The Siemens PS 407 20A Power Supply (6ES7407-0DA02-0AA0) is a high-performance industrial power module engineered for S7-400 programmable logic controller (PLC) systems. Through precision voltage regulation and redundancy-ready architecture, it delivers stable 24V DC output to ensure uninterrupted operation of automation backplanes, I/O modules, and communication processors in mission-critical environments.
Designed for process industries, manufacturing plants, energy facilities, and building automation systems, this power supply addresses challenges such as voltage fluctuations, power interruptions, and system downtime. It helps eliminate unexpected shutdowns, protects sensitive control hardware, and reduces maintenance overhead in 24/7 production environments.
With standardized DIN rail mounting and flexible input voltage options (120/230V AC), the PS 407 integrates seamlessly into existing S7-400 racks. It is ideal for system integrators, control panel builders, OEM equipment manufacturers, and plant maintenance teams seeking reliable, long-life power solutions. Contact our automation engineers for application-specific sizing, redundancy configuration, or technical documentation.
This power supply is engineered for environments demanding high reliability, continuous operation, and precise voltage regulation:
To facilitate system design and procurement, key electrical and mechanical parameters are outlined below. Custom configurations and extended temperature variants are available upon request.
| Parameter | Specification |
|---|---|
| Part Number | 6ES7407-0DA02-0AA0 |
| Output Voltage | 24V DC ±3% |
| Output Current | 20A (continuous) |
| Input Voltage | 120/230V AC ±15% (auto-sensing) |
| Input Frequency | 47-63 Hz |
| Efficiency | ≥ 88% |
| Redundancy Support | Yes (with diode module) |
| Mounting | DIN rail (35mm, S7-400 rack compatible) |
| Protection Class | IP20 |
| Operating Temperature | 0°C to +60°C |
| Certifications | CE, UL, cULus |
| MTBF | > 500,000 hours |
Selection Recommendations: When sizing the power supply, calculate total current draw from all installed S7-400 modules (CPU, communication processors, I/O cards) and add 20-30% margin for future expansion. For critical applications, implement redundant power configuration using two PS 407 units with diode module 6ES7405-0DA02-0AA0. Consult our engineering team with your rack configuration, ambient temperature, and uptime requirements for tailored recommendations.
Lead Time: Standard units ship within 3-5 business days from our regional distribution centers. Custom configurations or bulk orders typically require 10-15 business days.
Warranty: All units include a 12-month manufacturer warranty covering defects in materials and workmanship. Extended warranty options available.
Technical Support: Our automation specialists provide pre-sales sizing assistance, installation guidance, and post-sales troubleshooting. Remote diagnostic support and on-site commissioning services available in select regions.
Documentation Package: Each unit ships with installation manual, electrical wiring diagrams, dimensional drawings, and compliance certificates. CAD files and 3D models available for download.
Q: How do I integrate the PS 407 power supply with my existing S7-400 rack?
A: The PS 407 mounts directly onto standard 35mm DIN rail within the S7-400 rack. Connect AC input to L/N terminals, and DC output connects to the backplane bus. Verify total module current draw does not exceed 20A. Refer to installation manual section 3.2 for detailed wiring diagrams.
Q: Can I use this power supply in a redundant configuration?
A: Yes. Install two PS 407 units with a 6ES7405-0DA02-0AA0 diode module to achieve N+1 redundancy. In case of primary supply failure, the secondary unit automatically assumes full load without system interruption.
Q: What is the typical energy efficiency and heat dissipation?
A: The PS 407 operates at ≥88% efficiency. At full 20A load, expect approximately 60W heat dissipation. Ensure adequate ventilation in enclosed cabinets; maintain ambient temperature below 60°C for optimal lifespan.
Q: Is this power supply suitable for harsh industrial environments?
A: The unit is rated IP20 for standard control cabinet installation. For dusty or humid environments, install within a sealed NEMA 4/IP65 enclosure. Operating temperature range is 0-60°C; for extreme conditions, consult us for conformal-coated or extended-temperature variants.
Q: Does the PS 407 support remote monitoring and diagnostics?
A: Yes. The power supply provides diagnostic signals to the S7-400 backplane, accessible via CPU diagnostic buffer. Integrate with SCADA systems using PROFIBUS/PROFINET for centralized monitoring of voltage levels, load current, and fault status.
Q: What certifications does this product hold?
A: The 6ES7407-0DA02-0AA0 is CE, UL, and cULus certified, meeting international safety and EMC standards for industrial control equipment. Compliance documentation available upon request.
For detailed application engineering, custom panel integration, or volume pricing, please provide the following information:
Our automation engineers will respond within 24 hours with sizing recommendations, technical documentation, and competitive quotations.
© 2026 NINERMAS COMPANY LIMITED. All rights reserved.
Original Source: https://ninermas.com
Contact: sale@ninermas.com | +0086 187 5021 5667