Original Industrial Spare Part
GE IC695PNC001-AK Retrofit-Compatible PROFINET Controller
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKUIC695PNC001-AK
- CategoryPLC & Industrial Automation Modules
- BrandGE Fanuc
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: GE IC695PNC001-AK Retrofit-Compatible PROFINET Controller with SKU IC695PNC001-AK.
GE IC695PNC001-AK Retrofit-Compatible PROFINET Controller for Legacy System Modernization
The GE IC695PNC001-AK is a ruggedized PROFINET Controller Module designed for the GE PACSystems RX3i platform. As legacy automation infrastructure ages and original spare parts become increasingly scarce, the IC695PNC001-AK serves as a critical retrofit-compatible replacement for plants operating aging control architectures. Whether you are managing a brownfield upgrade, replacing a discontinued PROFINET master, or extending the operational life of an existing RX3i control cabinet, this module provides a direct-fit solution with minimal re-engineering overhead.
Engineered for harsh industrial environments, the IC695PNC001-AK carries a ruggedized designation (AK suffix), indicating enhanced tolerance for temperature extremes, vibration, and humidity — conditions commonly encountered in heavy manufacturing, oil & gas processing, and utility substations. Its compatibility with the standard RX3i Universal Backplane (IC695CHS016, IC695CHS012, IC695CHS007) means that existing cabinet layouts and backplane wiring can be preserved during the replacement process, significantly reducing installation time and downtime exposure.
Upgrade Compatibility Table
| Parameter | IC695PNC001-AK | Retrofit Notes |
|---|---|---|
| Platform Compatibility | GE PACSystems RX3i | Direct slot replacement on RX3i Universal Backplane |
| Communication Protocol | PROFINET IO (Controller) | Compatible with PROFINET IO Device networks; verify GSD file versions |
| Backplane Interface | RX3i High-Speed Backplane Bus | Supports IC695CHS016, IC695CHS012, IC695CHS007 chassis |
| Power Requirement | Supplied via backplane (IC695PSA040 / IC695PSD040) | Verify power supply capacity before installation; AK variant may draw marginally higher current |
| Module Addressing | Rack/Slot-based addressing in PAC Machine Edition | Confirm slot assignment matches existing program logic; re-download may be required |
| HMI Compatibility | Compatible with iFIX, CIMPLICITY, and third-party OPC-DA/UA clients | Verify PROFINET device tags are correctly mapped in HMI project after module swap |
| Environmental Rating | Ruggedized (AK) — extended temperature & vibration tolerance | Suitable for harsh-environment cabinets without additional enclosure modification |
| Firmware / Software | PAC Machine Edition (PME) 9.x and above | Confirm PME version compatibility; firmware update may be required post-installation |
| Installation Space | Single-slot RX3i module | No additional rack space required vs. standard IC695PNC001 |
| Warranty | 12-Month Warranty | Covered from date of shipment; includes functional testing pre-dispatch |
Retrofit Planning for Existing Automation Systems
Successful integration of the IC695PNC001-AK into a running production environment requires systematic pre-installation planning. The first step is a thorough audit of the existing RX3i rack configuration. Plants typically run a combination of modules including the IC695CPU315 or IC695CPU320 as the main controller, alongside analog input modules such as the IC695ALG608, discrete I/O modules like the IC694MDL754, and communication modules including the IC695ETM001 Ethernet interface. Each of these modules occupies a defined slot address, and the PROFINET controller’s slot position must be confirmed against the existing PAC Machine Edition hardware configuration tree before any physical swap is attempted.
Power budget verification is a non-negotiable step. The RX3i backplane power supply — commonly the IC695PSA040 (40W AC) or IC695PSD040 (40W DC) — must have sufficient headroom to support the IC695PNC001-AK alongside all co-resident modules. Engineers should calculate the total backplane current draw and compare it against the power supply’s rated output, accounting for any additional I/O expansion racks connected via the IC695RMX128 Remote I/O Scanner or similar expansion modules.
Terminal wiring on the PROFINET network side requires attention to port configuration. The IC695PNC001-AK provides dual RJ45 PROFINET ports supporting media redundancy (MRP). If the legacy system used a single-port PROFINET master, the wiring topology may need to be updated to take advantage of ring redundancy, or alternatively, one port can be left unused for a linear topology. PROFINET device GSD files for all connected IO devices — including remote I/O stations, variable frequency drives, and safety modules — must be imported into the PAC Machine Edition project and verified against the physical network layout.
