Original Industrial Spare Part
Veriflo 0050-36242 Retrofit-Compatible Valve for Legacy Systems
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKU0050-36242 944AOPLPNC3PWTS4275 615-00325-000 0200-01271
- CategoryPLC & Industrial Automation Modules
- BrandVeriflo
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: Veriflo 0050-36242 Retrofit-Compatible Valve for Legacy Systems with SKU 0050-36242 944AOPLPNC3PWTS4275 615-00325-000 0200-01271.
Veriflo 0050-36242 Retrofit-Compatible Valve for Legacy Systems
The Veriflo 0050-36242 — cross-referenced as 944AOPLPNC3PWTS4275, 615-00325-000, and 0200-01271 — is a precision gas delivery valve engineered for semiconductor process equipment. Designed to serve as a direct retrofit-compatible replacement within legacy gas panel assemblies, this component supports continuity of operation in aging fab environments where original equipment manufacturers have discontinued active production of matching assemblies. For maintenance engineers and procurement specialists managing long-cycle semiconductor tools, securing a verified original spare like the 0050-36242 is a critical step in sustaining uptime and process integrity.
Veriflo, a Parker Hannifin division, has long been the standard supplier for high-purity gas delivery components in semiconductor manufacturing. The 944A series valves — including the 0050-36242 — are widely deployed across CVD, ALD, etch, and diffusion tool platforms. As these tools age beyond their original support windows, sourcing compatible replacement valves becomes increasingly difficult through standard distribution channels. NINERMAS maintains verified inventory of the 0050-36242 to support retrofit projects, emergency replacements, and planned maintenance cycles.
Upgrade Compatibility Table
| Parameter | Specification / Detail |
|---|---|
| Part Number | 0050-36242 |
| Cross Reference | 944AOPLPNC3PWTS4275 / 615-00325-000 / 0200-01271 |
| Brand / Manufacturer | Veriflo (Parker Hannifin) |
| Series | 944A / 615 Series |
| Component Type | High-Purity Gas Delivery Valve |
| Application | Semiconductor CVD, ALD, Etch, Diffusion Systems |
| Interface Compatibility | VCR face-seal fittings; standard gas panel manifold mounting |
| Actuation | Pneumatic (normally closed) |
| Body Material | 316L SS electropolished |
| Retrofit Fit | Direct drop-in for 944A series gas panel positions |
| Installation Note | Verify actuator port orientation and pneumatic supply pressure (typically 60–80 psi) |
| Commissioning Check | Confirm VCR gasket condition; leak-check at full process pressure before restart |
| Warranty | 12-Month Warranty from shipment date |
| Pre-Shipment Testing | Functional and leak integrity tested before dispatch |
Retrofit Planning for Existing Automation Systems
A successful retrofit of the Veriflo 0050-36242 into a legacy gas panel requires a structured review of the surrounding system components. Maintenance engineers should begin by auditing the pneumatic actuator supply lines — confirming that the existing solenoid valve bank (commonly Veriflo 944B or equivalent Parker solenoid assemblies) delivers consistent pilot pressure to the replacement valve. Pressure regulators upstream of the gas panel, such as the Veriflo 3900 series or Parker Watts regulators, should be inspected for diaphragm wear and set-point drift before the retrofit is finalized.
Within the gas panel itself, adjacent components that frequently require simultaneous attention include VCR gaskets (typically 316L SS or nickel, sized to the 1/4-inch face-seal standard), manual isolation valves at the panel inlet, and mass flow controller (MFC) inlet fittings. If the tool uses a Veriflo 615 series manifold block, confirm that the manifold body threads and port alignment are undamaged before installing the 0050-36242. Damaged manifold ports are a common source of post-retrofit leaks that extend downtime unnecessarily.
