Original Industrial Spare Part

Honeywell 51308112-100 LCN Coax Cable Components | TDC 3000 Network

Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.

SKU: 51308112-100 TSI & Rotating Machinery Monitoring Honeywell

RFQ Ready

Request pricing & availability

How Buyers Usually Use This Page

  • Confirm the exact part number and platform family before sending the quote request.
  • Use direct email when quantity, condition, and destination are already defined internally.
  • Switch to the broader brand or category archive when you need alternates nearby.

Series Navigation

Move through the most common platform families behind this part.

Honeywell 51308112-100 LCN Coax Cable Components — Reliable TDC 3000 Network Infrastructure

The Honeywell 51308112-100 LCN Coax Cable Components provide essential connectivity for Local Control Network (LCN) communication within Honeywell TDC 3000 distributed control systems. Engineered for high-reliability industrial environments, these coaxial cable components ensure robust data transmission between controllers, I/O modules, and operator stations across your DCS infrastructure.

Technical Specifications

Parameter Specification
Part Number 51308112-100
Product Type LCN Coaxial Cable Components
System Compatibility TDC 3000 DCS
Network Type Local Control Network (LCN)
Cable Type RG-11/U Coaxial
Impedance 75 Ohm
Operating Temperature -40 °C to +85 °C
Shielding Dual-layer braided shield
Connector Type BNC/F-Type compatible
Maximum Segment Length Varies by topology (up to 1000m)

Key Features & Benefits

  • TDC 3000 Optimized: Purpose-built for Honeywell’s proven distributed control architecture
  • High-Reliability Shielding: Dual-layer braided shield minimizes EMI/RFI interference in industrial environments
  • Extended Temperature Range: Operates reliably from -40 °C to +85 °C for harsh process areas
  • 75-Ohm Impedance: Matched impedance ensures signal integrity across extended network segments
  • Flexible Topology Support: Compatible with bus, star, and hybrid LCN configurations
  • Long Service Life: Industrial-grade construction withstands vibration, temperature cycling, and chemical exposure

Application Scenarios

The Honeywell 51308112-100 serves as critical infrastructure for TDC 3000 installations across diverse industrial sectors:

Process Control Networks: Establishes reliable LCN communication between field controllers and central operator stations. When building comprehensive TDC 3000 networks, combine with the Honeywell 51401570-100 TDC 3000 LCN Module for complete network node connectivity.

Distributed I/O Systems: Connects remote I/O racks to process controllers across plant floors. Pair with Honeywell 51305072-400 LCN A/B Input/Output Board to enable redundant communication paths for critical control loops.

UCN-LCN Bridge Installations: Supports network segmentation between Universal Control Network and Local Control Network layers. Deploy alongside the Honeywell 51404125-200 Enhanced Process Network Interface Module for seamless UCN-LCN data exchange.

Legacy System Upgrades: Enables network expansion and modernization of existing TDC 3000 installations without complete infrastructure replacement.

Complete TDC 3000 Network Solutions

Building robust TDC 3000 communication infrastructure requires coordinated selection of network components. The 51308112-100 coaxial cable components integrate seamlessly with complementary TDC 3000 modules to create reliable control networks.

For complete network installations, consider the Honeywell 4600136 UCN Cable for TDC 3000 DCS System for Universal Control Network segments, and the Honeywell 51201397-001 Control Cable for TDC 3000 UCN System for specialized control wiring requirements.

When implementing I/O link connectivity, the Honeywell 51202329-200 TDC 3000 IOTA Cable Assembly provides factory-terminated connections between controllers and field termination assemblies, while the Honeywell 51204042-200 I/O Link Interface Cable Set offers complete cable kits for rapid deployment.

System Integration & Compatibility

The 51308112-100 LCN coax components support both new installations and retrofit projects within existing TDC 3000 architectures. For network interface requirements, the Honeywell 51304511-100 Network Interface Module provides essential protocol conversion and network management capabilities.

