Original Industrial Spare Part

ABB QINT-781 3AXD5000019758 Service-Ready Spare Part

Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.

SKU: QINT-781 3AXD5000019758 PLC & Industrial Automation Modules ABB

RFQ Ready

Pricing by RFQ

How Buyers Usually Use This Page

  • Confirm the exact part number and platform family before sending the quote request.
  • Use direct email when quantity, condition, and destination are already defined internally.
  • Switch to the broader brand or category archive when you need alternates nearby.

Series Navigation

Move through the most common platform families behind this part.

ABB QINT-781 3AXD5000019758 Service-Ready Spare Part for Industrial Maintenance

The ABB QINT-781 (3AXD5000019758) is a critical power supply and control interface module designed for use within ABB’s ACS880 and ACS580 variable frequency drive (VFD) series. As industrial automation systems age and OEM support windows narrow, maintaining a reliable inventory of service-ready spare parts like the QINT-781 becomes essential for minimizing unplanned downtime and protecting production continuity. NINERMAS supplies this module as an original, tested, and warranty-backed replacement component — ready for immediate deployment in your maintenance workflow.

Whether you are a maintenance engineer conducting a scheduled annual overhaul, responding to an emergency drive fault, or a procurement engineer building a strategic spare parts buffer for a multi-line facility, the QINT-781 3AXD5000019758 is a high-priority item to stock. Its role in power conditioning, internal bus communication, and drive control logic makes it a single point of failure that, if left unaddressed, can halt an entire production line within seconds of a fault event.

Spare Maintenance Table

Parameter Specification / Details
Part Number QINT-781
ABB Reference Code 3AXD5000019758
Compatible Drive Series ABB ACS880, ACS580
Module Function Internal Power Supply / Control Interface Module
Rated Input Voltage 24 VDC (internal bus, drive-supplied)
Operating Temperature -10°C to +55°C (storage: -40°C to +70°C)
Mounting Type Direct backplane / drive frame slot installation
Communication Interface Internal drive bus (DDCS / FCAN compatible environment)
Compatibility Confirmation ACS880-01, ACS880-07, ACS880-17, ACS580-01 frame sizes
Condition New / Service-Ready Original
Origin Finland (ABB Drives manufacturing)
Warranty 12 Months from date of shipment
Pre-shipment Testing Function-verified before dispatch
Lead Time In-stock: ships within 1–3 business days
Long-term Supply Supported — contact NINERMAS for blanket order pricing

Maintenance Planning for Continuous Operation

When replacing the QINT-781 3AXD5000019758 in an ACS880 or ACS580 drive cabinet, experienced maintenance engineers know that the module rarely fails in isolation. A thorough site inspection and preventive replacement of adjacent components is strongly recommended to avoid repeat call-outs and secondary failures.

Begin by inspecting the APOW-01 auxiliary power supply board, which works in tandem with the QINT-781 to regulate internal 24 VDC logic power. A degraded APOW-01 can cause intermittent QINT-781 faults that are misdiagnosed as module failure. Similarly, the AINT-02 or AINT-14 inverter control board should be checked for firmware version compatibility and any signs of capacitor aging or thermal stress.

On the I/O side, verify the condition of the AIMA-01 I/O extension module and any FIO-01 or FIO-11 fieldbus I/O adapter installed in the drive’s option slots. Loose terminal connections on the X1 and X2 control terminal blocks are a common source of intermittent faults that can be mistakenly attributed to the QINT-781 itself. Inspect all 24 VDC wiring harnesses and replace any connectors showing signs of oxidation or heat discoloration.

For drives integrated into a PROFIBUS or PROFINET network, inspect the FPBA-01 PROFIBUS adapter or FENA-21 Ethernet/IP adapter for firmware currency and physical connector integrity. Communication faults at the fieldbus layer can cascade into drive control errors that appear as power supply module alarms. If the drive is part of a multi-drive system using the RDCU-02C drive control unit, ensure the DDCS fiber optic links are clean and undamaged.

