Original Industrial Spare Part

Allen-Bradley 2711-T6C16L1 PanelView 600 Touchscreen HMI — New & Original

Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.

SKU: 2711-T6C16L1 PLC & Industrial Automation Modules Allen-Bradley (Rockwell)

RFQ Ready

Request pricing & availability

How Buyers Usually Use This Page

  • Confirm the exact part number and platform family before sending the quote request.
  • Use direct email when quantity, condition, and destination are already defined internally.
  • Switch to the broader brand or category archive when you need alternates nearby.

Series Navigation

Move through the most common platform families behind this part.

Allen-Bradley PanelView 600 2711-T6C16L1 | Reliable Automation Component

Field Application & Operational Analysis

From a Site Reliability Engineer’s perspective, the Allen-Bradley 2711-T6C16L1 is a mission-critical HMI asset that directly influences system availability on the production floor. The 2711-T6C16L1 delivers a 6.5-inch TFT color touchscreen interface with 640-480 VGA resolution, enabling operators to monitor real-time process data, manage alarms, and execute control commands with minimal latency — a decisive factor in preventing unplanned downtime across mission-critical automation environments.

Engineered for operational excellence in harsh industrial settings, the 2711-T6C16L1 carries a NEMA 4X / IP65 front-panel rating, providing robust resistance to dust ingress, water jets, and corrosive atmospheres. During installation, engineers should verify 24V DC supply stability within the 19.2-30V DC tolerance band and ensure panel cutout dimensions conform to Rockwell Automation specifications to maintain the IP65 seal integrity. Thermal management is equally important — ambient operating range is 0°C to 55°C, and adequate enclosure ventilation is mandatory to sustain long-term component reliability.

As a legacy PanelView 600 platform unit, the 2711-T6C16L1 has reached end-of-life (EOL) status in Rockwell’s current catalog, making certified new-original stock increasingly scarce. Procurement teams managing aging automation infrastructure are strongly advised to secure spare units proactively to eliminate sourcing risk and protect production continuity.

Key Operational Features

High-Availability Display: 6.5-inch TFT color touchscreen (640-480 VGA) with high-contrast rendering for reliable operator visibility under variable lighting conditions.
Dual RS-232 Serial Ports: Supports simultaneous DH-485 and DF1 protocol communication, enabling seamless integration with multiple Allen-Bradley PLC families without additional hardware.
Onboard SD Card Slot: Facilitates rapid application deployment, recipe management, and data logging — reducing maintenance turnaround time during system upgrades.
64 MB Flash / 32 MB DRAM: Sufficient memory architecture for complex HMI applications with trend displays, alarm histories, and multi-screen navigation.
NEMA 4X / IP65 Front Bezel: Industrial-grade ingress protection ensuring operational continuity in washdown, dusty, and chemically aggressive environments.
UL / cUL / CE Certified: Meets North American and European safety compliance standards, simplifying regulatory approval for new machine installations.

Maintenance & Performance Benchmarks

The 2711-T6C16L1 is architected to integrate across a broad spectrum of industrial network topologies. In small-scale standalone machine applications, it connects directly to MicroLogix or SLC 500 controllers via DF1 point-to-point RS-232 — a configuration that minimizes network complexity and reduces single points of failure. In mid-scale distributed architectures, the DH-485 port enables multi-drop communication with up to 32 nodes, supporting process optimization across interconnected machine cells without dedicated network switches.

For larger system integration scenarios, the terminal operates as a local operator station within a broader FactoryTalk View ME supervisory layer, providing localized I/O module status visualization while upstream SCADA systems handle enterprise-level data aggregation. Firmware maintenance is straightforward: application files are transferred via SD card, eliminating the need for dedicated programming cables during routine updates — a significant advantage for remote or hard-to-access panel installations. Mean Time Between Failures (MTBF) data from field deployments consistently positions this unit as a dependable component in 24/7 continuous-process environments.

