How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: Phoenix Contact CM50-PS-120-230AC/24DC/2.5/F Retrofit Power Supply with SKU CM50-PS-120-230AC/24DC/2.5/F.
Phoenix Contact CM50-PS-120-230AC/24DC/2.5/F Retrofit-Compatible Power Supply for Legacy Control Systems
The Phoenix Contact CM50-PS-120-230AC/24DC/2.5/F is a DIN rail-mounted power supply module designed for the CM50 modular terminal system. Accepting a wide-range AC input of 120–230 V AC and delivering a regulated 24 V DC output at 2.5 A (60 W), this unit is a direct retrofit solution for aging control cabinets, legacy PLC racks, and distributed I/O panels that depend on stable low-voltage DC bus power. Whether you are replacing a failed unit in a running production line or planning a phased modernization of an older automation system, the CM50-PS-120-230AC/24DC/2.5/F provides a reliable, pre-tested drop-in option with minimal rewiring and no firmware changes required.
Upgrade Compatibility Table
| Parameter | CM50-PS-120-230AC/24DC/2.5/F | Retrofit Notes |
|---|---|---|
| Input Voltage | 120–230 V AC, 50/60 Hz | Compatible with both 110 V and 230 V mains; verify local supply voltage before installation |
| Output Voltage | 24 V DC ± 1% | Matches standard 24 VDC bus used across CM50, Inline, and Axioline terminal families |
| Output Current | 2.5 A (60 W) | Confirm total downstream I/O load; add CM50-PS-120-230AC/24DC/5/F if load exceeds 2.5 A |
| Mounting | DIN rail (35 mm TS 35) | Direct replacement on existing DIN rail; no bracket modification required |
| Terminal Interface | CM50 push-in terminal block | Verify conductor cross-section (0.2–4 mm²); re-use existing ferrule-terminated wires where possible |
| Communication Compatibility | Power segment only; no fieldbus dependency | No impact on PROFIBUS, PROFINET, or Modbus TCP segments; safe to replace under partial shutdown |
| Replacement Recommendation | Direct drop-in for CM50 series power modules | Also compatible as auxiliary supply for legacy Inline IL BK PN/ME and Axioline F backplane segments |
| Commissioning Focus | Output voltage trim, load test, LED status check | Confirm 24 V DC at bus terminals before reconnecting I/O modules |
| Warranty | 12-Month Warranty — Pre-shipment functional test included on every unit | |
Retrofit Planning for Existing Automation Systems
When integrating the CM50-PS-120-230AC/24DC/2.5/F into an existing control architecture, the first step is a thorough power budget audit. Legacy control cabinets often house a mix of components — including CM50 digital input modules, CM50 analog output modules, signal isolators, and relay output terminals — all drawing from a shared 24 V DC bus. Before removing the old power supply, document the total current draw of every connected device. If the aggregate load approaches or exceeds 2.5 A, consider paralleling a second CM50-PS-120-230AC/24DC/5/F unit or redistributing loads across separate power segments.
Terminal wiring is the next critical checkpoint. The CM50 push-in terminal system accepts conductors from 0.2 to 4 mm². In older installations, wires may be terminated with open-end ferrules or even bare conductors. Before inserting wires into the new module, inspect each conductor for insulation integrity and confirm ferrule sizing. Mislabeled or reversed polarity connections on the 24 V DC output side can damage downstream CM50 digital output modules or analog input cards, so a polarity check with a calibrated multimeter is mandatory before energizing the bus.
For systems that also include a Phoenix Contact ILC 150 ETH or ILC 131 ETH/XC controller on the same backplane, the power supply replacement can typically be performed without halting the controller — provided the controller is powered from a separate, redundant supply. In such configurations, the CM50 I/O segment can be de-energized independently while the controller maintains its PROFINET or Ethernet/IP communication link to the SCADA layer. This approach significantly reduces planned downtime and avoids the need to reload the PLC program or re-establish HMI screen connections.
If the installation includes a Phoenix Contact RAD-2400-IFS wireless I/O module or a PSI-MOS-RS232/FO 850 E fiber optic converter for serial communication, these devices draw additional current from the 24 V DC segment. Account for their steady-state and inrush current requirements in the power budget. Similarly, any CM50 segment coupler or CM50 bus cover used to terminate the module row must be confirmed as mechanically compatible with the replacement unit’s housing width and locking tab geometry.
For installations where the CM50 rack also supports Phoenix Contact MINI MCR signal conditioners or MCR-SL isolation amplifiers, verify that the 24 V DC supply tolerance (±1%) is within the operating range specified for those signal processing modules. Tight voltage regulation is especially important in analog signal chains where a drifting supply rail can introduce offset errors in 4–20 mA or 0–10 V measurement loops.