Do not overlook the du/dt output filter and EMC line filter on the input side — degraded filter capacitors can introduce voltage spikes that stress internal modules including the QINT-781. For older ACS880 installations, proactively replacing the DC bus capacitor bank during the same maintenance window is a cost-effective way to extend drive service life by 5–8 years. Finally, confirm that the brake chopper module (BAMU-01) and any associated braking resistors are within specification, as regenerative energy mismanagement can cause internal bus overvoltage events.

Site Replacement Workflow

Replacing the QINT-781 3AXD5000019758 on-site is a structured process that, when followed correctly, can restore drive operation within 30–60 minutes of module arrival at the panel. Follow this workflow to minimize downtime and ensure system compatibility:

Step 1 — Isolation & Lockout/Tagout: De-energize the ACS880/ACS580 drive and apply LOTO procedures. Allow a minimum of 5 minutes for DC bus capacitors to discharge before opening the drive cabinet. Verify bus voltage with a calibrated multimeter before touching any internal components.

Step 2 — Fault Log Review: Before removing the old module, connect a laptop running Drive Composer Pro or DriveWindow Light and download the full fault history. Document the last 10 fault codes — this data is invaluable for root cause analysis and warranty claims.

Step 3 — Module Removal: Carefully disconnect all ribbon cables and bus connectors from the QINT-781. Note the orientation and routing of each cable before removal. Use an ESD wrist strap throughout the process.

Step 4 — New Module Installation: Install the new QINT-781 3AXD5000019758 into the drive frame slot. Reconnect all cables in reverse order of removal. Verify that all connectors are fully seated and latched.

Step 5 — Parameter Restore & Commissioning: Restore drive parameters from a previously saved backup file. If no backup exists, re-enter critical parameters manually: motor nameplate data, control mode, speed references, and I/O assignments. Perform a no-load test run before reconnecting the mechanical load.

Step 6 — System Handover: Document the replacement in the site maintenance log, update the spare parts inventory, and reorder a replacement QINT-781 to restore your buffer stock. NINERMAS recommends maintaining a minimum of one spare per 5 installed drives of the same series.

Spare Parts Support FAQ

Q1: Is the QINT-781 3AXD5000019758 compatible with both ACS880 and ACS580 drive series?
Yes. The QINT-781 with reference code 3AXD5000019758 is designed for use across multiple ABB drive platforms including the ACS880 and ACS580 series. However, compatibility depends on the specific drive frame size and hardware revision. NINERMAS recommends providing your drive’s full nameplate data (type code, serial number, and firmware version) when placing an order so our technical team can confirm fitment before shipment.

Q2: What pre-shipment testing does NINERMAS perform on the QINT-781?
Every QINT-781 unit shipped by NINERMAS undergoes a function verification test on a compatible drive test bench before dispatch. This includes power-on self-test, internal bus communication check, and visual inspection for physical damage. A test report is available upon request. All units are shipped in anti-static packaging with a 12-month warranty from the date of shipment.

Q3: Can NINERMAS support long-term or blanket purchase orders for the QINT-781?
Yes. NINERMAS specializes in long-term spare parts supply for industrial automation components, including discontinued and hard-to-source ABB modules. We support blanket purchase orders, consignment stock arrangements, and annual supply contracts for maintenance teams managing large fleets of ACS880 or ACS580 drives. Contact our sales team at sale@ninermas.com to discuss volume pricing and lead time commitments.

Q4: What should I do if the replacement QINT-781 does not resolve the drive fault?
If installing a new QINT-781 does not clear the fault, the root cause is likely in an adjacent component rather than the module itself. Common secondary causes include a failed APOW-01 auxiliary power board, corrupted drive firmware, a damaged DDCS fiber link, or a wiring fault on the 24 VDC control circuit. NINERMAS’s technical support team can assist with fault code interpretation and component-level diagnosis. Reach us at sale@ninermas.com or +0086 187 5021 5667.

Product Series

ACS880

Country of Origin

SE

Catalog Continuation

More ABB modules in the catalog.

Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.

Open this lane

Catalog Continuation

Alternative parts within PLC & Industrial Automation Modules.

Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.

Open this lane

Industrial RFQ Support

Need a fast quote for a specific part number or system family?

Send your inquiry with brand, series, quantity, condition, and destination details. We will follow up on availability, lead time, and shipping options.

CallPhone MailEmail WAChat TopBack