The Siemens 6GK1503-2CB00 is an industrial-grade PROFIBUS DP optical link module designed for reliable fiber optic communication in demanding automation environments. Through advanced optical transmission technology and PROFIBUS DP protocol support, it enables high-speed data exchange, electromagnetic interference immunity, and extended transmission distances up to 15 kilometers.
Ideal for manufacturing plants, process automation facilities, power substations, and distributed control systems where electrical isolation and long-distance communication are critical. This module solves common challenges including electromagnetic interference in high-voltage areas, ground loop issues, lightning protection requirements, and the need for secure data transmission across large industrial sites.
Featuring standardized PROFIBUS DP interface and flexible fiber optic connectivity options, the 6GK1503-2CB00 offers seamless integration with existing SIMATIC systems, proven reliability in harsh industrial conditions, hot-swappable design for minimal downtime, and comprehensive diagnostic capabilities. Suitable for system integrators, automation engineers, plant maintenance teams, and OEM equipment manufacturers. Contact our technical team for application-specific configuration guidance and quotation.
This PROFIBUS optical link module is engineered for industrial environments requiring robust, interference-free communication over extended distances, particularly in:
To ensure optimal system performance and compatibility, the following technical parameters are provided for design and procurement reference. Custom configurations are available based on specific project requirements.
| Parameter | Specification |
|---|---|
| Product Model | 6GK1503-2CB00 |
| Protocol Support | PROFIBUS DP (EN 50170) |
| Transmission Rate | 9.6 kbps to 12 Mbps (auto-detection) |
| Fiber Type | Multimode 62.5/125 μm or 50/125 μm; Single-mode 9/125 μm |
| Optical Connector | BFOC (ST-type) bayonet connector |
| Max Distance (Multimode) | Up to 15 km @ 1.5 Mbps |
| Max Distance (Single-mode) | Up to 26 km @ 1.5 Mbps |
| Operating Voltage | 24 VDC (20.4 - 28.8 VDC) |
| Power Consumption | Typical 3W, Max 5W |
| Operating Temperature | -25°C to +60°C |
| Storage Temperature | -40°C to +70°C |
| Protection Rating | IP20 |
| Mounting | DIN rail (35mm standard rail) |
| Dimensions (W×H×D) | 40 mm × 125 mm × 120 mm |
| Certifications | CE, UL, PROFIBUS certified |
Selection Recommendations: When specifying this module, consider the following factors: required transmission distance and fiber type availability, existing PROFIBUS network baud rate settings, environmental conditions (temperature, vibration, EMI levels), power supply infrastructure (24VDC availability), and physical installation space constraints. For applications requiring distances beyond 15km or special environmental protection, consult with our application engineers who can recommend appropriate fiber types, signal repeaters, or alternative solutions. Provide your network topology diagram and site conditions for customized configuration assistance.
Lead Time: Standard stock items ship within 3-5 business days; custom-configured systems or bulk orders typically require 10-15 business days depending on quantity and specifications.
Warranty Coverage: All modules include a comprehensive 12-month manufacturer warranty covering defects in materials and workmanship, with optional extended warranty programs available for critical applications.
Technical Support: Our certified automation engineers provide pre-sales consultation, system design assistance, installation guidance, and post-sales troubleshooting support via phone, email, and remote diagnostics (region-dependent).
Documentation Package: Each shipment includes complete technical documentation: product datasheet, installation manual, wiring diagrams, PROFIBUS configuration guidelines, GSD device files, and compliance certificates for seamless commissioning and maintenance.
Quality Certifications: Products are sourced through authorized distribution channels, undergo incoming quality inspection, and are backed by genuine Siemens quality standards and international certifications (CE, UL, PROFIBUS certification).
Q: How do I connect the 6GK1503-2CB00 PROFIBUS optical link module to my existing copper-based PROFIBUS network?
A: The module acts as a media converter between electrical PROFIBUS (RS-485) and optical fiber. Connect your existing copper PROFIBUS segment to the module's electrical port (9-pin D-sub connector), then use fiber optic cables to extend the network. You'll need one module at each end of the fiber link. Ensure both modules are configured for the same baud rate as your PROFIBUS network (auto-detection is supported).
Q: What is the maximum number of optical link modules I can use in a single PROFIBUS network?
A: You can cascade multiple optical segments within PROFIBUS DP specifications. Each fiber segment can span up to 15km (multimode) or 26km (single-mode), and you can use multiple segments to extend total network reach. However, total network delay and the maximum 126 PROFIBUS addresses remain limiting factors. For complex topologies, consult PROFIBUS network planning guidelines or contact our engineers for design validation.
Q: What type of fiber optic cable should I use, and are there specific connector requirements?
A: The 6GK1503-2CB00 supports both multimode (62.5/125μm or 50/125μm) and single-mode (9/125μm) fiber. Use multimode for distances up to 3km for cost-effectiveness; single-mode for longer distances up to 26km. The module uses BFOC (ST-type) bayonet connectors. Ensure fiber cables are industrial-grade with appropriate jacket protection for your installation environment (indoor/outdoor, rodent protection, etc.).
Q: Can this module be used in redundant PROFIBUS networks for high-availability applications?
A: Yes, the 6GK1503-2CB00 is compatible with PROFIBUS DP redundancy architectures. You can implement redundant fiber rings or dual-channel configurations using appropriate PROFIBUS redundancy controllers and switches. The module supports seamless failover when integrated with redundant-capable PLCs and I/O systems. Specific configuration depends on your redundancy strategy (S2 system redundancy, H-system, etc.).
Q: What are the installation environment requirements, and what protection rating does the module have?
A: The module is rated IP20 for standard control cabinet installation and operates reliably in -25°C to +60°C ambient temperature. It requires DIN rail mounting in an enclosed cabinet with adequate ventilation. For harsh environments (dust, moisture, extreme temperatures), install in climate-controlled enclosures with appropriate IP65/IP66 rating. Ensure 24VDC power supply is stable and within 20.4-28.8VDC range.
Q: Does the module support remote monitoring and diagnostics via PROFIBUS or industrial Ethernet?
A: The module provides comprehensive diagnostics via PROFIBUS DP protocol, including optical signal quality, transmission errors, and module status, which can be monitored through your PLC program or SCADA system. Front-panel LEDs indicate power, optical link status, and communication activity for local troubleshooting. For Ethernet-based remote monitoring, integrate with SIMATIC controllers that bridge PROFIBUS data to PROFINET or industrial IoT platforms.
To receive detailed application engineering support, customized system design, or project quotation, please provide the following information to our technical team:
Our certified automation engineers will provide one-on-one consultation, recommend optimal configuration, and deliver competitive pricing within 24 business hours.
© 2026 NINERMAS COMPANY LIMITED. All rights reserved.
Original Source: https://ninermas.com
Contact: sale@ninermas.com | +0086 187 5021 5667