The Siemens 6ES7307-1KA01-0AA0 PS307 is a high-reliability stabilized power supply designed specifically for SIMATIC S7-300 PLC systems and industrial automation applications. Through precision voltage regulation and robust circuit protection, it delivers consistent 24V DC power at up to 10A output capacity, ensuring stable operation of controllers, I/O modules, and field devices in demanding industrial environments.
Ideal for manufacturing automation, process control systems, building management installations, and machine control panels where power stability directly impacts production uptime. This module addresses common challenges including input voltage fluctuations, electrical noise interference, overload conditions, and the need for reliable backup power integration in mission-critical control systems.
Engineered with Siemens' proven design standards and global certification compliance, the PS307 offers wide input voltage tolerance, comprehensive diagnostic capabilities, and seamless integration with S7-300 racks. Suitable for system integrators, control panel builders, OEM manufacturers, and plant maintenance teams requiring dependable power solutions. Contact our application engineers for system configuration assistance and technical specifications tailored to your project requirements.
This power supply module is engineered for industrial environments requiring high availability and precise voltage control, particularly in:
To ensure optimal system performance and proper power budget allocation, review the following technical parameters. Our engineering team can assist with load calculations and redundancy planning based on your specific application requirements.
| Parameter | Specification |
|---|---|
| Model Number | 6ES7307-1KA01-0AA0 |
| Output Voltage | 24V DC (±3% regulation) |
| Output Current | 10A continuous, 12A peak (5s) |
| Output Power | 240W rated |
| Input Voltage | 120/230V AC (85-264V AC range) |
| Input Frequency | 47-63 Hz |
| Efficiency | ≥88% at nominal load |
| Mounting Type | 35mm DIN rail (EN 50022) |
| Dimensions (W×H×D) | 70 × 125 × 120 mm |
| Operating Temperature | 0°C to +60°C (horizontal mounting) |
| Protection Rating | IP20 (panel-mounted installation) |
| Certifications | UL, CSA, CE, cULus Listed |
| MTBF | ≥300,000 hours (per SN 29500) |
Selection Considerations: When specifying this power supply, calculate total system load including PLC CPU base current, all installed I/O modules, communication processors, and connected field devices. Recommended practice is to maintain 20-30% power reserve margin for future expansion and to account for inrush currents during startup. For systems requiring N+1 redundancy, consider parallel operation with SITOP redundancy modules. Consult our application engineers with your I/O configuration list, ambient temperature conditions, and installation environment details for validated power system design.
Lead Time: Factory-sealed units typically ship within 3-5 business days from stock. Custom configurations or bulk orders may require 10-15 business days—contact our sales team for expedited delivery options and project-specific scheduling.
Warranty Coverage: All Siemens PS307 modules include manufacturer's standard warranty covering defects in materials and workmanship. Extended warranty programs and advance replacement services available for critical applications.
Technical Support: Our certified automation specialists provide pre-sales application engineering, installation guidance, and post-delivery technical assistance. Remote diagnostic support and on-site commissioning services available depending on project scope and geographic location.
Documentation Package: Each unit ships with complete technical documentation including electrical specifications datasheet, dimensional drawings, DIN rail mounting instructions, wiring diagrams, and multilingual operation manual. CAD models and EPLAN macros available for download to streamline panel design workflows.
Q: How do I integrate the PS307 power supply with my existing S7-300 PLC rack system?
A: The PS307 mounts directly onto standard 35mm DIN rail alongside your S7-300 CPU and I/O modules. Connect AC input to L/N terminals, bond PE ground, and distribute 24V DC output to the PLC backplane power bus. Verify total system current draw does not exceed 10A continuous rating. Refer to S7-300 installation manual chapter 4 for detailed backplane wiring procedures.
Q: What is the maximum number of I/O modules this power supply can support?
A: Capacity depends on specific module types—typical S7-300 digital I/O modules consume 50-150mA each, while analog and communication modules may draw 200-500mA. A fully populated 11-slot rack with mixed I/O typically requires 6-8A. Use Siemens TIA Selection Tool or consult module datasheets to calculate precise load requirements for your configuration.
Q: What energy efficiency improvements can I expect compared to older linear power supplies?
A: The PS307 switching regulator design achieves ≥88% efficiency versus 50-60% for legacy linear supplies, reducing heat dissipation by approximately 40-50% and lowering panel cooling requirements. In a typical 24/7 industrial application, this translates to 150-200 kWh annual energy savings per unit and extended component lifespan due to reduced thermal stress.
Q: What are the environmental and installation requirements for reliable operation?
A: Maintain ambient temperature between 0-60°C with horizontal DIN rail mounting (derate output current 2.5% per °C above 60°C for vertical mounting). Ensure minimum 25mm clearance above/below unit for convection cooling. IP20 rating requires installation inside enclosed control cabinet. Avoid direct exposure to condensation, corrosive gases, or conductive dust—use sealed enclosures in harsh environments.
Q: Does this power supply support remote monitoring and predictive maintenance integration?
A: Yes, the PS307 provides DC OK and fault signaling contacts that interface with PLC digital inputs, SCADA systems, or IoT gateways. Monitor output voltage status, overload conditions, and operational hours for condition-based maintenance scheduling. For advanced diagnostics, consider SITOP PSE200U monitoring module (6EP1961-3BA21) which adds Ethernet connectivity and detailed power quality analytics.
Q: Can I operate multiple PS307 units in parallel for higher current capacity or redundancy?
A: Direct parallel operation is not recommended without proper decoupling. For increased capacity, use higher-current SITOP models (PS307 20A variant or modular PSU6200 series). For N+1 redundancy, deploy Siemens redundancy modules (6EP1961-2BA00) which provide ORing diode isolation and automatic load sharing between multiple power supplies—essential for high-availability applications.
To receive detailed system design recommendations, competitive pricing, or application-specific technical support, please provide our engineering team with the following project information:
Our certified automation specialists will provide personalized selection guidance, validated power budget calculations, and comprehensive quotations within 24 business hours.
© 2026 NINERMAS COMPANY LIMITED. All rights reserved. Original Source: https://ninermas.com Contact: sale@ninermas.com | +0086 187 5021 5667