Original Industrial Spare Part
RITTAL SK3325024 Retrofit-Compatible Fan Filter for Legacy Systems
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKUSK3325024
- CategoryPLC & Industrial Automation Modules
- BrandRITTAL
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: RITTAL SK3325024 Retrofit-Compatible Fan Filter for Legacy Systems with SKU SK3325024.
RITTAL SK3325024 Retrofit-Compatible Fan Filter for Legacy Systems
The RITTAL SK3325024 is a ruggedized fan filter module engineered for industrial enclosure thermal management in demanding environments. As legacy control cabinets age and original cooling components reach end-of-life, the SK3325024 provides a dimensionally compatible, electrically equivalent retrofit solution that allows maintenance teams to restore enclosure climate control without redesigning the cabinet layout or replacing the entire enclosure assembly. This module is widely deployed in process automation, machine tool control, power distribution, and utility infrastructure applications where continuous uptime and thermal stability are non-negotiable.
For facilities operating aging RITTAL TS 8, SE 8, or AE series enclosures, the SK3325024 integrates directly into existing cutout dimensions, preserving the original IP54 protection rating and maintaining airflow performance consistent with the original specification. Engineers responsible for spare parts lifecycle planning will find this module a reliable long-term stocking option, particularly for multi-cabinet installations where standardizing on a single fan filter SKU reduces procurement complexity and simplifies preventive maintenance scheduling.
Upgrade Compatibility Table
| Parameter | SK3325024 (This Unit) | Retrofit Notes |
|---|---|---|
| Cutout Dimensions | Standard RITTAL 119 × 119 mm | Compatible with TS 8, SE 8, AE series cutouts; no panel modification required |
| Supply Voltage | 230 V AC / 115 V AC (model-dependent) | Verify terminal block voltage rating before wiring; use existing cable if gauge is adequate |
| Airflow Performance | Rated m³/h per RITTAL specification | Confirm thermal load calculation has not changed since original installation |
| Protection Rating | IP54 (with filter mat installed) | Replace filter mat (SK 3329.100 or equivalent) at installation to restore full IP rating |
| Mounting Interface | Snap-fit / screw-fixed flange | Retain original mounting screws; check torque specification in RITTAL installation guide |
| Communication / Control | Standalone (no bus interface) | If integrating with RITTAL CMC III or RiDiag monitoring, use existing sensor wiring path |
| Replacement Compatibility | Direct replacement for SK3325.024 legacy part number | Cross-reference against SK3325.100, SK3325.200 series for airflow variant selection |
| Commissioning Requirement | Plug-and-play; no software configuration | Verify fan rotation direction and airflow path (intake vs. exhaust) before closing cabinet |
| Warranty | 12-Month Warranty — covers manufacturing defects; pre-shipment functional test included | |
Retrofit Planning for Existing Automation Systems
Replacing a fan filter module in an active control cabinet requires more than a simple component swap. In installations where the SK3325024 is mounted on enclosures housing Siemens SIMATIC S7-300 or S7-400 PLCs, ABB AC500 controllers, or GE Fanuc Series 90-30 racks, thermal management directly affects CPU operating temperature and long-term reliability. Before scheduling the replacement, maintenance engineers should audit the enclosure’s internal heat load — accounting for power supplies such as the RITTAL PSU5000 series, I/O modules, communication processors, and any installed drives or soft starters.
In cabinets running Profibus DP or Modbus RTU networks, the fan filter replacement window should be coordinated with a planned communication link check. Profibus DP repeaters and RS-485 isolators installed in the same enclosure are sensitive to temperature excursions, and a failed fan filter that has been running degraded for weeks may have already caused intermittent communication faults. Replacing the SK3325024 alongside a filter mat refresh and a Profibus segment test reduces the risk of residual faults after the maintenance window closes.
For enclosures containing RITTAL DK 7080 or TS 8 series 19-inch rack systems with installed patch panels, UPS modules, or Ethernet switches, the airflow path must be re-verified after the new fan filter is seated. Rack-mounted equipment often creates internal airflow obstructions that were not present when the original fan filter was specified. A simple smoke pencil test or thermal camera scan after installation confirms that hot spots have been eliminated before the cabinet door is closed and the system is returned to service.
