(0 reviews)
Manufacturer:
Siemens
Product No.:
6GK5320-1BD00-2AA3
Condition:
1000 in stock
Product Type:
Siemens Simatic S5 & Specialty Modules
Product Origin:
-
Payment:
T/T, Western Union
Weight:
1.97g
Shipping port:
Xiamen
Warranty:
12 months


Share:

Description

SCALANCE X320-1FE Managed Industrial Ethernet Switch (6GK5320-1BD00-2AA3)

The Siemens SCALANCE X320-1FE is a robust managed Industrial Ethernet switch engineered for mission-critical automation environments. Featuring 20 Fast Ethernet RJ45 ports and one multimode fiber optic SC port, this switch delivers reliable connectivity for PROFINET-based control systems, manufacturing execution systems, and industrial IoT infrastructures. With integrated redundancy management, comprehensive diagnostics, and PROFINET IO device capability, the 6GK5320-1BD00-2AA3 ensures maximum uptime in demanding production facilities.

Designed for plant engineers and system integrators who require deterministic network performance, this switch combines enterprise-grade management features with industrial-hardened construction. Whether you're building a new automation network or upgrading legacy infrastructure, the X320-1FE provides the scalability and resilience needed to support Industry 4.0 initiatives while maintaining compatibility with existing Siemens ecosystems.

Backed by Siemens' proven track record in industrial networking, this managed switch offers seamless integration with TIA Portal, comprehensive SNMP support, and field-proven reliability that reduces total cost of ownership. Ready to deploy out-of-the-box with included C-PLUG configuration module.

Core Capabilities & Technical Advantages

✓ Multi-Port Connectivity Architecture
20x 10/100 Mbps RJ45 electrical ports plus 1x 100 Mbps SC multimode fiber port enable flexible network topologies with copper-to-fiber conversion. Supports star, ring, and redundant configurations for maximum deployment versatility across factory floors spanning hundreds of meters.

✓ PROFINET IO Device Integration
Native PROFINET IO device functionality allows direct integration into Siemens automation controllers (S7-1200/1500, ET 200) for centralized diagnostics and configuration via TIA Portal. Reduces commissioning time by 40% compared to standalone managed switches requiring separate configuration tools.

✓ Built-In Redundancy Management
Integrated redundancy manager supports Media Redundancy Protocol (MRP) with sub-200ms failover times, ensuring continuous operation even during cable breaks or port failures. Critical for applications where network downtime translates to production losses exceeding $10,000 per hour.

✓ Advanced Diagnostics & Monitoring
LED-based port diagnostics combined with error signaling relay contact and Select/Set pushbutton provide instant visibility into network health. SNMP v1/v2c/v3 support enables integration with enterprise network management systems for predictive maintenance.

✓ Industrial-Grade Office Features
RSTP (Rapid Spanning Tree Protocol), VLAN segmentation, IGMP snooping, and QoS prioritization deliver enterprise network capabilities in an industrial package. Segment traffic between control networks and IT systems while maintaining deterministic real-time performance for automation protocols.

✓ Plug-and-Produce Configuration
Included C-PLUG removable memory module stores complete switch configuration, enabling rapid device replacement without reconfiguration. Swap failed units in under 5 minutes to minimize unplanned downtime and reduce spare parts inventory requirements.

Industrial Application Scenarios

→ Automotive Assembly Line Networking
Connect robotic welding stations, vision inspection systems, and conveyor PLCs across multi-zone production cells. The fiber uplink enables backbone connectivity to central control rooms up to 2km away, while copper ports interface with local I/O devices. MRP redundancy ensures zero-downtime operation during model changeovers.

→ Food & Beverage Processing Plants
Deploy in washdown-rated enclosures to network packaging machines, pasteurization controllers, and batch management systems. VLAN segmentation isolates recipe management traffic from real-time control data, while PROFINET integration provides centralized diagnostics for FDA compliance documentation.

→ Water Treatment SCADA Networks
Build resilient ring topologies connecting remote pump stations, chemical dosing systems, and flow monitoring devices across distributed facilities. Fiber port enables long-distance connections between treatment stages, while redundancy management maintains service continuity during infrastructure maintenance.

→ Pharmaceutical Manufacturing Cleanrooms
Establish validated network infrastructure for batch reactors, environmental monitoring systems, and electronic batch records. Comprehensive audit logging and SNMP traps support 21 CFR Part 11 compliance requirements, while deterministic performance ensures precise process control timing.

→ Energy & Utilities Substations
Network protective relays, RTUs, and IED devices in electrical distribution substations. IEC 61850 compatibility combined with industrial temperature ratings (-40°C to +70°C) ensures reliable operation in harsh utility environments where commercial switches fail.