When designing redundant network topologies, deploy the Honeywell 51506303-200 Enhanced Process Network Module to enable fault-tolerant communication paths that maintain control system availability during cable or module failures.

Installation Best Practices

Cable Routing: Maintain minimum 150mm separation from high-voltage power cables to minimize electromagnetic interference. Use dedicated cable trays or conduit for LCN coaxial runs.

Termination: Ensure proper impedance matching at all network endpoints using approved termination resistors. Unterminated segments can cause signal reflections and communication errors.

Grounding: Follow Honeywell’s grounding specifications to prevent ground loops while maintaining shield continuity. Single-point grounding is typically recommended for LCN segments.

Testing: Verify cable continuity, impedance, and shield integrity before energizing the network. Use time-domain reflectometry (TDR) to identify cable faults or impedance mismatches.

Frequently Asked Questions

Q: What is the maximum recommended cable length for LCN segments?
A: Maximum segment length depends on network topology and node count. Bus configurations typically support up to 1000 meters, while star topologies may extend further with proper repeaters.

Q: Can I mix different cable types within the same LCN network?
A: While technically possible, mixing cable types can introduce impedance mismatches. For optimal performance, use consistent cable specifications throughout each network segment.

Q: How do I identify cable faults in an operational LCN network?
A: Use TDR equipment to locate opens, shorts, or impedance discontinuities without disrupting network operation. Honeywell diagnostic tools can also identify communication errors that may indicate cable issues.

Q: Are these components compatible with Experion PKS systems?
A: The 51308112-100 is specifically designed for TDC 3000 LCN networks. Experion PKS uses different communication infrastructure, though TDC 3000 subsystems can integrate with Experion through appropriate gateway modules.

Q: What environmental factors affect cable performance?
A: Temperature extremes, chemical exposure, vibration, and electromagnetic interference can degrade cable performance. Proper routing, environmental protection, and periodic inspection maintain long-term reliability.

Q: What warranty coverage is provided?
A: All Honeywell 51308112-100 LCN Coax Cable Components include a comprehensive 12-month manufacturer warranty covering defects in materials and workmanship.

Why Choose Industrial Control Hub?

  • Genuine Honeywell Components: Factory-authorized distributor providing authentic TDC 3000 parts with full traceability
  • Technical Support: Experienced DCS specialists available for network design consultation and troubleshooting assistance
  • Comprehensive Inventory: Complete range of TDC 3000 network components, cables, and accessories for one-stop procurement
  • Fast Delivery: Expedited shipping options available for critical maintenance and project deadlines
  • 12-Month Warranty: Extended warranty coverage for complete peace of mind on every purchase

Order Your Honeywell 51308112-100 Today

Ensure reliable TDC 3000 network communication with genuine Honeywell LCN coaxial cable components. The 51308112-100 delivers the performance and durability your critical control systems demand.

For complete network solutions, explore our full range of TDC 3000 LCN modules and communication infrastructure components.

© 2025 INDUSTRIAL CONTROL HUB. All rights reserved.
Original Source: https://www.indctrlhub.com
Contact: sales@indctrlhub.com | +0086 18359243191

Product Series

Experion PKS (C200/C300)

Country of Origin

US

Reviews

There are no reviews yet.

Be the first to review “Honeywell 51308112-100 LCN Coax Cable Components | TDC 3000 Network”

Your email address will not be published. Required fields are marked

Catalog Continuation

Likely TDC 2000/3000 platform matches.

These parts are closer to the same platform family signaled by the current SKU and title, so buyers can validate continuity before sending a final RFQ.

Open this lane

Catalog Continuation

More Honeywell modules in the catalog.

Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.

Open this lane

Catalog Continuation

Alternative parts within TSI & Rotating Machinery Monitoring.

Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.

Open this lane

Industrial RFQ Support

Need a fast quote for a specific part number or system family?

Send your inquiry with brand, series, quantity, condition, and destination details. We will follow up on availability, lead time, and shipping options.

CallPhone MailEmail WAChat TopBack