Original Industrial Spare Part
Siemens 6SE7033-5HH84-1HH0 Retrofit Power Supply Module
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKU6SE7033-5HH84-1HH0
- CategoryPLC & Industrial Automation Modules
- BrandSiemens
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: Siemens 6SE7033-5HH84-1HH0 Retrofit Power Supply Module with SKU 6SE7033-5HH84-1HH0.
Siemens 6SE7033-5HH84-1HH0 Retrofit-Compatible Power Supply Module for Legacy Drive Systems
The Siemens 6SE7033-5HH84-1HH0 is a ruggedized DC link power supply module designed for the SIMOVERT MASTERDRIVES MC and VC series — one of Siemens’ most widely deployed variable-speed drive platforms in heavy industrial environments. As the original MASTERDRIVES product line has reached end-of-life and spare parts availability from OEM channels continues to decline, the 6SE7033-5HH84-1HH0 has become a critical retrofit and replacement component for plant engineers managing aging drive cabinets in steel mills, cement plants, paper machines, water treatment facilities, and chemical processing lines.
NINERMAS supplies the 6SE7033-5HH84-1HH0 as a verified retrofit-compatible replacement unit, pre-tested prior to shipment and backed by a 12-month warranty. Each unit is inspected for DC bus integrity, gate driver function, thermal interface condition, and connector pin continuity before dispatch. Our inventory is maintained to support urgent breakdown orders and planned maintenance windows alike, with typical lead times of 3–7 business days for in-stock units.
Upgrade Compatibility Table
| Parameter | Details |
|---|---|
| Part Number | 6SE7033-5HH84-1HH0 |
| Brand / Series | Siemens / SIMOVERT MASTERDRIVES |
| Module Function | Ruggedized Power Supply / DC Link Module |
| Compatible Drive Platforms | SIMOVERT MASTERDRIVES MC, VC; SIMOVERT MASTERDRIVES Compact Plus |
| Replaces / Supersedes | Earlier 6SE70 series power supply variants with equivalent frame size and DC bus rating |
| Mounting / Installation | Rack-mount into MASTERDRIVES standard chassis; verify frame size and slot position against existing cabinet layout |
| Communication Compatibility | Compatible with PROFIBUS-DP via CBP2 communication board (6SE7090-0XX84-0FF5); verify firmware revision alignment |
| Backplane / Bus Interface | MASTERDRIVES internal DC bus bar; confirm bus bar torque spec and insulation condition before installation |
| Terminal Wiring | AC input terminals L1/L2/L3; DC output bus terminals; PE ground lug — verify conductor cross-section against original design |
| Cooling Requirement | Forced-air cooling via integrated fan or external cabinet ventilation; confirm airflow path is unobstructed |
| Commissioning Tool | STARTER software or DriveMonitor via USS/PROFIBUS; parameter set P-list backup recommended before swap |
| Pre-Shipment Testing | DC bus charge/discharge cycle, gate driver signal verification, thermal imaging |
| Warranty | 12 Months from date of shipment |
Retrofit Planning for Existing Automation Systems
Replacing the 6SE7033-5HH84-1HH0 in an operating plant requires a structured approach that accounts for the full drive cabinet ecosystem. In a typical MASTERDRIVES installation, the power supply module operates in close coordination with the inverter module (such as the 6SE7032-6EG84-1HH0 or 6SE7036-0EE85-1AA0), the rectifier unit, and the common DC bus. Before initiating a swap, engineers should confirm that the DC bus capacitor bank condition is acceptable — degraded capacitors in adjacent modules can cause the replacement unit to fail prematurely under load.
The control electronics in a MASTERDRIVES cabinet typically include a CU (Control Unit) board such as the 6SE7090-0XX84-0AB0, which holds the drive’s parameter memory and application logic. It is strongly recommended to perform a full parameter backup using DriveMonitor or STARTER software before any hardware intervention. This protects the P-list, setpoint ramps, torque limits, and PLC interface assignments that have been tuned over years of operation. If the CU board is also being replaced as part of a broader upgrade, the parameter file must be restored to the new board before the drive is energized.
For cabinets that include a SIMATIC S7-300 or S7-400 PLC communicating with the drive over PROFIBUS-DP, the GSD file and hardware configuration in STEP 7 or TIA Portal should be verified to ensure the drive’s DP address and telegram type (e.g., Standard Telegram 1 or 20) remain consistent after the module swap. A mismatch in telegram configuration will cause the PLC to report a drive fault immediately on startup. If the site is migrating from PROFIBUS to PROFINET as part of a broader modernization, a CBE20 communication board may be required in place of the CBP2, and the PLC program will need corresponding updates to the drive FB calls.
I/O wiring at the terminal strip — including analog speed references (0–10 V or 4–20 mA), digital enable signals, fault relay outputs, and encoder feedback from a 6FX2001 or 6FX8002 series cable — should be documented and photographed before disconnection. Terminal numbering on the replacement module should be cross-referenced against the original wiring diagram, as minor revisions between hardware generations can shift terminal assignments. Signal isolators or barriers installed upstream of the drive’s analog inputs should also be checked for correct output range and loop power compatibility.
