FUJI NR1TY-16T05DT Service-Ready Spare Part for Industrial Maintenance

The FUJI NR1TY-16T05DT is an original thermal overload relay from FUJI Electric’s NR1TY series, engineered for reliable motor protection in demanding industrial environments. Designed to integrate seamlessly with FUJI SC-series magnetic contactors and motor control centers, this component provides precise overload detection and trip response to safeguard motors, drives, and downstream electrical circuits from sustained overcurrent conditions. For maintenance engineers managing aging control panels, production line restarts, or annual overhaul programs, having a verified, service-ready NR1TY-16T05DT in your spare parts inventory is a critical element of any proactive maintenance strategy.

At NINERMAS, every NR1TY-16T05DT unit is pre-shipment tested, documented, and dispatched under a 12-month warranty, ensuring that your replacement component performs to original FUJI Electric specifications from the moment it is installed on site.

Spare Maintenance Table

Parameter Specification
Part Number NR1TY-16T05DT
Brand FUJI Electric
Series NR1TY
Product Type Thermal Overload Relay
Setting Current Range Approx. 10–16 A (T05DT range)
Trip Class Class 10 (standard motor protection)
Reset Mode Manual / Auto selectable
Auxiliary Contacts 1NO + 1NC
Compatible Contactor FUJI SC-N1 / SC-N2 series
Mounting Direct mount to FUJI SC-series contactor
Ambient Temperature -20°C to +60°C
Protection Degree IP20 (panel-mounted)
Origin Japan
Warranty 12 Months (NINERMAS)
Pre-shipment Test Yes — functional and insulation verified
Long-term Supply Available via NINERMAS stock commitment program

Maintenance Planning for Continuous Operation

When replacing the NR1TY-16T05DT during a scheduled overhaul or emergency breakdown, maintenance engineers should treat the intervention as an opportunity to audit the entire motor starter circuit. The NR1TY-16T05DT operates in direct combination with a FUJI SC-N1 or SC-N2 magnetic contactor — inspect the contactor’s main contacts and coil for wear, pitting, or coil resistance drift before reinstating the circuit. If the contactor shows signs of contact erosion, replace it alongside the overload relay to prevent nuisance tripping after restart.

Upstream of the starter assembly, verify the condition of the motor circuit breaker or fuse disconnect (such as a FUJI BW-series MCCB or equivalent) to confirm that short-circuit protection ratings remain coordinated with the new overload setting. Check the control transformer supplying the coil circuit — a sagging secondary voltage is a common cause of contactor chatter and premature overload relay fatigue.

On the I/O side, inspect the PLC digital output module driving the contactor coil command. Intermittent DO channel faults can cause repeated motor starts that stress the overload relay bimetal element. If the system uses a FUJI MICREX-SX or MICREX-F series PLC, confirm that the relevant output module (such as an NP1X16 or NP1Y16 I/O card) is free of channel faults before closing the circuit.

For motor circuits feeding pumps, fans, or compressors in process plants, also inspect the phase sequence relay and voltage monitoring relay installed in the same panel section. Phase loss or voltage unbalance is a leading cause of thermal overload relay trips and motor winding damage — a FUJI EW-series or equivalent voltage relay provides an additional protection layer that complements the NR1TY-16T05DT’s thermal trip function.

Where the motor is controlled via a variable frequency drive (VFD), confirm that the overload relay is correctly configured for inverter-duty operation or bypassed in accordance with the drive manufacturer’s wiring diagram. In bypass-mode starters, the NR1TY-16T05DT remains active during direct-on-line starting and must be set to the motor’s full-load current nameplate value.

Terminal block condition is frequently overlooked during overload relay replacement. Inspect the Phoenix Contact or Weidmüller-type terminal strips adjacent to the starter for loose screws, discoloration from heat, or insulation cracking. Retorque all power and control terminals to the manufacturer’s specification. For panels operating in high-vibration environments, consider replacing standard screw terminals with spring-clamp variants to prevent connection loosening over time.

