The Siemens SIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA0) is a high-performance programmable logic controller engineered for small to medium-scale automation applications. Featuring integrated Ethernet connectivity, onboard digital I/O, and seamless TIA Portal programming environment, this CPU delivers reliable control for manufacturing lines, packaging equipment, HVAC systems, and building automation infrastructure.
Designed for system integrators, machine builders, and facility engineers who demand precision control with minimal footprint, the CPU SR40 addresses common challenges including limited panel space, complex wiring requirements, inconsistent communication protocols, and time-consuming commissioning processes. Its modular architecture allows flexible expansion while maintaining compact dimensions.
Through standardized design and customizable I/O configurations, this controller offers rapid deployment, robust performance, proven reliability, and excellent compatibility with existing Siemens ecosystems. Ideal for design consultants, automation contractors, OEM manufacturers, and end-user industrial facilities. Contact our application engineers for tailored system configuration and technical quotations.
This controller excels in applications requiring reliable logic control, precise timing, and network connectivity:
To facilitate engineering design and system selection, we provide standardized technical parameters. Custom configurations available based on project-specific requirements.
| Parameter | Specification |
|---|---|
| CPU Type | SIMATIC S7-200 SMART CPU SR40 |
| Part Number | 6ES7288-1SR40-0AA0 |
| Program Memory | 40 KB |
| Data Memory | 30 KB |
| Onboard Digital Inputs | 14 x 24VDC sink/source |
| Onboard Digital Outputs | 10 x relay (2A) / transistor options |
| Ethernet Ports | 1 x RJ45 10/100 Mbps |
| Expansion Capability | Up to 8 signal modules |
| Power Supply | 24VDC (20.4-28.8VDC range) |
| Operating Temperature | -20°C to +60°C |
| Protection Rating | IP20 (enclosure dependent) |
| Programming Software | TIA Portal V13 or higher |
| Mounting | Standard DIN rail |
| Dimensions (W×H×D) | 90mm × 100mm × 81mm |
| Certifications | CE, UL, cULus, RCM |
Selection Recommendations: When specifying this controller, consider maximum I/O count requirements, communication protocol needs, environmental conditions, power supply availability, and panel space constraints. For applications requiring analog signal processing, high-speed counting, or motion control, consult our engineering team with process parameters for optimized module selection and system architecture design.
Standard catalog items ship from stock within 3-5 business days; custom-configured systems with expansion modules typically deliver within 10-15 business days. All products include minimum 12-month manufacturer warranty with extended service agreements available. We provide remote technical consultation and on-site commissioning support (region-dependent).
Complete technical documentation package includes electrical schematics, I/O wiring diagrams, TIA Portal sample programs, communication setup guides, and maintenance procedures to streamline installation and ongoing service operations.
Q: How does the SIMATIC S7-200 SMART CPU SR40 integrate with existing automation systems?
A: The CPU SR40 features standard Ethernet connectivity supporting PROFINET and Modbus TCP protocols, allowing direct integration with most HMI panels, SCADA systems, and industrial networks. Verify your system's communication protocol requirements and IP addressing scheme before deployment.
Q: What is the maximum I/O capacity when using expansion modules?
A: The CPU SR40 supports up to 8 signal modules, enabling total system expansion to 280+ I/O points (digital and analog combined). Actual capacity depends on specific module types selected and power budget considerations.
Q: Can this controller be programmed using ladder logic?
A: Yes, the S7-200 SMART series is fully programmable using Siemens TIA Portal software with support for ladder diagram (LAD), function block diagram (FBD), and structured control language (SCL) programming methods.
Q: What environmental protection rating does this CPU provide?
A: The standard housing provides IP20 protection suitable for controlled industrial environments. For harsh conditions with dust, moisture, or chemical exposure, install within IP54 or higher rated enclosures with appropriate environmental sealing.
Q: Does the CPU SR40 support remote monitoring and data logging?
A: Yes, the integrated Ethernet interface and web server functionality enable remote access for real-time monitoring, alarm notification, and data trending. Additional SCADA integration or cloud connectivity can be implemented via standard industrial protocols.
Q: What is the typical power consumption and heat dissipation?
A: The CPU SR40 typically consumes 5-8W depending on I/O loading and communication activity, with minimal heat generation suitable for compact panel installations. Ensure adequate ventilation per installation guidelines.
For detailed application engineering, system sizing, or technical quotations, please provide the following project information: application description, required I/O count and types, communication protocol requirements, environmental conditions, power supply specifications, and any special certifications needed. Our automation specialists will deliver personalized selection recommendations and competitive pricing within 24-48 hours.
© 2026 NINERMAS COMPANY LIMITED. All rights reserved.
Original Source: https://ninermas.com
Contact: sale@ninermas.com | +0086 187 5021 5667