Siemens 6SE6400-0PM00-0AA0 Parameter Module for MICROMASTER 440 VFD | Industrial Drive Configuration

(0 reviews)
Manufacturer:
Siemens
Product No.:
6SE6400-1PB00-0AA0
Condition:
1000 in stock
Product Type:
Siemens Simatic S5 & Specialty Modules
Product Origin:
DE
Payment:
T/T, Western Union
Weight:
1.00g
Shipping port:
Xiamen
Warranty:
12 months


Share:

Description

Siemens 6SE6400-0PM00-0AA0 Parameter Module (MICROMASTER 440 Configuration Tool)

The Siemens 6SE6400-0PM00-0AA0 is a dedicated parameter module designed for MICROMASTER 440 series variable frequency drives (VFDs). Through plug-and-play connectivity, it enables rapid parameter configuration, data backup, and drive commissioning, significantly reducing installation time and minimizing configuration errors in industrial automation projects.

Ideal for system integrators, OEM manufacturers, maintenance teams, and automation engineers working with pump control, conveyor systems, HVAC applications, and general-purpose motor control. This module solves common challenges including time-consuming manual parameter entry, risk of configuration loss during drive replacement, inconsistent settings across multiple units, and lack of portable commissioning tools.

With standardized design and field-proven reliability, the 6SE6400-0PM00-0AA0 offers fast parameter transfer, non-volatile memory storage, compact portable form factor, and compatibility across the entire MICROMASTER 440 family. Perfect for design engineers, panel builders, system integrators, and end-user maintenance departments. Contact our application engineers for technical consultation and quotation.

Core Functions & Advantages

  • Rapid Parameter Cloning
    Copy complete drive parameter sets in seconds via the module interface, eliminating repetitive manual entry and ensuring consistent configuration across multiple identical machines or production lines.
  • Non-Volatile Parameter Storage
    Built-in EEPROM memory retains parameter sets indefinitely without power, serving as a reliable backup for critical applications and enabling quick drive replacement without re-commissioning.
  • Simplified Commissioning Workflow
    Pre-configure drive parameters offline using the module, then upload to multiple drives on-site, reducing commissioning time by up to 70% compared to keypad programming methods.
  • Enhanced System Reliability
    Maintain master parameter libraries for different machine types, ensuring standardized configurations and reducing human error during installation, maintenance, or emergency drive replacement scenarios.
  • Plug-and-Play Connectivity
    Direct connection to MICROMASTER 440 RJ45 parameter port requires no additional software or cables, enabling technicians to perform parameter operations without laptop computers or specialized training.
  • Compact & Portable Design
    Pocket-sized module (approximately 85mm × 55mm × 20mm) allows field engineers to carry multiple pre-configured parameter sets for different applications, improving service efficiency and response time.

Typical Application Scenarios

This parameter module is essential for applications requiring efficient drive configuration management and rapid deployment:

  • OEM Machine Manufacturing
    Pre-program standard parameter sets for production machinery, packaging equipment, or material handling systems, then replicate configurations across entire product lines to ensure consistent performance and reduce factory acceptance testing time.
  • Water & Wastewater Treatment
    Store optimized pump control parameters for variable-speed booster systems, sewage lift stations, and chemical dosing applications, enabling quick replacement of failed drives while maintaining precise process control settings.
  • HVAC & Building Automation
    Maintain parameter libraries for fan control, chiller systems, and air handling units across multiple buildings or sites, ensuring standardized energy-saving configurations and simplified maintenance procedures.
  • Industrial Production Lines
    Manage drive parameters for conveyor systems, mixers, extruders, and auxiliary equipment in food processing, chemical manufacturing, or automotive assembly plants, supporting rapid changeover and production flexibility.
  • Service & Maintenance Operations
    Carry backup parameter sets for critical equipment during preventive maintenance visits or emergency service calls, minimizing downtime by enabling immediate drive replacement without waiting for re-commissioning.