If the cabinet includes an OP1S operator panel (6SE7090-0XX84-2FK0) or an external HMI running WinCC or ProTool, the drive’s parameter display and fault history screens should be verified after commissioning to confirm that the communication link between the panel and the new module is functioning correctly. In some installations, the OP1S is connected via the drive’s RS485 port, which requires the correct USS protocol settings to be restored from the parameter backup.
Physical installation space should be confirmed before ordering. The 6SE7033-5HH84-1HH0 occupies a specific frame width in the MASTERDRIVES chassis, and adjacent modules — including braking resistor units, line filters, or output reactors — must be temporarily removed or repositioned to allow safe extraction of the failed unit. Cabinet depth and cable management should also be assessed to ensure the replacement unit can be fully seated and secured without stressing the DC bus bar connections.
Downtime Control During System Migration
Minimizing production downtime during a power supply module replacement on a MASTERDRIVES drive is achievable with proper pre-planning. The most effective strategy is to stage the replacement during a scheduled maintenance window rather than responding reactively to a catastrophic failure. NINERMAS recommends maintaining at least one 6SE7033-5HH84-1HH0 as a cold standby spare in the plant’s MRO inventory, particularly for drives controlling critical process equipment such as main mill drives, kiln drives, or compressor trains where unplanned downtime carries significant production cost.
Before the maintenance window begins, the engineering team should prepare a swap checklist that includes: parameter file backup confirmation, DC bus discharge verification (minimum 5-minute wait after power-off before touching bus bars), torque specifications for bus bar bolts, photographic record of all wiring connections, and a functional test plan covering no-load run, ramp-up to operating speed, and load application. Having the STARTER software laptop and a USB-to-RS232 adapter or PROFIBUS PC adapter (such as the CP5711 or CP5512) on-site before the window begins eliminates delays during commissioning.
For drives that cannot be taken offline for extended periods, a parallel commissioning approach can be used: the replacement module is pre-configured and parameter-loaded on the bench using a test rig, then swapped into the cabinet with only the final wiring connections and a brief functional verification required on-site. This approach can reduce the live outage window to under two hours for an experienced team. NINERMAS can provide pre-tested units with customer-specific parameter sets loaded on request, subject to the customer supplying a verified parameter file in advance.
After the replacement is complete and the drive has been returned to service, a 24-hour monitoring period is recommended during which the drive’s fault log, DC bus voltage, output current, and thermal status are checked at regular intervals. Any anomalies — such as intermittent overcurrent faults, DC bus overvoltage trips, or unexpected thermal warnings — should be investigated before the drive is returned to full production load.
Retrofit Support FAQ
Q1: Is the 6SE7033-5HH84-1HH0 a direct drop-in replacement for my existing MASTERDRIVES power supply module?
In most cases, yes — provided the frame size, DC bus voltage rating, and cabinet slot configuration match your existing installation. We recommend confirming the exact variant suffix and hardware revision of the module being replaced before ordering. Our technical team can assist with cross-referencing your existing part number if you provide the full nameplate data.
Q2: What pre-shipment testing is performed on each unit?
Every 6SE7033-5HH84-1HH0 supplied by NINERMAS undergoes a pre-shipment test protocol that includes DC bus charge/discharge cycling, gate driver signal verification, insulation resistance check, and thermal imaging under load. A test report is available on request. Units are shipped with protective packaging to prevent transit damage to the DC bus terminals and connector pins.
Q3: Can you supply this module with a customer parameter set pre-loaded?
Yes. If you supply a verified STARTER or DriveMonitor parameter file (.par or .usp format), we can arrange for the parameter set to be loaded and verified on the unit prior to shipment. This service is available for orders with sufficient lead time. Please contact our technical sales team to discuss requirements.
Q4: What is the warranty coverage and what does it include?
All units supplied by NINERMAS carry a 12-month warranty from the date of shipment. The warranty covers manufacturing defects and component failures under normal operating conditions. It does not cover damage resulting from incorrect installation, overvoltage events, or operation outside the module’s rated parameters. Warranty claims are supported by our technical team, and replacement units can be dispatched on an advance exchange basis for critical applications.
| Product Series | SIMOVERT |
|---|---|
| Country of Origin | DE |
Catalog Continuation
More Siemens modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
SKU: 6AV6542-0CA10-0AX0
Siemens 6AV6542-0CA10-0AX0 Safety-Reliable HMI for Critical Sites
SKU: A5E00158600 6SE70 TP/EP60 CUVP-02
SIEMENS A5E00158600 6SE70 TP/EP60 CUVP-02 Safety-Reliable Power Module
SKU: 6SE7038-6EK84-1GF0
SIEMENS 6SE7038-6EK84-1GF0 Service-Ready Spare Part
SKU: 6ES5316-8FA12
Siemens 6ES5316-8FA12 Retrofit-Compatible Interface Module
Catalog Continuation
Alternative parts within PLC & Industrial Automation Modules.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
SKU: HDD02.2-W040N-HS12-01-FW FWA-DIAX04-ELS-05VRS-MS
Rexroth HDD02.2-W040N-HS12-01-FW Service-Ready Spare Part
SKU: I5DAE375F10010000S