Finally, if the control cabinet includes a Phoenix Contact TRIO-PS/1AC/24DC/10 or similar primary power supply feeding multiple sub-segments, confirm that the CM50-PS-120-230AC/24DC/2.5/F is connected to the correct AC distribution point and that upstream circuit protection (MCB rating, fuse type) is appropriate for the module’s 60 W maximum load.
Downtime Control During System Migration
Minimizing unplanned downtime is the primary concern in any live-system power supply replacement. For the CM50-PS-120-230AC/24DC/2.5/F, the recommended approach is a hot-swap preparation protocol: stage the replacement unit on the bench, perform a pre-power test at rated load using a dummy resistor bank, and confirm output voltage stability before bringing the unit to the cabinet. This pre-shipment functional test is standard practice for every unit shipped from our inventory, and the test record is available upon request.
On the day of replacement, coordinate with the process control team to identify a maintenance window — even a 15-minute window is sufficient for a straightforward CM50 power module swap if the wiring documentation is current. Photograph the existing terminal connections before disconnection. Use the CM50 module extraction tool to release the locking tab without damaging adjacent modules. Slide the new unit into position, reconnect terminals in sequence, and restore AC input power. Observe the green PWR LED on the module front face; a steady green indication confirms correct output voltage and no overload condition.
If the system uses a Phoenix Contact QUINT-PS/1AC/24DC/20 as the primary cabinet supply and the CM50 segment is a downstream sub-distribution point, the migration can be staged without affecting the primary supply or any other cabinet zones. This isolation capability is one of the key advantages of the CM50 modular architecture and should be leveraged to protect original program logic, preserve HMI screen states, and maintain fieldbus communication continuity throughout the replacement procedure.
After restoration, perform a 30-minute load monitoring cycle. Log output voltage, output current, and module temperature at 5-minute intervals. Any deviation beyond ±2% on the output voltage rail should trigger a re-inspection of terminal connections and downstream load distribution before returning the system to full production.
Retrofit Support FAQ
Q1: Is the CM50-PS-120-230AC/24DC/2.5/F a direct replacement for the original Phoenix Contact CM50 power supply?
Yes. The CM50-PS-120-230AC/24DC/2.5/F is designed as a form-fit-function replacement within the CM50 modular terminal system. It occupies the same DIN rail slot width, uses the same push-in terminal interface, and delivers the same 24 V DC / 2.5 A output as the original specification. No mechanical modification or rewiring of the downstream I/O segment is required for a standard replacement.
Q2: What commissioning steps are required after installation?
After mechanical installation and terminal reconnection, apply AC input power and verify the output voltage at the 24 V DC bus terminals using a calibrated multimeter. Confirm the PWR LED is steady green. Perform a functional test of all downstream CM50 I/O modules — including digital inputs, digital outputs, and any analog cards — by cycling through known I/O states from the PLC or HMI. Check that all fieldbus communication links (PROFINET, Modbus, or Ethernet/IP) are re-established and that no fault flags appear in the controller diagnostic buffer.
Q3: Does the unit ship with a pre-shipment functional test, and what warranty is provided?
Yes. Every CM50-PS-120-230AC/24DC/2.5/F unit in our inventory undergoes a pre-shipment functional test at rated output load before dispatch. The test confirms output voltage regulation, overload protection response, and thermal stability. All units are covered by a 12-month warranty from the date of shipment. Warranty claims are supported by our technical team via sale@ninermas.com.
Q4: Can this unit be used in applications outside the CM50 terminal system?
Yes, with appropriate engineering review. The CM50-PS-120-230AC/24DC/2.5/F delivers a standard 24 V DC / 2.5 A regulated output that is compatible with a wide range of industrial devices beyond the CM50 ecosystem — including Phoenix Contact Inline I/O segments, third-party relay modules, signal isolators, and 24 V DC-powered HMI panels. However, the push-in terminal interface is optimized for the CM50 connector pitch, so external wiring must be adapted accordingly. Confirm load requirements and terminal compatibility before deploying in non-CM50 applications.
| Product Series | Other series |
|---|---|
| Country of Origin | DE |
Catalog Continuation
More Phoenix Contact modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
SKU: QUINT-PS/1AC/24DC/ 5 2866750
Phoenix Contact QUINT-PS/1AC/24DC/5 Retrofit PSU Legacy Systems
SKU: QUINT-PS/1AC/48DC/5 2866679
Phoenix Contact QUINT-PS/1AC/48DC/5 2866679 Safety Power Supply
SKU: 2832564 FL HUB 16TX-ZF
PHOENIX CONTACT 2832564 FL HUB 16TX-ZF Safety-Reliable Ethernet Hub
Catalog Continuation
Alternative parts within PLC & Industrial Automation Modules.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.