Technical Specifications & Selection Guide

To ensure optimal compatibility and performance, please verify the following specifications match your application requirements:

ParameterSpecification
Compatible Drive SeriesMICROMASTER 440 (all power ratings: 0.12 kW to 250 kW)
Connection InterfaceRJ45 parameter port (direct plug-in)
Memory TypeNon-volatile EEPROM
Parameter Storage CapacityOne complete parameter set (all P-parameters)
Data RetentionMinimum 10 years without power
Operating Temperature0°C to +50°C (32°F to 122°F)
Storage Temperature-20°C to +70°C (-4°F to 158°F)
Protection RatingIP20 (for indoor use)
Dimensions (L×W×H)Approximately 85mm × 55mm × 20mm
WeightApproximately 50g
Compliance StandardsCE, UL, cUL certified

Selection Recommendations: When ordering, confirm your MICROMASTER 440 drive firmware version (visible on drive nameplate or parameter P0095). For applications requiring multiple parameter sets, consider ordering multiple modules. For projects involving different drive families (e.g., SINAMICS G120), separate parameter modules are required. Contact our engineering team with your drive model number, application type, and quantity requirements for personalized selection assistance.

Extended Functionality & Integration

  • Parameter Set Management: Organize and label multiple modules for different machine types, process recipes, or customer-specific configurations to streamline commissioning workflows.
  • Version Control: Maintain parameter revision history by dating and documenting module contents, supporting quality management systems (ISO 9001) and traceability requirements.
  • Training & Documentation: Use modules to demonstrate optimal drive settings during technician training programs or to document as-built configurations for equipment manuals and O&M documentation.
  • Remote Site Support: Ship pre-configured modules to remote locations for local installation by non-specialist personnel, reducing travel costs and enabling faster project deployment.

Delivery, Service & Quality Assurance

Lead Time: Standard catalog items typically ship within 3-5 business days from our regional warehouse. For bulk orders (10+ units), please allow 7-10 business days for preparation and quality inspection.

Warranty Coverage: All Siemens 6SE6400-0PM00-0AA0 modules include a 12-month manufacturer warranty covering defects in materials and workmanship. Extended warranty options available upon request.

Technical Support: Our application engineers provide pre-sales consultation, parameter optimization guidance, and post-installation troubleshooting support via phone, email, or remote assistance (subject to regional availability).

Documentation Package: Each module ships with quick start guide, compatibility matrix, and parameter transfer instructions. Complete technical manuals and MICROMASTER 440 programming guides available for download from our technical library.

Quality Certifications: Products sourced through authorized Siemens distribution channels with full traceability. Certificates of conformity and material declarations available upon request for compliance documentation.

Frequently Asked Questions (FAQ)

Q: How do I transfer parameters from a MICROMASTER 440 drive to the 6SE6400-0PM00-0AA0 module?
A: Connect the module to the drive's RJ45 parameter port, navigate to parameter P0010 and set to 1 (commissioning mode), then access P0804 and set to 1 to initiate upload. The drive display will confirm completion. Detailed step-by-step instructions are provided in the quick start guide.

Q: Can one parameter module store settings for multiple different drives?
A: No, each module stores one complete parameter set. For managing multiple configurations, you'll need multiple modules. We recommend labeling each module clearly with application name, machine ID, or configuration date for easy identification.

Q: Is the parameter module compatible with older MICROMASTER 4 series drives?
A: The 6SE6400-0PM00-0AA0 is specifically designed for MICROMASTER 440 series. For MICROMASTER 4 (MM4) drives, a different parameter module (6SE6400-0PM00-0AA1) is required. Please verify your drive series before ordering.

Q: What happens if I connect a module with incompatible parameters to a drive?
A: The MICROMASTER 440 performs automatic compatibility checking during parameter download. If significant mismatches are detected (e.g., different power ratings or firmware versions), the drive will reject the transfer and display an error code, preventing potential damage.

Q: Can the parameter module be used for firmware updates?
A: No, this module only stores and transfers parameter values (P-parameters). Firmware updates for MICROMASTER 440 drives require connection to a PC running STARTER commissioning software via USS or PROFIBUS communication.

Q: How do I verify that parameters were successfully transferred?
A: After download completion, the drive display will show a confirmation message. You can verify critical parameters manually (e.g., P0304 rated motor voltage, P0307 rated motor current) or perform a quick functional test. For comprehensive verification, compare parameter lists using STARTER software.

Request Technical Support & Quotation

For detailed application engineering support, custom parameter development, or volume pricing, please provide the following information to our technical sales team:

  • Project name and application type (pump control, conveyor, HVAC, etc.)
  • MICROMASTER 440 drive model numbers and power ratings
  • Quantity of parameter modules required
  • Delivery location and timeline requirements
  • Any special configuration or documentation needs

Our application engineers will respond within 24 hours with personalized recommendations, parameter optimization suggestions, and competitive quotations.

© 2026 NINERMAS COMPANY LIMITED. All rights reserved.
Original Source: https://ninermas.com
Contact: sale@ninermas.com | +0086 187 5021 5667

Related products