The Siemens 6ES7407-0DA00-0AA0 PS 407 is a high-performance 10A power supply module designed specifically for S7-400 PLC systems, delivering stable and reliable DC power through advanced switching technology. It ensures continuous operation in demanding industrial environments such as process control, manufacturing automation, and critical infrastructure applications.
Ideal for system integrators, design engineers, and plant maintenance teams working with distributed control systems (DCS), programmable logic controllers (PLC), and SCADA networks. This module addresses common challenges including voltage fluctuations, redundancy requirements, limited rack space, and the need for hot-swappable power solutions in 24/7 operations.
With standardized design and flexible configuration options, the PS 407 offers universal voltage input compatibility, redundancy support for mission-critical systems, compact DIN rail mounting, and comprehensive protection features. Suitable for OEMs, panel builders, system integrators, and end-user facilities across energy, chemicals, water treatment, and heavy manufacturing sectors. Contact our application engineers for customized power architecture recommendations and technical specifications.
This power supply module is engineered for industrial environments requiring high reliability, continuous availability, and precise voltage regulation, particularly in:
To facilitate system design and component selection, we provide comprehensive electrical, mechanical, and environmental specifications. Custom configurations available based on project-specific requirements.
| Parameter | Specification |
|---|---|
| Model Number | 6ES7407-0DA00-0AA0 |
| Product Series | SIMATIC S7-400 PS 407 |
| Input Voltage Range | 120/230V AC ±15% (auto-sensing) |
| Input Frequency | 47-63 Hz |
| Output Voltage | 24V DC ±3% |
| Output Current | 10A continuous |
| Output Power | 240W |
| Efficiency | ≥88% (typical) |
| Redundancy Support | Yes (parallel operation capable) |
| Mounting Type | DIN rail (35mm standard) |
| Protection Class | IP20 |
| Operating Temperature | 0°C to +60°C |
| Storage Temperature | -40°C to +70°C |
| Dimensions (W×H×D) | Approx. 80mm × 290mm × 210mm |
| Weight | Approx. 1.0 kg |
| Certifications | CE, UL, cUL, FM |
Selection Recommendations: When specifying power supplies for S7-400 systems, consider total current consumption of all installed modules (CPU, communication processors, I/O cards), ambient temperature conditions, required redundancy level, and available panel space. For systems exceeding 8A load or requiring N+1 redundancy, consult our application engineers with your I/O configuration list, environmental parameters, and uptime requirements for optimized power architecture design.
Lead Time: Genuine Siemens factory-sealed units typically ship within 3-5 business days for stock items; custom configurations or large quantity orders may require 2-3 weeks lead time depending on regional availability.
Warranty Coverage: All units include minimum 12-month manufacturer warranty covering defects in materials and workmanship. Extended warranty options available for critical applications.
Technical Support: Comprehensive support package includes installation guidance, wiring diagrams, configuration assistance, and troubleshooting support via phone, email, or remote session. On-site commissioning services available in select regions (subject to project scope and location).
Documentation Package: Each unit ships with complete technical documentation including product datasheet, electrical schematic, terminal connection diagram, DIP switch settings (if applicable), and multilingual operation manual in PDF format for integration into project documentation.
Quality Assurance: All products sourced through authorized distribution channels with full traceability. Factory calibration certificates and material compliance declarations (RoHS, REACH) available upon request for regulated industries.
Q: How do I integrate the PS 407 10A power supply with my existing S7-400 PLC rack configuration?
A: The PS 407 mounts directly onto standard S7-400 profile rails and connects via the backplane bus. Verify your total system current draw (sum of all module consumption values from datasheets), ensure it does not exceed 10A, and confirm input voltage matches your panel power distribution (120V or 230V AC). Detailed connection procedures are provided in the installation manual.
Q: What is the maximum number of S7-400 modules one PS 407 unit can power?
A: Power capacity depends on individual module consumption rather than quantity. A fully loaded rack with CPU 414, multiple communication processors, and analog I/O typically draws 6-8A. Calculate total current by summing values from each module's technical specifications. For systems approaching 8A or requiring future expansion headroom, consider redundant power supply configuration.
Q: What energy savings can I expect compared to older linear power supply designs?
A: The PS 407 switching power supply achieves approximately 88% efficiency compared to 50-60% for legacy linear designs, reducing heat dissipation by up to 40% and lowering cooling requirements in control cabinets. Actual savings depend on load profile and ambient conditions; typical installations see 30-35% reduction in power consumption for the power supply subsystem.
Q: What are the environmental requirements for installation? What is the IP protection rating?
A: Rated IP20 for indoor industrial environments. Requires ambient temperature 0-60°C, relative humidity 5-95% non-condensing, and pollution degree 2 per IEC 61131-2. Avoid direct exposure to corrosive gases, conductive dust, or condensation. For harsh environments (chemical plants, outdoor enclosures), install within IP54+ rated control cabinet with adequate ventilation.
Q: Does this power supply support remote monitoring and data acquisition protocols?
A: The PS 407 provides local diagnostic status via LED indicators and backplane communication to the S7-400 CPU for basic health monitoring. For advanced remote monitoring (SNMP, OPC UA, Modbus TCP), integrate with Siemens SIMATIC NET communication modules or third-party monitoring gateways that interface with the S7-400 system diagnostics.
Q: Can I use this power supply in a redundant N+1 configuration for critical applications?
A: Yes, the PS 407 is designed for redundant parallel operation. Install two or more units on the same S7-400 rack; built-in diode-OR logic automatically load-shares and provides seamless failover if one unit fails. Ensure total load does not exceed N×10A where N is the number of installed power supplies. Redundancy configuration requires no additional hardware or programming.
For detailed selection assistance, custom power architecture design, or project quotations, please provide the following information to our application engineering team:
Our engineers will provide one-on-one consultation including load calculation verification, thermal analysis, and optimized component recommendations within 24 business hours.
© 2026 NINERMAS COMPANY LIMITED. All rights reserved.
Original Source: https://ninermas.com
Contact: sale@ninermas.com | +0086 187 5021 5667