Original Industrial Spare Part

Allen-Bradley 1606-XLERED Redundancy Module | Original Spare Parts

Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.

SKU: 1606-XLERED PLC & Industrial Automation Modules Allen-Bradley (Rockwell)

RFQ Ready

Request pricing & availability

How Buyers Usually Use This Page

  • Confirm the exact part number and platform family before sending the quote request.
  • Use direct email when quantity, condition, and destination are already defined internally.
  • Switch to the broader brand or category archive when you need alternates nearby.

Series Navigation

Move through the most common platform families behind this part.

1606-XLERED Redundancy Module — Allen-Bradley Original Spare Parts for Industrial Automation

As a Procurement Manager sourcing critical components for continuous-process facilities, you understand that a single point of power failure can cascade into catastrophic downtime. The Allen-Bradley 1606-XLERED is a factory-sealed, 100% Brand New and Factory Sealed redundancy module engineered to eliminate that risk. Designed specifically for the 1606-XLS series power supply platform, the 1606-XLERED employs a diode-OR architecture that automatically load-shares between two independent 24V DC sources — ensuring your PLC System and Control Module assets remain energized without interruption.

In demanding environments such as Oil & Gas processing skids, pharmaceutical batch control networks, and automotive body-shop robotics, the consequences of unplanned shutdowns extend far beyond lost production. The 1606-XLERED addresses these pain points by providing sub-10ms failover with zero voltage sag, making it the preferred Original New Spare Parts solution for engineers who cannot afford compromise. Its compatibility with ControlLogix, CompactLogix, and MicroLogix platforms means seamless integration into existing Industrial Automation architectures.

Whether you are upgrading an aging DCS cabinet or hardening a new SIS loop, the 1606-XLERED delivers the reliability, certifications, and global support infrastructure your operation demands. Contact our team today for a competitive quote and same-week dispatch.

Technical Specifications & Selection Guide

Specification Value
Part Number / SKU 1606-XLERED
Manufacturer Allen-Bradley (Rockwell Automation)
Module Type Redundancy / Diode-OR Module
Input Voltage Range 24-48V DC
Output Current (Continuous) 20A
Failover Transition Time <10ms (no voltage sag)
Operating Temperature -25°C to +70°C
Mounting Standard 35mm DIN Rail
Efficiency >95% typical
MTBF >500,000 hours @ 40°C
Certifications UL508, CE, RoHS, Class I Div 2
Compatible Power Supplies 1606-XLS series (e.g., 1606-XLS80E, 1606-XL480EP)
Condition 100% Original and Brand New

Selection Tip: Pair two identical-voltage 1606-XLS supplies with a single 1606-XLERED to achieve N+1 redundancy. For higher-current loads, parallel multiple modules per Rockwell Automation design guidelines.

Core Features & Technical Advantages

Automatic Diode-OR Load Sharing — Balances current draw across dual inputs; no manual intervention required during primary supply failure.
Sub-10ms Hot-Swap Failover — Transition occurs faster than most PLC watchdog timers, preventing nuisance faults in safety-critical Control Module loops.
Robust LED Diagnostics — Per-channel status indicators provide at-a-glance health monitoring without additional instrumentation.
Heavy-Duty Temperature Range — Rated -25°C to +70°C; suitable for outdoor enclosures and high-ambient machine rooms.
Precision Reverse-Current Protection — Diode architecture prevents backfeed from a failed supply into the healthy source.
Plug-and-Play Installation — Zero configuration required; mounts on standard 35mm DIN rail alongside existing 1606-XLS units.
Multi-Platform Compatibility — Verified with ControlLogix, CompactLogix, MicroLogix, and third-party 24V DC PLC System architectures.

Typical Application Scenarios

✅ Oil & Gas — Wellhead & Pipeline SCADA: Continuous telemetry and valve-control loops cannot tolerate power interruptions. The 1606-XLERED maintains 24V DC rail stability even during generator switchover events, protecting RTU and SIS instrumentation from data loss.

Power Generation — Substation Protection Panels: Relay protection systems demand five-nines availability. Deploying the 1606-XLERED in dual-feed configurations ensures protection logic remains active during scheduled UPS maintenance windows.