For plants migrating from older GE Series 90-30 or Series 90-70 control platforms, the IC695PNC001-AK represents a significant protocol migration step. Legacy DeviceNet or Genius Bus networks must be bridged or replaced with PROFINET-compatible equivalents. In such scenarios, a IC695PBM300 PROFIBUS Master module or a dedicated protocol gateway may be required to maintain connectivity with legacy field devices during the transition period, allowing a phased migration rather than a full cutover.
HMI screen updates are frequently overlooked during PROFINET controller replacements. If the plant uses CIMPLICITY or iFIX SCADA systems, the OPC server tag database must be validated after the module swap to ensure all PROFINET device data points are correctly mapped. Any changes to the PROFINET device network topology — such as added IO devices or modified device names — will require corresponding updates in the HMI project to prevent alarm suppression or data loss on operator screens.
Downtime Control During System Migration
Minimizing production downtime during a PROFINET controller replacement is achievable with disciplined pre-staging and a structured cutover plan. The recommended approach is to pre-configure the replacement IC695PNC001-AK offline using PAC Machine Edition before the maintenance window begins. This includes loading the existing program backup, verifying the hardware configuration matches the physical rack layout, and performing a simulated I/O scan to confirm all PROFINET device connections are correctly defined.
During the physical swap, the original IC695PNC001 (or predecessor module) should be removed only after the CPU has been placed in STOP mode and all field outputs have been confirmed safe. The replacement IC695PNC001-AK should be inserted into the same backplane slot, and the system powered up in a controlled sequence — power supply first, then CPU, then communication modules. This sequence protects the backplane bus from transient voltage spikes and allows the CPU to initialize its I/O table before the PROFINET controller begins scanning the network.
Post-installation, the engineer should perform a full PROFINET network diagnostic using the integrated diagnostic tools in PAC Machine Edition or a standalone PROFINET analyzer. Key checks include verifying that all IO devices have established communication, confirming that the update cycle times are within specification, and validating that the program logic is executing correctly against live field signals. If the plant uses a IC695CMM004 serial communications module for legacy device connectivity, its configuration should also be verified to ensure no address conflicts have been introduced during the module swap.
Throughout the migration, maintaining a detailed change log — including module serial numbers, firmware versions, slot assignments, and network topology diagrams — provides an essential audit trail for future maintenance and supports warranty claim processing if required within the 12-month coverage period.
Retrofit Support FAQ
Q1: Is the IC695PNC001-AK a direct drop-in replacement for the standard IC695PNC001?
Yes. The AK suffix denotes the ruggedized variant with enhanced environmental ratings. It occupies the same single backplane slot, uses the same PAC Machine Edition hardware configuration entry, and is fully compatible with existing PROFINET IO device networks configured for the standard IC695PNC001. No program changes are required for a like-for-like slot replacement, though a firmware update may be recommended depending on the installed PME version.
Q2: What pre-shipment testing is performed on the IC695PNC001-AK?
Each unit undergoes functional testing prior to dispatch, including power-on verification, backplane communication check, and PROFINET port connectivity validation. Test records are available upon request. All units are shipped with a 12-month warranty covering manufacturing defects and functional failures under normal operating conditions.
Q3: Can this module be used in a mixed RX3i rack alongside Series 90-30 I/O modules via an adapter?
The IC695PNC001-AK is designed for the RX3i Universal Backplane and communicates via the RX3i high-speed backplane bus. It does not natively interface with Series 90-30 I/O modules. However, the RX3i platform supports the IC694BEM331 Bus Expansion Module, which allows Series 90-30 I/O racks to be connected as remote expansion racks, preserving legacy I/O investments during a phased migration.
Q4: What is the lead time and stock availability for the IC695PNC001-AK?
NINERMAS maintains inventory of the IC695PNC001-AK to support urgent replacement requirements. Standard lead time for in-stock units is 3–7 business days for international shipments. For large-quantity orders or long-term supply agreements covering multi-year maintenance contracts, please contact our sales team directly to discuss dedicated stock allocation and pricing.
| Product Series | PACSystems |
|---|---|
| Country of Origin | US |
Catalog Continuation
More GE Fanuc modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
SKU: HE693THM888K-13
GE Fanuc HE693THM888K-13 Retrofit Thermocouple Input Module
SKU: IC694PSM001-BB
GE Fanuc IC694PSM001-BB Safety-Reliable Power Supply Module
Catalog Continuation
Alternative parts within PLC & Industrial Automation Modules.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
SKU: 4-AXIS BXI4/2-01-B
BERKELEY BXI4/2-01-B Retrofit-Compatible Motion Controller
SKU: METEOR/RGB PCI 571-03
Matrox METEOR/RGB PCI 571-03 Service-Ready Spare Part