Original Industrial Spare Part
Schneider 171CCC78010 Retrofit-Compatible Ethernet Module for Legacy Systems
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKU171CCC78010
- CategoryPLC & Industrial Automation Modules
- BrandSchneider Electric
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: Schneider 171CCC78010 Retrofit-Compatible Ethernet Module for Legacy Systems with SKU 171CCC78010.
Schneider 171CCC78010 Retrofit-Compatible Ethernet Module for Legacy Systems
The Schneider Electric 171CCC78010 is a Modicon Quantum series Ethernet TCP/IP communication module designed to provide high-speed network connectivity within legacy Quantum PLC rack architectures. As industrial facilities face increasing pressure to modernize aging distributed control systems while preserving existing program logic and field wiring, the 171CCC78010 has become a critical component in retrofit projects across manufacturing, energy, petrochemical, and water treatment sectors. This module enables seamless integration of legacy Quantum platforms into modern Ethernet-based supervisory networks, extending the operational life of installed systems without requiring a full control system replacement.
The 171CCC78010 supports Modbus TCP/IP and Ethernet I/P communication protocols, allowing it to interface with SCADA systems, historian servers, and HMI terminals over standard 10/100 Mbps Ethernet infrastructure. Its compatibility with the Modicon Quantum backplane — including the 140XBP01600 and 140XBP01000 series rack assemblies — means it can be installed directly into existing rack slots without mechanical modification. Engineers planning a retrofit must verify available rack slot positions, confirm backplane bus compatibility, and review the module’s IP address configuration requirements before installation.
Upgrade Compatibility Table
| Parameter | 171CCC78010 Specification | Retrofit Consideration |
|---|---|---|
| Communication Protocol | Modbus TCP/IP, Ethernet I/P | Verify SCADA/HMI protocol compatibility before migration |
| Network Speed | 10/100 Mbps Auto-negotiation | Compatible with standard managed switches; confirm port settings |
| Rack Compatibility | Modicon Quantum 140XBP series backplanes | Confirm available slot position and bus segment assignment |
| Power Consumption | Supplied via Quantum backplane bus | Verify 140CPS11420 or 140CPS12420 power supply capacity |
| IP Configuration | Static IP via rotary switches or software | Document existing network topology before reconfiguration |
| HMI Compatibility | Modbus TCP/IP to XBTGT and Magelis series HMI | Update HMI communication driver and IP address mapping |
| Programming Interface | Unity Pro / ProWORX compatible | Backup existing program before module swap |
| Installation Format | Single-slot Quantum rack module | Confirm physical slot clearance and adjacent module spacing |
| Warranty | 12-Month Warranty | Pre-shipment functional test included; documentation provided |
Retrofit Planning for Existing Automation Systems
Successful integration of the 171CCC78010 into an existing Modicon Quantum control system requires a structured pre-installation assessment. Engineers should begin by auditing the current rack configuration, identifying the CPU module in use — typically a 140CPU67160 or 140CPU65150 — and confirming the available I/O budget and backplane slot assignments. The 171CCC78010 occupies a single slot on the Quantum backplane and draws power directly from the rack bus, so the installed power supply module, such as the 140CPS11420 or 140CPS12420, must have sufficient reserve capacity to support the additional communication load.
In systems where the existing communication infrastructure relies on older 140NOE77100 or 140NOE77101 Ethernet modules, the 171CCC78010 can serve as a direct functional replacement or supplementary network node. Before swapping modules, technicians should export the current Unity Pro or ProWORX project file, document all Modbus TCP/IP device addresses, and record the IP configuration of the outgoing module. This ensures that the replacement module can be configured to maintain continuity with existing SCADA polling cycles and historian data collection without disrupting upstream supervisory systems.
For systems that include distributed I/O over RIO (Remote I/O) networks, the 171CCC78010 works alongside 140CRA93100 RIO head adapters and associated I/O modules such as the 140ACI03000 analog input module and 140DDI35300 digital input module. When the retrofit scope includes expanding I/O capacity, additional 140DDO35300 digital output modules or 140AVO02000 analog output modules can be added to existing RIO drops without requiring changes to the Ethernet communication configuration. This modularity is a key advantage of the Quantum platform for phased retrofit projects.