Finally, update your CMMS (Computerized Maintenance Management System) with the replacement date, new serial number, and current setting value of the NR1TY-16T05DT. Establish a preventive maintenance interval — typically 3 years or 10,000 operating hours — for the next inspection of the thermal overload relay and associated motor starter components. Maintaining a minimum of one spare NR1TY-16T05DT per motor starter group in your on-site inventory is recommended to support rapid recovery from unplanned outages.

Site Replacement Workflow

Step 1 — Isolation & Lockout: De-energize the motor circuit at the upstream MCCB or fuse disconnect. Apply LOTO (Lockout/Tagout) to the isolator. Verify absence of voltage at the contactor line terminals using a calibrated voltage tester.

Step 2 — Document Current Settings: Record the existing overload relay current setting dial position and reset mode before removal. Photograph the wiring layout for reference during reinstallation.

Step 3 — Remove the Faulty Unit: Disconnect the auxiliary contact wiring (typically 95/96 NC and 97/98 NO terminals). Unclip the NR1TY relay from the SC-series contactor by releasing the mechanical latch. Remove the power wiring from the T1/T2/T3 output terminals.

Step 4 — Install the NR1TY-16T05DT Replacement: Clip the new NR1TY-16T05DT directly onto the FUJI SC-N1/N2 contactor frame. Reconnect T1/T2/T3 power terminals and auxiliary control wiring. Set the current dial to the motor’s nameplate full-load ampere (FLA) value. Confirm reset mode selection matches the application requirement.

Step 5 — Functional Verification: Re-energize the circuit and perform a no-load motor start. Monitor current draw on all three phases using a clamp meter. Confirm the overload relay does not trip under normal running conditions. Log the commissioning data in the site maintenance record.

Step 6 — Compatibility Confirmation: The NR1TY-16T05DT is a direct replacement for earlier NR1TY-series units with equivalent current range designations. Cross-reference the T05DT suffix against the FUJI Electric NR1TY selection table to confirm frame compatibility if substituting across sub-series variants.

Spare Parts Support FAQ

Q1: What is the warranty coverage for the NR1TY-16T05DT supplied by NINERMAS?
All NR1TY-16T05DT units supplied by NINERMAS carry a 12-month warranty from the date of shipment. Each unit undergoes pre-shipment functional and insulation testing. In the event of a warranty claim, NINERMAS provides replacement or full refund subject to inspection of the returned component.

Q2: Can the NR1TY-16T05DT be used as a direct drop-in replacement for older NR1TY variants?
Yes, within the same current range bracket. The NR1TY series maintains consistent mechanical mounting dimensions across the product family for direct contactor attachment to FUJI SC-N1 and SC-N2 frames. Always verify the current setting suffix (T05DT = approximately 10–16 A range) matches your motor’s FLA before installation. Contact NINERMAS technical support if cross-series compatibility confirmation is required.

Q3: Does NINERMAS offer long-term supply commitments for the NR1TY-16T05DT?
Yes. NINERMAS operates a stock commitment program for long lifecycle industrial components, including FUJI NR1TY-series overload relays. Customers managing aging motor control systems or multi-site maintenance programs can arrange forward stock reservations and scheduled delivery agreements to eliminate procurement lead time risk.

Q4: How should the NR1TY-16T05DT be stored as a spare part?
Store in original packaging or an anti-static bag in a dry, temperature-controlled environment (recommended: 5°C to 40°C, relative humidity below 75% non-condensing). Avoid storage near strong magnetic fields or corrosive atmospheres. Inspect the bimetal element and contact surfaces annually if the unit remains in long-term storage. NINERMAS recommends rotating spare stock every 5 years to maintain optimal performance readiness.

Product Series

Other series

Catalog Continuation

More Fuji Electric modules in the catalog.

Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.

Open this lane

Catalog Continuation

Alternative parts within PLC & Industrial Automation Modules.