Original Industrial Spare Part
Allen-Bradley 1738-AENT EtherNet/IP Adapter | POINT I/O Network Module
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKU1738-AENT
- CategoryPLC & Industrial Automation Modules
- BrandAllen-Bradley (Rockwell)
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: Allen-Bradley 1738-AENT EtherNet/IP Adapter | POINT I/O Network Module with SKU 1738-AENT.
Allen-Bradley 1738-AENT | Reliable EtherNet/IP Automation Component for POINT I/O
Field Application & Operational Analysis
From a Site Reliability Engineer’s perspective, the Allen-Bradley 1738-AENT stands as a cornerstone automation component in distributed I/O architectures where system availability is non-negotiable. The 1738-AENT bridges POINT I/O modules to EtherNet/IP networks with deterministic, sub-10ms scan cycles — directly reducing the risk of unplanned downtime in mission-critical manufacturing, process control, and material handling operations. Its native CIP (Common Industrial Protocol) stack eliminates protocol conversion overhead, ensuring seamless integration with ControlLogix, CompactLogix, and third-party EtherNet/IP scanners.
Engineered for operational excellence in harsh industrial environments, the 1738-AENT operates reliably across a 0°C to 60°C temperature range and is rated for DIN rail mounting within POINT I/O terminal base assemblies. Field technicians should verify backplane power draw during multi-module configurations and confirm firmware revision compatibility with the host controller prior to commissioning. Proper grounding of the DIN rail and shielded cabling on RJ45 ports are critical installation steps to suppress EMI-induced communication faults in high-noise environments.
As production lines increasingly depend on legacy POINT I/O infrastructure, maintaining a certified spare unit of the 1738-AENT is a fundamental element of any proactive maintenance strategy. End-of-life procurement cycles and global supply constraints make pre-stocking this module a cost-effective safeguard against extended production stoppages — a principle central to process optimization and operational excellence.
Key Operational Features
Dual Embedded Switch Ports (10/100 Mbps): Supports linear and Device Level Ring (DLR) topologies for built-in network redundancy and high availability.
Up to 63 POINT I/O Modules per Adapter: Scalable I/O expansion without additional hardware — ideal for large-scale system integration projects.
512 Bytes In / 512 Bytes Out: High-throughput data capacity sustains real-time process optimization across complex automation networks.
Electronic Keying: Prevents incorrect module substitution during maintenance, reducing human error in mission-critical environments.
Embedded Web Server: Browser-based diagnostics enable rapid fault isolation without dedicated software tools on the plant floor.
24V DC Backplane Power: Seamless integration with existing POINT I/O power supply infrastructure — no additional wiring required.
Maintenance & Performance Benchmarks
The 1738-AENT is architected to adapt across diverse industrial network scales — from compact standalone machine cells to enterprise-wide distributed control systems spanning multiple plant floors. In small-to-medium deployments (2-16 modules), the adapter delivers full I/O scan cycles well within 5ms, supporting high-speed packaging and assembly line applications. In large-scale configurations approaching the 63-module ceiling, network segmentation via DLR topology maintains deterministic communication even under peak load conditions.
For I/O modules in remote or environmentally demanding locations, the 1738-AENT’s DLR capability provides automatic network recovery in under 3ms following a single cable fault — a critical performance benchmark for continuous process industries such as oil & gas, chemical processing, and pharmaceutical manufacturing. Integration with Studio 5000 / RSLogix 5000 Add-On Profiles (AOPs) streamlines commissioning and enables predictive diagnostics through controller-level tag monitoring, a key enabler of modern I/O Modules-based predictive maintenance programs.
Comprehensive Data Sheet
| Attribute | Technical Data |
|---|---|
| Part Number | 1738-AENT |
| Manufacturer | Allen-Bradley / Rockwell Automation |
| Product Series | POINT I/O |
| Module Type | EtherNet/IP Communication Adapter |
| Network Protocol | EtherNet/IP (CIP) |
| Port Configuration | 2 — RJ45 (Dual Embedded Switch, 10/100 Mbps) |
| Topology Support | Linear, Star, Device Level Ring (DLR) |
| Max I/O Modules | 63 per adapter |
| Data Capacity | 512 bytes input / 512 bytes output |
| Power Supply | 24V DC via POINT I/O backplane |
| Operating Temperature | 0°C to 60°C (32°F to 140°F) |
| Storage Temperature | -40°C to 85°C |
| Mounting | DIN Rail (POINT I/O Terminal Base) |
| Certifications | UL, CE, cUL, ATEX (Zone 2 with ArmorPoint) |
| Compatible Controllers | ControlLogix 1756, CompactLogix 1769, FlexLogix 1794, SoftLogix, DriveLogix, 3rd-party EtherNet/IP scanners |
| Configuration Software | Studio 5000 / RSLogix 5000 with AOP |
| Condition | New & Original Factory Sealed |
| Warranty | 1 Year |
Professional Logistics & Sourcing Excellence
Every 1738-AENT unit dispatched from our inventory is sourced directly from authorized distribution channels and ships in original factory packaging — complete with manufacturer documentation, firmware revision labels, and tamper-evident seals. This guarantees authenticity and protects your warranty entitlement from day one.