Where enclosures also house RITTAL CMC III monitoring units or third-party temperature sensors connected to a SCADA system, the maintenance record should be updated to reflect the fan filter replacement date and the new filter mat installation. This supports predictive maintenance scheduling and ensures that the next filter mat replacement interval is correctly calculated from the current service date rather than the original installation date.
In multi-cabinet installations — such as motor control centers (MCCs) or distributed control system (DCS) marshalling cabinets — standardizing on the SK3325024 across all enclosures simplifies spare parts inventory. A single stocked SKU covers multiple cabinet positions, reducing the risk of a cooling failure causing an unplanned shutdown while waiting for a non-stocked part. Facilities with 10 or more enclosures of the same series should consider maintaining a minimum buffer stock of two to four units per site.
Downtime Control During System Migration
Fan filter replacement on a live control cabinet can be executed with minimal disruption when planned correctly. The SK3325024 is designed for tool-assisted removal and reinstallation without requiring the enclosure to be de-energized, provided that the internal wiring harness has sufficient slack to allow the module to be disconnected and reconnected at the terminal block without disturbing adjacent wiring. Before beginning work, the maintenance technician should photograph the existing wiring arrangement and confirm that the replacement unit’s terminal designations match the original.
For cabinets where a brief power interruption to the fan circuit is unavoidable, the replacement should be scheduled during a planned process pause or shift changeover. In continuous process environments — such as chemical plants, water treatment facilities, or power generation stations — even a five-minute enclosure opening requires a formal permit-to-work and a thermal risk assessment. The SK3325024’s fast installation profile (typically under 15 minutes for an experienced technician) minimizes the exposure window and reduces the risk of condensation ingress during the open-cabinet period.
After installation, the technician should confirm that the fan is operating at rated speed, that the filter mat is correctly seated and not obstructing airflow, and that the enclosure door seals are intact. A 30-minute post-installation thermal soak — monitoring internal temperature via the CMC III or a handheld IR thermometer — confirms that the enclosure is returning to its normal operating temperature band before the maintenance record is closed. All replacement activities, including the filter mat batch number and the technician’s sign-off, should be logged in the site’s CMMS for traceability.
Retrofit Support FAQ
Q1: Is the SK3325024 a direct drop-in replacement for the original SK3325.024 part number?
Yes. The SK3325024 is the current catalog designation for the SK3325.024 legacy part number. The cutout dimensions, mounting flange, and electrical connections are identical. No panel modification or adapter bracket is required for standard RITTAL TS 8, SE 8, and AE series enclosures.
Q2: What pre-shipment testing is performed on each unit?
Each SK3325024 unit undergoes a functional run test prior to dispatch, confirming motor start, rated airflow, and electrical continuity. A test record is available upon request. All units are covered by a 12-month warranty against manufacturing defects from the date of shipment.
Q3: Can this unit be integrated with RITTAL CMC III enclosure monitoring?
The SK3325024 is a standalone fan filter module without a native bus interface. Integration with RITTAL CMC III is achieved through the CMC III’s temperature and humidity sensors, which monitor enclosure conditions independently of the fan filter. If fan failure detection is required, a current monitoring relay wired to the fan circuit provides a discrete alarm output compatible with most SCADA and BMS systems.
Q4: What is the recommended filter mat replacement interval, and is the filter mat included?
RITTAL recommends inspecting the filter mat every three to six months depending on ambient dust levels, with replacement typically required annually in standard industrial environments. The filter mat (SK 3329.100 series or equivalent) is not included with the SK3325024 fan filter module and should be ordered separately. Maintaining a stock of replacement filter mats alongside the fan filter unit ensures that the full IP54 protection rating is restored at each service interval.
| Product Series | Legacy |
|---|
Catalog Continuation
More RITTAL modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
SKU: SCM17EG1-R RGB/DVI SM 6450.160
Rittal SCM17EG1-R Spare Part for Industrial Maintenance
Catalog Continuation
Alternative parts within PLC & Industrial Automation Modules.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
SKU: 4-AXIS BXI4/2-01-B
BERKELEY BXI4/2-01-B Retrofit-Compatible Motion Controller
SKU: METEOR/RGB PCI 571-03
Matrox METEOR/RGB PCI 571-03 Service-Ready Spare Part