Original Industrial Spare Part
469-P5-HI-A20-T-H GE Multilin Motor Management Relay | Original Spare Parts
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKU469-P5-HI-A20-T-H
- CategoryPLC & Industrial Automation Modules
- BrandGE
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: 469-P5-HI-A20-T-H GE Multilin Motor Management Relay | Original Spare Parts with SKU 469-P5-HI-A20-T-H.
469-P5-HI-A20-T-H — GE Multilin Motor Management Relay | Industrial-Grade Motor Protection
As a procurement manager sourcing critical spare parts for continuous-process facilities, you need components that are 100% Brand New and Factory Sealed — no compromises. The 469-P5-HI-A20-T-H from GE Multilin is a precision-engineered Motor Management Relay purpose-built for medium-to-large AC motors operating in the harshest industrial environments. This Original New unit delivers advanced thermal modeling, multi-protocol communication, and comprehensive fault diagnostics within a single robust enclosure. Every unit of the 469-P5-HI-A20-T-H shipped from our inventory is verified 100% Original and Brand New, factory-sealed and traceable to GE Multilin’s original manufacturing documentation — meeting the highest E-E-A-T standards demanded by industrial procurement teams worldwide.
Downtime in motor-driven processes costs thousands per hour. The 469-P5-HI-A20-T-H addresses this directly: its harsh environment conformal coating (H suffix) shields internal electronics from salt spray, condensation, and corrosive atmospheres — a persistent pain point in offshore, chemical, and mining installations. Paired with 12 RTD input channels and advanced thermal overload algorithms, this relay identifies thermal stress before it becomes a failure event. Target industries include Oil & Gas, Power Generation, Water Treatment, and Heavy Manufacturing — anywhere that motor reliability is non-negotiable.
With dual-port Modbus RTU and DNP 3.0 communication (A20 option), seamless SCADA integration is standard, not an afterthought. Contact our team today for pricing, lead time, and datasheet access.
Typical Application Scenarios
The 469-P5-HI-A20-T-H excels across demanding sectors where motor failure carries severe operational and safety consequences:
- Oil & Gas: Compressor and pump motors on offshore platforms where salt-laden air and humidity demand conformal-coated protection electronics.
- Power Plants: Boiler feed pumps and cooling tower fan motors requiring continuous thermal monitoring and trip-circuit supervision (T suffix).
- Mining & Minerals: Conveyor drives and crusher motors in dusty, vibration-intensive environments where bearing temperature trending prevents catastrophic failures.
- Chemical Processing: Reactor agitators and centrifuge drives in corrosive atmospheres — the conformal coating provides a critical barrier against chemical vapor ingress.
- Water & Wastewater: Large submersible and surface pump motors in municipal systems requiring 24/7 unattended operation with remote SCADA visibility via Modbus RTU.
Core Features & Technical Advantages
- Robust Conformal Coating (H): Factory-applied harsh environment protection rated for salt spray, high humidity, and corrosive atmospheres — extends relay service life in extreme installations.
- Precision Thermal Modeling: Advanced thermal overload algorithms combined with 12 RTD input channels deliver real-time winding and bearing temperature tracking, enabling predictive maintenance strategies.
- Heavy-Duty Communication (A20): Dual-port RS-232/RS-485 supporting Modbus RTU and DNP 3.0 protocols — integrates natively with DCS, SCADA, and PLC System architectures without additional gateways.
- Enhanced 40-Character LCD (HI): High-information display provides on-panel access to metering, event logs, and configuration — reducing commissioning time and field troubleshooting effort.
- Trip Circuit Supervision (T): Continuous monitoring of the trip circuit integrity ensures the relay can actually operate when a fault occurs — a critical requirement for SIS-adjacent applications.
- Broad CT Compatibility (P5): 5A nominal CT input accommodates standard protection CT configurations across medium-voltage switchgear without additional interposing CTs.