HMI integration is another critical checkpoint. Facilities running XBTGT5330 or other Magelis GT series operator panels connected via Modbus TCP/IP must update the HMI communication driver configuration to reflect the new module’s IP address and, if applicable, any changes to the Modbus device address map. In multi-panel installations, each HMI must be individually reconfigured and tested against live PLC data before the system is returned to production. Programming cable connections using TCSEGPA23F14F or equivalent Ethernet crossover cables are typically used during commissioning to verify module response and confirm network connectivity before integration into the plant LAN.
Downtime Control During System Migration
Minimizing unplanned downtime is the primary operational concern during any Quantum platform retrofit. The 171CCC78010 replacement process is designed to be executed during a planned maintenance window, with the target of completing the physical swap, IP reconfiguration, and communication verification within a single shift. To achieve this, all preparatory steps — including program backup, network documentation, IP address reservation, and HMI driver update — should be completed before the maintenance window begins.
The original PLC program logic stored in the 140CPU67160 or equivalent CPU module is not affected by replacing the communication module, provided the CPU retains power throughout the swap. In rack configurations where a redundant power supply is installed, the 171CCC78010 can be replaced without a full rack power-down, depending on the specific rack and slot assignment. Engineers should consult the Quantum hardware reference manual and confirm hot-swap eligibility for the specific slot before proceeding without a controlled shutdown.
After physical installation, the module’s rotary IP address switches should be set to match the documented network configuration, or the IP address should be assigned via Unity Pro’s I/O configuration tool if software-based addressing is used. A ping test from the engineering workstation confirms basic network connectivity, followed by a Modbus TCP/IP read test using a diagnostic tool to verify that the module is responding correctly to polling requests from the SCADA system. Once communication is confirmed, the HMI panels should be tested for live data display before the system is returned to automatic control mode.
Retrofit Support FAQ
Q1: Is the 171CCC78010 a direct replacement for the 140NOE77101?
The 171CCC78010 and 140NOE77101 are both Ethernet TCP/IP communication modules for the Modicon Quantum platform and share functional compatibility for Modbus TCP/IP applications. However, they differ in firmware version, IP configuration method, and supported feature sets. A direct slot-for-slot replacement is generally feasible, but engineers should verify Unity Pro project compatibility and update the I/O configuration section to reflect the new module type before downloading the updated program to the CPU.
Q2: What pre-shipment testing is performed on the 171CCC78010?
Each 171CCC78010 unit supplied by NINERMAS undergoes functional pre-shipment testing, including power-on verification, Ethernet port connectivity check, and Modbus TCP/IP communication response validation. A test report is available upon request. All units are covered by a 12-month warranty from the date of shipment, with technical support available for installation and commissioning queries.
Q3: Can the 171CCC78010 be used in a Quantum Hot Standby (HSBY) configuration?
The 171CCC78010 is compatible with Modicon Quantum Hot Standby architectures when installed in the appropriate rack slot and configured according to the HSBY system requirements. In HSBY systems, both the primary and standby racks must be equipped with identical communication modules to ensure seamless failover. Engineers should verify the HSBY configuration guide for slot assignment rules and confirm that the Unity Pro HSBY project is updated to include the replacement module before commissioning.
Q4: What is the lead time and stock availability for the 171CCC78010?
NINERMAS maintains reserved inventory of the 171CCC78010 to support urgent retrofit and breakdown replacement requirements. Standard lead time for in-stock units is 3–5 business days for international shipment. For projects requiring multiple units or long-term supply commitments, NINERMAS offers reserved stock programs to guarantee availability and protect against extended lead times from the open market. Contact our sales team to confirm current stock levels and arrange a supply agreement.
| Product Series | Modicon Quantum |
|---|---|
| Country of Origin | FR |