Original Industrial Spare Part
X-Rite GM10032582-KIT Retrofit Color Calibration Kit
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKUGM10032582-KIT
- CategoryPLC & Industrial Automation Modules
- BrandX-RITE
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: X-Rite GM10032582-KIT Retrofit Color Calibration Kit with SKU GM10032582-KIT.
X-Rite GM10032582-KIT Retrofit-Compatible Color Calibration Kit: Legacy System Upgrade & Smooth Migration
The X-Rite GM10032582-KIT is a precision color calibration kit engineered for seamless integration into existing color measurement workflows. Whether you are replacing an end-of-life spectrophotometer module, upgrading a legacy quality-control station, or restoring a discontinued calibration reference standard, the GM10032582-KIT provides a verified drop-in solution that minimizes process disruption and protects your existing measurement infrastructure.
Industrial color measurement systems — particularly those built around X-Rite platforms such as the GretagMacbeth series, the X-Rite i1 family, and legacy Macbeth ColorChecker references — often reach end-of-life before the production lines they support. Sourcing a certified replacement kit like the GM10032582-KIT allows quality engineers to extend the operational life of their color-critical workflows without committing to a full system overhaul. This is especially relevant in automotive OEM paint matching, textile dyeing, plastics compounding, and graphic arts proofing environments where color consistency is a regulatory or contractual requirement.
Upgrade Compatibility Table
| Parameter | Legacy Reference | GM10032582-KIT | Notes |
|---|---|---|---|
| Form Factor | Original GretagMacbeth kit format | Identical physical format | No mechanical modification required |
| Calibration Standard | ISO 13655 / CIE compliant | ISO 13655 / CIE compliant | Full spectral compatibility |
| Interface / Connection | USB / RS-232 (instrument-dependent) | Compatible with existing instrument interfaces | Verify instrument firmware version |
| Software Compatibility | X-Rite ColorMaster, i1Profiler, NetProfiler | Compatible with current X-Rite software suite | Confirm software version ≥ minimum supported build |
| Replacement Scope | Discontinued GM-series calibration kits | Direct replacement | No reconfiguration of measurement geometry required |
| Commissioning | Manual white tile + black trap verification | Same procedure applies | Run full calibration cycle after installation |
| Warranty | — | 12-Month Warranty | Covered by NINERMAS quality assurance program |
Retrofit Planning for Existing Automation Systems
A successful retrofit begins well before the replacement kit arrives on-site. Engineers should audit the existing color measurement station to confirm which components remain serviceable and which require concurrent replacement. In a typical inline color QC cell, the GM10032582-KIT interfaces with the spectrophotometer head — commonly an X-Rite Ci64, Ci7800, or legacy SP60/SP62 series instrument — and the calibration data is managed through the X-Rite NetProfiler or i1Profiler software platform running on the plant network.
Before swapping the calibration kit, verify the condition of the white calibration tile and black trap insert. If either shows surface contamination, micro-scratching, or UV-induced yellowing, they must be replaced as part of the same service event. Attempting to calibrate a new kit against a degraded reference tile will introduce systematic measurement error that propagates across every subsequent color decision. In multi-instrument environments — for example, a production floor running several X-Rite Ci7600 or Ci7800 units networked to a central X-Rite NetProfiler server — all instruments should be recalibrated against the new GM10032582-KIT reference simultaneously to maintain inter-instrument agreement.
For facilities that have integrated color measurement into a broader automation cell — such as a robotic paint application line using a Fanuc or KUKA controller with a vision system feeding color delta-E data back to the PLC — the retrofit window should be coordinated with the PLC program logic review. Confirm that the color tolerance thresholds stored in the HMI recipe database still reflect the new calibration baseline. If the facility uses an OPC-UA or Profinet data link between the color measurement instrument and the SCADA layer, verify that the communication driver and tag mapping remain valid after the calibration update. In some legacy installations, the color instrument communicates via a dedicated RS-232 serial link to a data concentrator before bridging to Ethernet; this serial segment should be inspected for cable integrity and baud-rate configuration during the same maintenance window.