Comprehensive Data Sheet

Attribute Technical Data
Full Model Number 2711-T6C16L1
Brand Allen-Bradley (Rockwell Automation)
Series PanelView 600
Display Size 6.5-inch TFT Color Touchscreen
Resolution 640 — 480 VGA
Flash Memory 64 MB
DRAM 32 MB
Communication Ports 2 — RS-232 (DH-485, DF1 protocols)
Storage Expansion SD Card Slot (up to 2 GB)
Input Voltage 24V DC nominal (19.2-30V DC range)
Operating Temperature 0°C to 55°C (32°F to 131°F)
Ingress Protection NEMA 4X / IP65 (front panel)
Mounting Style Panel Mount
Programming Software RSView32 Works / FactoryTalk View ME
Compatible Controllers ControlLogix, CompactLogix, MicroLogix, SLC 500
Certifications UL, cUL, CE
Country of Origin United States
Product Status EOL / Legacy — New & Original Stock Available

Professional Logistics & Sourcing Excellence

Every 2711-T6C16L1 unit dispatched from our facility is sourced from authorized distribution channels and ships in original factory packaging with full manufacturer labeling and protective materials intact — preserving component integrity from warehouse to panel. For time-sensitive production recovery scenarios, same-day dispatch is available on confirmed in-stock units when orders are placed before the daily cut-off time.

As an EOL / legacy automation component, global supply of the 2711-T6C16L1 is finite and diminishing. Our procurement network spans certified warehouses across North America, Europe, and Asia-Pacific, enabling us to fulfill urgent requirements for maintenance teams operating aging Allen-Bradley infrastructure. All units undergo pre-shipment functional verification, and export documentation — including commercial invoices, packing lists, and certificates of origin — is prepared to facilitate smooth customs clearance for international shipments. Worldwide express logistics via DHL, FedEx, and UPS ensures delivery timelines aligned with your maintenance schedule.

Engineering Support & FAQ

Q1: What is the correct installation sequence for the 2711-T6C16L1 in a new panel?
A: Begin by verifying panel cutout dimensions per Rockwell publication 2711-IN009. Mount the terminal and secure all eight panel-mount screws to the specified torque to maintain IP65 integrity. Connect 24V DC power, then establish RS-232 communication to the target PLC before powering on. Load the application via SD card or RSView32 programming cable and perform a full I/O module communication test prior to commissioning.

Q2: Which firmware versions are compatible with FactoryTalk View ME?
A: The 2711-T6C16L1 supports FactoryTalk View ME versions up to 5.10. For RSView32 environments, version 7.50 or later is recommended. Always verify firmware revision on the terminal’s System Information screen before deploying updated application files to avoid compatibility conflicts.

Q3: Can the 2711-T6C16L1 communicate with third-party PLCs or non-Rockwell devices?
A: Yes. Via the DF1 full-duplex protocol over RS-232, the terminal can interface with any third-party controller that supports DF1 — including select Siemens and Mitsubishi devices with appropriate protocol converters. DH-485 connectivity is limited to Allen-Bradley network nodes.

Q4: How is the warranty claim process handled for this unit?
A: All units carry a 12-month warranty from the date of shipment. To initiate a warranty claim, contact our technical support team at sale@ninermas.com with the unit serial number, purchase order reference, and a description of the observed fault. Replacement or repair is processed within 5-7 business days upon receipt of the defective unit at our service center.

Q5: What is the maximum SD card size supported, and which file formats are compatible?
A: The terminal supports SD cards up to 2 GB formatted in FAT16. Application files (.mer), data log files (.csv), and recipe files (.csv) are the primary supported formats. SDHC cards exceeding 2 GB are not recognized by the 2711-T6C16L1 firmware.

Q6: Is this terminal suitable for use in hazardous or classified locations?
A: The 2711-T6C16L1 is not rated for Class I Division 1 or ATEX Zone 1 hazardous locations in its standard configuration. For classified area installations, consult Rockwell Automation’s hazardous location HMI portfolio or implement appropriate purge-and-pressurization enclosure solutions.

© 2026 NINERMAS COMPANY LIMITED. All rights reserved. Original Source: https://ninermas.com | Contact: sale@ninermas.com | +0086 187 5021 5667

Product Series

Other Legacy / Discontinued Modules

Country of Origin

US

Reviews

There are no reviews yet.

Be the first to review “Allen-Bradley 2711-T6C16L1 PanelView 600 Touchscreen HMI — New & Original”

Your email address will not be published. Required fields are marked

Catalog Continuation

More Allen-Bradley (Rockwell) modules in the catalog.

Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.

Open this lane

Catalog Continuation

Alternative parts within PLC & Industrial Automation Modules.

Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.

Open this lane

Industrial RFQ Support

Need a fast quote for a specific part number or system family?

Send your inquiry with brand, series, quantity, condition, and destination details. We will follow up on availability, lead time, and shipping options.

CallPhone MailEmail WAChat TopBack