Technical Specifications & Selection Guide
| Specification | Value |
|---|---|
| Model Number | 469-P5-HI-A20-T-H |
| Series | GE Multilin 469 Motor Management |
| CT Input Rating | 5A nominal (P5) |
| Display | 40-character backlit LCD (HI) |
| Power Supply | 90-264V AC / 100-300V DC |
| Communication Ports | Dual RS-232 / RS-485 (A20) |
| Protocols | Modbus RTU, DNP 3.0 |
| RTD Inputs | 12 channels |
| Digital Inputs | 8 programmable |
| Output Relays | 7 Form-A + 1 Form-C |
| Trip Circuit Supervision | Yes (T suffix) |
| Conformal Coating | Harsh environment (H suffix) |
| Operating Temperature | -40°C to +70°C |
| Certifications | UL, CSA, CE, IEC 61850 |
| Mounting | Panel mount, standard cutout |
| Condition | 100% Brand New and Factory Sealed |
Selection Tip: Choose the 469-P5-HI-A20-T-H when your application requires: (1) harsh environment protection, (2) dual-protocol SCADA communication, (3) trip circuit supervision, and (4) 5A CT inputs. For 1A CT configurations, consult our team for the P1 variant.
Logistics & Professional Service
- Condition: 100% Original and Brand New — factory sealed with full GE Multilin traceability documentation available on request.
- Warranty: 1-Year warranty covering manufacturing defects and component failures from date of shipment.
- Shipping: 2-Day expedited shipping available for in-stock units; global freight to all major industrial regions.
- EOL Support: We maintain inventory of legacy and end-of-life GE Multilin Control Module and relay products — supporting brownfield upgrades and emergency replacements.
- Documentation: Datasheet, wiring diagrams, and firmware release notes available upon request prior to purchase.
- Technical Support: Pre-sales application engineering and post-sales commissioning guidance provided by our industrial automation specialists.
FAQ — Frequently Asked Questions
Q: What is the lead time for the 469-P5-HI-A20-T-H?
A: For in-stock units, orders are typically dispatched within 1-2 business days with 2-day expedited shipping options available globally. For bulk orders or special configurations, lead time is confirmed at the time of quotation. Contact us with your required delivery date and we will prioritize accordingly.
Q: Can you provide a Datasheet or wiring diagram for the 469-P5-HI-A20-T-H?
A: Yes. The official GE Multilin 469 Motor Management Relay instruction manual, datasheet, and wiring diagrams are available upon request. Simply contact our team with your inquiry and we will provide the documentation package before purchase.
Q: Is this unit 100% original from GE Multilin?
A: Absolutely. Every 469-P5-HI-A20-T-H we supply is 100% Original and Brand New, sourced directly from authorized channels. Factory seals are intact and traceability documentation is available for quality-critical procurement processes.
Q: What is the difference between the H suffix and standard 469 models?
A: The H suffix denotes factory-applied harsh environment conformal coating, providing protection against salt spray, condensation, and corrosive vapors. Standard models lack this coating and are not recommended for offshore, chemical, or high-humidity installations.
Q: Does the 469-P5-HI-A20-T-H support IEC 61850 communication?
A: The base A20 option provides Modbus RTU and DNP 3.0. IEC 61850 compatibility depends on firmware version — please contact us to confirm compatibility with your specific substation automation or DCS platform.
Q: Can this relay be used in a Safety Instrumented System (SIS)?
A: The 469-P5-HI-A20-T-H includes trip circuit supervision (T suffix) which is a key requirement for SIS-adjacent motor protection. For full SIS integration, consult your functional safety engineer to confirm SIL rating requirements against the relay’s certified capabilities.
© 2026 NINERMAS COMPANY LIMITED. All rights reserved. Original Source: https://ninermas.com | Contact: sale@ninermas.com | +0086 187 5021 5667
| Product Series | Multilin |
|---|---|
| Country of Origin | US |
Catalog Continuation
More GE modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
SKU: DSC200SHVIG1BHD
Buy GE DSC200SHVIG1BHD Gate Driver Board | EX2100 Excitation
SKU: F35N00HKHF8LH67MXXPXXU8LWXX
GE F35N00HKHF8LH67MXXPXXU8LWXX F135 Naval Engine | Original Spare Parts
SKU: 745-W2-P5-G5-HI-A-L-R-E-H
GE Multilin 745-W2-P5-G5-HI-A-L-R-E-H | Industrial Safety & Performance Component
Catalog Continuation
Alternative parts within PLC & Industrial Automation Modules.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
Reviews
There are no reviews yet.