Spare parts planning should also account for consumable items that wear in parallel with the calibration kit: instrument aperture masks, fiber-optic light guides (where applicable), and the instrument’s internal lamp assembly. X-Rite Ci-series instruments use a pulsed xenon lamp with a rated service life; if the lamp is approaching end-of-life, replacing it concurrently with the GM10032582-KIT avoids a second unplanned downtime event within the same maintenance cycle. Similarly, if the facility operates an X-Rite 8200 or 8400 series benchtop spectrophotometer alongside portable units, the benchtop calibration standard should be updated at the same time to maintain cross-platform color consistency.
Downtime Control During System Migration
Minimizing production downtime during a calibration kit replacement requires a structured changeover plan. The recommended approach is to pre-stage the GM10032582-KIT and verify its physical condition — checking the white tile surface, the black trap, and the kit housing for transit damage — before the scheduled maintenance window opens. This pre-check takes approximately 15 minutes and eliminates the risk of discovering a defective component after the instrument has already been taken offline.
During the changeover, the existing calibration data file should be exported from the X-Rite software and archived before the new calibration cycle is initiated. This preserves the historical measurement baseline and allows engineers to perform a before/after comparison to quantify any drift that had accumulated in the legacy kit. If the color measurement station feeds pass/fail decisions to a downstream reject mechanism — for example, a pneumatic diverter gate on a packaging line — the automated reject logic should be placed in manual bypass mode during the calibration transition to prevent false rejects caused by the temporary measurement gap.
Once the GM10032582-KIT is installed and the full calibration cycle is complete, run a verification measurement against a set of physical color standards — ideally BCRA Series II ceramic tiles or equivalent traceable references — to confirm that the instrument is performing within specification before returning it to production service. Document the post-calibration verification results and retain them as part of the instrument’s calibration record. This documentation supports ISO 9001 and IATF 16949 audit requirements and provides traceability for any future color disputes with customers or suppliers.
For facilities with a redundant color measurement instrument, the preferred strategy is to complete the calibration kit replacement on the primary instrument first, validate its performance, and then transfer production measurement duties to the primary unit before servicing the secondary instrument. This rolling changeover approach keeps at least one calibrated instrument available at all times and reduces the total production exposure window to the duration of a single calibration cycle rather than the full replacement procedure.
Retrofit Support FAQ
Q1: Is the GM10032582-KIT a direct drop-in replacement for my existing GretagMacbeth calibration kit?
A: Yes. The GM10032582-KIT is designed as a form-fit-function replacement for the original GretagMacbeth GM-series calibration kits. No mechanical modification to the instrument or the calibration station is required. Confirm your instrument model and current software version before installation to ensure full compatibility.
Q2: What commissioning steps are required after installing the GM10032582-KIT?
A: After physical installation, perform a full calibration cycle using the white tile and black trap included in the kit. Run a verification measurement against a set of traceable color standards and compare the results against your established tolerance limits. Archive the post-calibration data file and update the instrument’s calibration record. Total commissioning time is typically 30–60 minutes depending on the number of instruments being calibrated.
Q3: Can the GM10032582-KIT be used with X-Rite software platforms such as i1Profiler and NetProfiler?
A: Yes. The GM10032582-KIT is compatible with the current X-Rite software suite including i1Profiler, NetProfiler, and ColorMaster. Ensure your software installation is updated to a supported build version. If you are running a legacy software version on an isolated plant network, contact your X-Rite service representative to confirm compatibility before proceeding.
Q4: What warranty coverage applies to the GM10032582-KIT supplied by NINERMAS?
A: All GM10032582-KIT units supplied by NINERMAS COMPANY LIMITED carry a 12-month warranty covering manufacturing defects and calibration standard integrity. Units are inspected and function-verified prior to shipment. In-stock units are available for immediate dispatch. For volume procurement or long-term spare parts program inquiries, contact our sales team directly.
| Product Series | Other series |
|---|
Catalog Continuation
Alternative parts within PLC & Industrial Automation Modules.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
SKU: 2-12V HPM5B6BEA1A1F1S235 QLZ 80 3D80-001918-12 MDC-01A
Power-One HPM5B6BEA1A1F1S235 Retrofit Power Supply for Legacy
SKU: VLB20105 V003048.B02