For tools integrated with process control systems — such as Applied Materials Centura or Lam Research platforms — the valve’s open/close status is typically monitored through a discrete I/O module on the tool’s PLC or embedded controller. Verify that the I/O channel assignment and signal polarity match the replacement valve’s actuator feedback (if equipped). In systems using a Brooks or MKS gas control module, confirm that the valve command sequence in the recipe software aligns with the physical valve position after replacement. Pneumatic tubing connections (typically 1/4-inch OD Swagelok or equivalent compression fittings) should be inspected for cracking or work-hardening before reconnection.
Additional components to review during the retrofit window include the gas panel purge valve assembly, the vent valve downstream of the process valve, and any inline particle filters or sintered metal frits protecting the MFC inlet. If the tool has been in service for more than five years, replacing the pneumatic tubing bundle serving the 944A valve bank as a preventive measure is strongly recommended. This reduces the risk of a secondary pneumatic failure shortly after the primary valve retrofit is completed.
Downtime Control During System Migration
Minimizing downtime during a Veriflo 0050-36242 replacement requires pre-staging all materials before the tool is taken offline. Confirm that the replacement valve, VCR gaskets, pneumatic fittings, and any required tools (torque wrench, VCR nut driver) are on-site and verified before scheduling the maintenance window. A typical valve swap on a 944A series gas panel can be completed in two to four hours by an experienced field engineer, provided no manifold damage or pneumatic line rework is required.
Before removing the legacy valve, document the current valve position (open/closed) and the pneumatic supply state. Purge the gas line to atmospheric pressure and verify with a portable gas detector before breaking any VCR connections. After installing the 0050-36242, perform a helium leak check at the VCR joints before restoring process gas flow. This step is non-negotiable in high-purity applications — even a minor leak at a VCR joint can contaminate the process gas stream and cause wafer-level defects.
Once the valve is installed and leak-checked, restore pneumatic supply and cycle the valve through its full open/close range using the tool’s manual diagnostic mode. Confirm that the I/O feedback signal (if present) correctly reflects valve state before returning the tool to automated recipe control. Log the replacement in the tool’s maintenance record, including the new part number, installation date, and technician ID, to support future warranty claims and audit readiness.
Retrofit Support FAQ
Q1: Is the Veriflo 0050-36242 a direct replacement for the 944AOPLPNC3PWTS4275 and 615-00325-000?
Yes. The 0050-36242 is cross-referenced to 944AOPLPNC3PWTS4275, 615-00325-000, and 0200-01271. These part numbers represent the same valve assembly sourced through different procurement channels or tool OEM part numbering systems. Confirm the VCR port size and actuator orientation match your specific gas panel layout before installation.
Q2: What pre-shipment testing is performed on the 0050-36242?
Each unit undergoes functional actuation testing and leak integrity verification before dispatch. Test records are available upon request. The valve is shipped in a sealed, cleanroom-compatible package to maintain surface cleanliness for high-purity gas service.
Q3: What is the warranty coverage and how is it claimed?
NINERMAS provides a 12-month warranty from the shipment date covering manufacturing defects and functional failures under normal operating conditions. To initiate a warranty claim, contact sale@ninermas.com with the order reference, installation date, and a description of the observed failure. Replacement or repair will be coordinated promptly.
Q4: Can NINERMAS support long-term supply commitments for the 0050-36242?
Yes. NINERMAS maintains reserved inventory programs for high-demand legacy components including the Veriflo 944A series. Long-term supply agreements with defined lead times and pricing are available for customers managing multi-tool fleets or annual maintenance contracts. Contact our procurement team to discuss volume commitments and stocking arrangements.
| Product Series | Legacy |
|---|
Catalog Continuation
Alternative parts within PLC & Industrial Automation Modules.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
SKU: 4-AXIS BXI4/2-01-B
BERKELEY BXI4/2-01-B Retrofit-Compatible Motion Controller
SKU: METEOR/RGB PCI 571-03
Matrox METEOR/RGB PCI 571-03 Service-Ready Spare Part