectors on most interfaces, but verify before removal.
Step 4 — Replacement installation. Mount the LMC20A1307 replacement unit. Reconnect all connectors in reverse order. Verify that the communication bus termination is correctly set for the new unit’s position in the network topology.
Step 5 — Program restore and commissioning. Download the saved application program to the replacement controller. Verify axis parameters, cam profiles, and safety function configurations match the pre-fault baseline. Perform a slow-speed jog test on each axis before returning to full production speed.
Step 6 — Functional verification. Run a full production cycle at reduced speed, monitor for axis following errors, communication timeouts, and I/O response. Log the commissioning results and update the maintenance record with the replacement date, unit serial number, and warranty expiry.
This structured workflow minimizes re-work risk and ensures the replacement LMC20A1307 is commissioned to the same functional standard as the original unit, reducing the probability of a repeat fault within the warranty period.
Spare Parts Support FAQ
Q1: Is the LMC20A1307 a direct drop-in replacement for the existing unit in my Lexium Motion cabinet?
In the majority of standard Lexium Motion configurations, the LMC20A1307 is a direct hardware replacement. The application program, axis parameters, and communication configuration are stored in the controller’s non-volatile memory or can be restored from a project backup. Firmware version compatibility should be verified against your SoMachine Motion project file before commissioning. Contact our technical team with your existing firmware version for confirmation prior to ordering.
Q2: What pre-shipment testing is performed on the LMC20A1307 before dispatch?
Each LMC20A1307 unit undergoes a functional power-on test, communication interface verification, and visual inspection for physical damage before shipment. Units are packed in anti-static packaging with desiccant to prevent moisture ingress during transit. A test report is available upon request for quality-critical procurement processes.
Q3: What does the 12-month warranty cover, and how is a warranty claim processed?
The 12-month warranty covers manufacturing defects and functional failure under normal operating conditions. It does not cover damage caused by incorrect installation, overvoltage events, or environmental contamination beyond the unit’s rated IP class. To initiate a warranty claim, contact sale@ninermas.com with the order reference, unit serial number, and a description of the fault. Replacement or repair will be arranged within the agreed service timeline.
Q4: Can you support long-term or repeat supply of the LMC20A1307 for ongoing maintenance programs?
Yes. NINERMAS maintains sourcing relationships that support repeat and scheduled procurement of Schneider Electric Lexium spare parts including the LMC20A1307. For customers managing multi-site maintenance programs or annual shutdown schedules, we can discuss reserved stock arrangements, blanket purchase orders, and priority dispatch agreements. Contact our team at sale@ninermas.com or +0086 187 5021 5667 to discuss your supply requirements.
| Product Series | Lexium |
|---|---|
| Country of Origin | FR |
Catalog Continuation
More Schneider Electric modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
Catalog Continuation
Alternative parts within PLC & Industrial Automation Modules.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
SKU: FB900 8N-4*4NN5/A1-F801/Y
RKC FB900 8N-4*4NN5/A1-F801/Y Retrofit Temperature Controller
SKU: 9184-60118-D KTRON 9184-60118