✅ Pharmaceutical — Batch Manufacturing (FDA 21 CFR Part 11): Unplanned shutdowns invalidate batch records and trigger costly revalidation. Redundant power via the 1606-XLERED safeguards HMI servers and historian nodes throughout multi-hour production cycles.

✅ Automotive — Body-Shop Robotics & Conveyor Control: High-cycle robotic cells require uninterrupted 24V DC for servo drives and safety light curtains. The module’s heavy-duty design withstands the vibration and EMI typical of stamping and welding environments.

✅ Water & Wastewater — SCADA & Pump Station Automation: Remote pump stations often rely on a single power feed. Adding the 1606-XLERED with a backup supply eliminates the most common cause of unplanned station outages in Industrial Automation networks.

Logistics & Professional Service

Shipping: Most in-stock orders ship within 2 business days via DHL Express, FedEx International Priority, or UPS Worldwide — your choice. Expedited same-day dispatch available upon request for urgent plant shutdowns.

1-Year Warranty: Every 1606-XLERED unit is covered by a 12-month warranty against manufacturing defects. Replacement or full refund processed within 5 business days of confirmed fault.

EOL & Legacy System Support: Rockwell Automation has transitioned many 1606-series items to limited availability. We maintain dedicated stock of Original New Spare Parts to support End-of-Life (EOL) legacy systems, ensuring your installed base remains operational without costly platform migrations.

Documentation: Factory test reports, Certificate of Conformance, and original Allen-Bradley datasheets provided upon request. Country-of-Origin certificates available for customs compliance.

FAQ — Frequently Asked Questions

Q1: What is the current price of the 1606-XLERED, and do you offer volume discounts?
A: Pricing varies with market availability and order quantity. For the most accurate and competitive quote on the 1606-XLERED — including tiered discounts for orders of 5 units or more — please contact sale@ninermas.com or use the inquiry form above. We respond to all RFQs within 4 business hours.

Q2: What is the lead time for the 1606-XLERED?
A: In-stock units ship within 1-2 business days. For larger quantities or special configurations, lead time is typically 3-7 business days. Emergency orders for plant shutdowns can often be expedited to same-day dispatch — contact us directly to confirm availability.

Q3: Can you provide an original Allen-Bradley datasheet and Certificate of Conformance for the 1606-XLERED?
A: Yes. We supply the official Rockwell Automation product datasheet (publication 1606-TD008) and a Certificate of Conformance confirming 100% Original and Brand New status. These documents are available upon order confirmation or pre-sale upon request.

Q4: Is the 1606-XLERED compatible with non-Allen-Bradley power supplies?
A: The module is optimized for the Allen-Bradley 1606-XLS series but will function with any 24-48V DC source meeting the input specifications. Consult the datasheet for derating guidelines when used with third-party supplies in mixed Industrial Automation environments.

Q5: How do I verify the module is genuine and not counterfeit?
A: All units sourced through NINERMAS COMPANY LIMITED are procured directly from authorized distribution channels. Each 1606-XLERED ships with original Allen-Bradley labeling, holographic authenticity seals, and traceable lot codes. We provide full traceability documentation upon request to satisfy your supplier qualification requirements.

Q6: Does the 1606-XLERED support hot-swap replacement without shutting down the PLC System?
A: Yes. The diode-OR design allows the failed supply — not the redundancy module itself — to be replaced while the system remains live. Always follow Rockwell Automation lockout/tagout procedures and consult the installation manual before performing live maintenance.


© 2026 NINERMAS COMPANY LIMITED. All rights reserved. Original Source: https://ninermas.com | Contact: sale@ninermas.com | +0086 187 5021 5667

Product Series

Other Legacy / Discontinued Modules

Country of Origin

US

Reviews

There are no reviews yet.

Be the first to review “Allen-Bradley 1606-XLERED Redundancy Module | Original Spare Parts”

Your email address will not be published. Required fields are marked

Catalog Continuation

More Allen-Bradley (Rockwell) modules in the catalog.

Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.

Open this lane

Catalog Continuation

Alternative parts within PLC & Industrial Automation Modules.

Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.

Open this lane

Industrial RFQ Support

Need a fast quote for a specific part number or system family?

Send your inquiry with brand, series, quantity, condition, and destination details. We will follow up on availability, lead time, and shipping options.

CallPhone MailEmail WAChat TopBack