Same-Day Dispatch: In-stock units confirmed before 2:00 PM (local time) qualify for same-day shipment via DHL Express, FedEx International Priority, or UPS Worldwide Expedited.
Global Supply for EOL & Legacy Modules: We maintain strategic buffer stock of discontinued and long-lead-time automation components, including the 1738-AENT, to support facilities operating legacy POINT I/O infrastructure beyond standard product lifecycle.
Worldwide Express Logistics: Delivery coverage spans North America, Europe, Southeast Asia, the Middle East, and beyond — with full customs documentation and export compliance support.
Secure Packaging: Anti-static shielding, foam-lined cartons, and climate-controlled storage protect sensitive I/O modules throughout the entire logistics chain.
Engineering Support & FAQ
Q1: What are the step-by-step installation requirements for the 1738-AENT?
Mount the adapter onto a compatible POINT I/O terminal base (1738-TB3 or 1738-TB3S) on a grounded DIN rail. Connect both RJ45 ports per your network topology (linear or DLR). Apply 24V DC backplane power, then configure the IP address via BOOTP/DHCP or the module’s rotary switches. Import the AOP into Studio 5000 and map I/O tags to your controller program. Verify LED status: steady green on NET and MOD indicators confirms successful commissioning.
Q2: Which firmware versions are compatible with current ControlLogix controllers?
Firmware revision 4.x and above is recommended for use with ControlLogix L7x/L8x series controllers running Logix firmware v30 or later. For CompactLogix L3x platforms, revision 3.x is the minimum supported version. Always cross-reference the Rockwell Automation Product Compatibility and Download Center (PCDC) for the latest compatibility matrix before upgrading.
Q3: Does the 1738-AENT support Device Level Ring (DLR) for network redundancy?
Yes. Both embedded switch ports natively support DLR topology, enabling automatic ring recovery in under 3ms following a single-point cable or switch failure — a critical capability for high-availability process lines where network interruption is unacceptable.
Q4: How does the warranty claim process work?
All units carry a 1-year warranty from the date of invoice. To initiate a claim, contact our technical support team at sale@ninermas.com with your order number, unit serial number, and a description of the fault symptom. We will arrange advance replacement or repair within 5 business days, with return freight covered for confirmed manufacturing defects.
Q5: Can this adapter communicate with non-Rockwell EtherNet/IP controllers?
Yes. The 1738-AENT implements the open CIP (Common Industrial Protocol) standard, making it compatible with any EtherNet/IP Class 1 scanner — including Siemens, Omron, Mitsubishi, and Schneider Electric platforms — provided the third-party controller supports explicit or implicit CIP messaging.
Q6: What is the maximum cable length between the adapter and network switch?
Per IEEE 802.3 standards, maximum Cat5e/Cat6 cable run length is 100 meters (328 ft) per segment. For longer distances, use managed industrial switches with fiber uplinks. Shielded cable (STP) is strongly recommended in environments with significant electromagnetic interference from VFDs, welding equipment, or high-voltage bus bars.
| Product Series | ControlLogix 1756 |
|---|---|
| Country of Origin | US |
Catalog Continuation
More Allen-Bradley (Rockwell) modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
Catalog Continuation
Alternative parts within PLC & Industrial Automation Modules.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
SKU: TRY/PRG/4-20MA/10-30DC
MOORE TRY/PRG/4-20MA/10-30DC Service-Ready Spare Part
SKU: 5085-404901-11 12INCH 2910-202413-12 404200XRMPD2H14 7-249717
TEL 5085-404901-11 Service-Ready Spare Part for Industrial Maintenance
SKU: DIP011 05-058-011
Reviews
There are no reviews yet.