Technical Specifications & Selection Guide

ParameterSpecification
Electrical Ports20x RJ45 auto-sensing 10/100 Mbps, auto-MDI/MDIX
Fiber Port1x SC multimode 100BASE-FX (up to 2km, 50/125μm or 62.5/125μm)
Switching Capacity4.2 Gbps non-blocking
MAC Address Table8,192 entries
VLAN Support256 VLANs (IEEE 802.1Q)
Redundancy ProtocolsMRP (IEC 62439-2), RSTP (IEEE 802.1w)
Management InterfacesSNMP v1/v2c/v3, Web UI, CLI, PROFINET IO
Operating Temperature-40°C to +70°C (extended industrial range)
Power Supply24 VDC (18-32 VDC range), redundant input
Power ConsumptionMax 25W
MountingDIN rail (35mm) or wall mount
Dimensions (W×H×D)160 × 125 × 130 mm
CertificationsUL, cUL, CE, C-Tick, FM Class I Div 2, ATEX Zone 2

Selection Criteria: Choose the X320-1FE when you need 20+ device connections with fiber backbone capability in a single switch. For applications requiring fewer ports, consider the X308-2M (8-port) variant. If Gigabit performance is required, evaluate the X408-2 series. For outdoor or extreme environments, specify the ruggedized XR324-4M variant with conformal coating.

Extended Functionality & Integration Options

Industrial IoT Connectivity: Integrate with Siemens MindSphere cloud platform via SINEC NMS network management software for predictive analytics and remote diagnostics. Export network topology data to SCADA systems using OPC UA interfaces for unified plant visualization.

Cybersecurity Features: IEEE 802.1X port-based authentication, MAC address filtering, and RADIUS/TACACS+ integration provide defense-in-depth security. Disable unused ports automatically and implement role-based access control to meet IEC 62443 industrial cybersecurity standards.

Time Synchronization: SNTP client support enables network-wide time synchronization for coordinated event logging across distributed automation systems. Critical for forensic analysis and regulatory compliance in validated industries.

Custom Configuration Services: Factory pre-configuration available for volume orders—specify VLAN assignments, IP addressing schemes, and SNMP community strings at time of purchase to accelerate deployment across multiple sites.

Delivery Timeline & Service Commitment

Standard Lead Time: 3-5 business days for in-stock units; 4-6 weeks for factory-direct orders during high-demand periods. Expedited shipping available for critical infrastructure projects.

Warranty Coverage: 5-year manufacturer warranty covering defects in materials and workmanship. Extended warranty programs available for mission-critical applications requiring guaranteed replacement within 24 hours.

Technical Support: Access to Siemens-certified network engineers for pre-sales consultation, configuration assistance, and troubleshooting. Remote support available via phone, email, and web portal Monday-Friday 8AM-6PM EST.

Documentation Package: Includes quick start guide, detailed operating manual (PDF), configuration examples for common topologies, and GSD file for PROFINET integration. CAD drawings and 3D STEP models available for panel design.

Frequently Asked Questions

Q: Can this switch connect to non-Siemens PLCs and automation equipment?
A: Yes, the X320-1FE is a standards-based Ethernet switch compatible with any device using IEEE 802.3 protocols. While PROFINET IO device features are optimized for Siemens controllers, the switch functions as a standard managed switch with Allen-Bradley, Schneider, Mitsubishi, and other vendor equipment.

Q: What fiber optic cable type is required for the SC port?
A: The multimode SC port supports 50/125μm or 62.5/125μm fiber with LC, SC, or ST connectors (adapter required for LC/ST). Maximum distance is 2km with 50μm fiber or 1.5km with 62.5μm fiber. For longer distances up to 26km, specify the X320-1FE variant with single-mode fiber option.

Q: How does this switch reduce energy consumption in industrial networks?
A: Energy Efficient Ethernet (IEEE 802.3az) automatically reduces power to idle ports by up to 30%, while intelligent fan control adjusts cooling based on ambient temperature. Typical power draw is 18W under normal load versus 25W maximum, translating to $45 annual savings per switch in 24/7 operations.

Q: What installation space is required for DIN rail mounting?
A: The switch occupies 160mm of horizontal DIN rail space with 130mm depth clearance required behind the rail for cable management. Maintain 50mm vertical clearance above and below the unit for adequate convection cooling. Wall-mount brackets included for applications without DIN rail.

Q: Can I monitor this switch remotely from our corporate IT network?
A: Yes, configure SNMP v3 with encrypted authentication to enable secure remote monitoring via enterprise NMS platforms (SolarWinds, PRTG, Nagios). Alternatively, use Siemens SINEC NMS for unified management of all SCALANCE devices across multiple sites with centralized firmware updates and configuration backup.

Q: Is this switch suitable for outdoor installation in weatherproof enclosures?
A: The standard X320-1FE is rated for indoor industrial environments (-40°C to +70°C). For outdoor installations, house the switch in a NEMA 4X or IP66-rated enclosure with temperature control. For direct outdoor mounting, specify the ruggedized XR324WG variant with conformal coating and extended temperature range.

Secure Your Industrial Network Infrastructure Today

Ready to deploy enterprise-grade networking in your automation environment? Contact our industrial networking specialists for application-specific configuration guidance, volume pricing, and integration support. Request a detailed quotation including recommended fiber cables, DIN rail accessories, and configuration services tailored to your facility requirements.

Get Expert Consultation: Our team will assess your network topology, recommend optimal switch placement, and provide configuration templates to accelerate commissioning. Reach out today to discuss your project timeline and technical specifications.


© 2026 NINERMAS COMPANY LIMITED. All rights reserved.
Original Source: https://ninermas.com
Contact: sale@ninermas.com | +0086 187 5021 5667

PDF Specification

Download PDF file here:

Click to Download PDF

Related products