The Siemens MICROMASTER 440 (6SE6440-2UD17-5AA1) is a compact, high-performance variable frequency drive designed for precise motor speed control in industrial applications. Through advanced vector control technology and programmable logic, it delivers smooth acceleration, deceleration, and energy-efficient operation for AC motors ranging from 0.12kW to 250kW.
Ideal for applications requiring variable speed control—including HVAC systems, pumps, fans, conveyors, and material handling equipment—this drive helps solve common challenges such as high energy consumption, mechanical stress from direct-on-line starting, limited process control, and excessive motor wear. It is particularly suited for manufacturing plants, building automation, water treatment facilities, and industrial process control environments.
With proven reliability, intuitive commissioning, and comprehensive protection features, the MICROMASTER 440 series is trusted by design engineers, system integrators, OEM manufacturers, and facility maintenance teams worldwide. Contact our application engineers for customized drive selection, programming assistance, and technical quotations.
The MICROMASTER 440 VFD is engineered for applications demanding reliable speed regulation, process optimization, and energy efficiency, including:
To facilitate engineering design and drive selection, we provide standardized specifications for the 6SE6440-2UD17-5AA1 model. Custom configurations are available based on project requirements.
| Parameter | Specification |
|---|---|
| Model Number | 6SE6440-2UD17-5AA1 |
| Rated Power | 0.75kW (1HP) |
| Input Voltage | 3AC 380-480V ±10%, 50/60Hz |
| Output Voltage | 0-Input Voltage |
| Output Frequency | 0-650Hz |
| Rated Output Current | 2.2A (at 400V) |
| Overload Capacity | 150% for 60s, 200% for 3s |
| Control Method | V/f control, Sensorless Vector Control |
| Communication Interface | USS via RS485 (standard) |
| Protection Rating | IP20 (chassis), IP55 (optional kit) |
| Ambient Temperature | -10°C to +50°C (derate above 40°C) |
| Dimensions (H×W×D) | 185mm × 145mm × 195mm |
| Mounting | Wall-mount or side-by-side installation |
Selection Recommendations: When selecting a drive, consider motor rated power and current, supply voltage and frequency, load type (constant/variable torque), required control accuracy, communication protocol requirements, and installation environment. For assistance, please provide motor nameplate data, application description, and environmental conditions—our engineers will recommend the optimal model and configuration.
Lead Time: Standard models typically ship within 3-5 business days; custom-configured units require 7-14 days depending on specifications.
Warranty: All drives include a minimum 18-month manufacturer warranty covering defects in materials and workmanship.
Technical Support: We provide remote commissioning assistance, parameter optimization guidance, and on-site startup services (region-dependent). Complete documentation including user manual, quick start guide, parameter list, and wiring diagrams is supplied with each unit.
Certifications: CE, UL, cUL, and RoHS compliant; manufactured in accordance with ISO 9001 quality management standards.
Q: How do I connect the MICROMASTER 440 VFD to my existing motor?
A: The drive connects via standard three-phase motor cables. You'll need to verify motor voltage, current, and power ratings match the drive specifications. Refer to the wiring diagram in the manual, and ensure proper grounding and cable shielding to minimize EMI.
Q: Can this drive control multiple motors simultaneously?
A: A single drive can control one motor at a time. For multi-motor applications, you can use motor contactors with the drive's digital outputs to switch between motors, or deploy multiple drives with centralized control.
Q: What energy savings can I expect in a pump application?
A: Energy savings typically range from 20-50% depending on load profile, system design, and operating conditions. Variable-speed control eliminates throttling losses and reduces average motor load, with greatest savings in systems with highly variable demand.
Q: What are the installation environment requirements? What is the IP rating?
A: Standard units are IP20 (finger-safe, indoor use). Install in a clean, dry, ventilated enclosure with ambient temperature between -10°C and +50°C. IP55 kits are available for dusty or humid environments. Avoid direct sunlight, corrosive gases, and excessive vibration.
Q: Does the drive support remote monitoring and data acquisition?
A: Yes. The standard USS protocol via RS485 enables connection to PLCs, HMIs, and SCADA systems. Optional PROFIBUS-DP, CANopen, and Modbus RTU modules provide additional industrial network connectivity for real-time monitoring, parameter adjustment, and fault logging.
Q: How do I troubleshoot fault codes displayed on the BOP?
A: The BOP displays fault codes (e.g., F001, A502) with brief descriptions. Consult the fault code table in the user manual for detailed diagnostics and corrective actions. Common faults include overcurrent (check motor and cables), overvoltage (check supply), and overtemperature (verify cooling and ventilation).
To receive a detailed selection proposal, pricing, or application-specific technical support, please provide the following information: project name, application type, motor specifications (power, voltage, current), load characteristics, control requirements, communication protocol, and installation environment. Our application engineers will respond with personalized recommendations and documentation within 24 hours.
© 2026 NINERMAS COMPANY LIMITED. All rights reserved.
Original Source: https://ninermas.com
Contact: sale@ninermas.com | +0086 187 5021 5667