(0 reviews)
Manufacturer:
Siemens
Product No.:
2XV9450-1AR22
Condition:
1000 in stock
Product Type:
Siemens Simatic S5 & Specialty Modules
Product Origin:
DE
Payment:
T/T, Western Union
Weight:
3.06g
Shipping port:
Xiamen
Warranty:
12 months


Share:

Description

2XV9450-1AR22 SICLOCK TM Central Clock (Industrial-Grade GPS Time Synchronization Server)

The Siemens 2XV9450-1AR22 delivers enterprise-level time synchronization for industrial control networks where millisecond-precision timing drives operational integrity. This rack-mountable GPS time server functions as the authoritative clock source for distributed automation systems, ensuring coordinated timestamping across SCADA platforms, DCS architectures, and networked instrumentation. Designed for power generation, process manufacturing, and critical infrastructure applications, it eliminates timing discrepancies that compromise sequence-of-events analysis, batch traceability, and regulatory compliance documentation.

Built to withstand harsh industrial environments, the SICLOCK TM operates reliably across -10°C to +55°C temperature ranges while maintaining ±1 millisecond accuracy through GPS satellite synchronization. Its wide-range 24-110V DC power input accommodates diverse facility electrical standards, while redundant time source capability ensures continuous operation during GPS signal interruptions. The 19-inch rack-mount form factor integrates seamlessly into control room infrastructure, providing centralized time distribution for hundreds of networked devices through standard Ethernet connectivity.

Whether you're upgrading legacy timing systems, implementing IEC 61850 substation automation, or establishing audit-compliant event logging for pharmaceutical manufacturing, this central clock delivers the precision and reliability demanded by mission-critical operations. Contact our technical team to configure the optimal synchronization architecture for your facility's specific requirements.

Core Capabilities & Technical Advantages

→ Multi-Protocol Time Distribution
Supports NTP, SNTP, and PTP (IEEE 1588) protocols simultaneously, enabling synchronization of both IT infrastructure and operational technology (OT) devices from a single source. Serves as authoritative Stratum 1 NTP server for enterprise networks while providing precision timing to automation controllers.

✓ Redundant Synchronization Sources
Primary GPS receiver with automatic failover to DCF77 radio signal, IRIG-B time code input, or network-based NTP sources. High-stability TCXO oscillator maintains ±0.5 second/day accuracy during extended outages, preventing time drift in GPS-denied environments.

→ Wide-Range Industrial Power Supply
24-110V DC input voltage range eliminates need for dedicated power conditioning, directly interfacing with standard control panel power rails. Reduces installation complexity and improves system reliability through native DC operation.

✓ Comprehensive Network Security
Implements authenticated NTP (NTPsec) to prevent time manipulation attacks, configurable access control lists (ACLs) for client filtering, and VLAN segmentation support. Meets cybersecurity requirements for IEC 62443 industrial network protection standards.

→ Intuitive Status Monitoring
Backlit LCD display provides real-time synchronization status, satellite lock indicators, and alarm conditions. SNMP trap generation enables integration with plant-wide monitoring systems for proactive maintenance alerting.

✓ Scalable Client Capacity
Handles 500+ simultaneous NTP client connections without performance degradation, supporting large-scale automation networks. Configurable update rates balance network bandwidth with synchronization precision requirements.

Industrial Application Scenarios

Power Generation & Transmission
Substations and generating facilities require microsecond-accurate timestamps for protective relay coordination, fault recorder synchronization, and synchrophasor measurement units (PMUs). The SICLOCK TM provides IEC 61850-compliant timing for digital substations, enabling accurate sequence-of-events recording during grid disturbances. Utility operators use synchronized data to analyze cascading failures, optimize breaker coordination, and meet NERC CIP regulatory requirements for event reconstruction.

Process Manufacturing & Batch Control
Pharmaceutical, chemical, and food processing plants depend on precise time synchronization for batch record integrity and FDA 21 CFR Part 11 compliance. The central clock ensures all DCS controllers, recipe management systems, and quality control instruments share identical timestamps, enabling accurate correlation of process parameters with production events. Eliminates timing discrepancies that invalidate batch documentation during regulatory audits.

Oil & Gas SCADA Networks
Pipeline monitoring systems and offshore platforms operate in GPS-challenged environments where reliable time synchronization prevents data correlation errors. The SICLOCK TM's holdover capability maintains accuracy during temporary satellite signal loss, while IRIG-B input accepts timing from platform navigation systems. Synchronized RTU polling ensures accurate leak detection through pressure wave analysis and flow balance calculations.

Transportation Infrastructure
Railway signaling systems, airport ground control, and traffic management networks require coordinated timing for safety-critical interlocking logic. The central clock synchronizes wayside controllers, centralized traffic control (CTC) systems, and communication-based train control (CBTC) networks, ensuring deterministic response to track occupancy changes and signal aspect transitions.

Data Center & Telecom Facilities
Carrier-grade timing for network equipment, billing systems, and log file correlation. Provides Stratum 1 accuracy for cellular base stations, VoIP gateways, and financial transaction processing where regulatory requirements mandate traceable time sources.

Technical Specifications & Selection Guide

ParameterSpecification
Model Number2XV9450-1AR22
Time Accuracy±1 millisecond (GPS locked)
Holdover Accuracy±0.5 seconds/day (GPS outage)
Synchronization InputsGPS L1, DCF77, IRIG-B (optional), NTP client
Time Distribution ProtocolsNTP v4, SNTP, PTP (IEEE 1588)
Network InterfaceEthernet 10/100 Mbps, RJ45
Power Supply24-110V DC (wide-range input)
Power Consumption15W typical, 25W maximum
Operating Temperature-10°C to +55°C
Storage Temperature-40°C to +70°C
Humidity5-95% RH (non-condensing)
Mounting19-inch rack, 3U height (133mm)
Dimensions (W×H×D)483 × 133 × 280 mm
Weight3.06 kg
DisplayLCD backlit, multi-line status
Alarm OutputsRelay contacts for sync loss
Configuration InterfaceWeb browser, SNMP, serial console
CertificationsCE, UL, IEC 61850 compliant

Selection Criteria: Choose the 2XV9450-1AR22 when your facility requires Stratum 1 time accuracy for regulatory compliance, operates in environments with existing 24-110V DC power infrastructure, or needs to synchronize mixed IT/OT networks through a single authoritative source. For applications requiring sub-microsecond precision (financial trading, scientific research), consider upgrading to PTP grandmaster clock solutions. Facilities with AC-only power should evaluate AC-powered SICLOCK variants or implement DC power supply modules.

Advanced Integration Features

SIMATIC Ecosystem Compatibility
Native integration with Siemens S7-300/400/1200/1500 PLCs through PROFINET time synchronization. Automatically discovered by TIA Portal engineering software, enabling drag-and-drop configuration of time-stamped data blocks and synchronized motion control sequences.

Automatic DST & Time Zone Management
Configurable daylight saving time rules for global deployments, supporting multiple time zones simultaneously. Eliminates manual clock adjustments during seasonal transitions, preventing production disruptions caused by timestamp discontinuities.

Firmware Update Capability
Field-upgradable firmware via Ethernet interface ensures long-term protocol compatibility as industrial standards evolve. Supports remote updates for geographically distributed installations, reducing maintenance travel costs.

Redundant Clock Architectures
Deploy multiple SICLOCK TM units in master-backup configurations for fault-tolerant timing. Automatic failover logic ensures seamless transition during primary clock failures, maintaining network synchronization without operator intervention.

Delivery Timeline & Service Commitment

Standard Lead Time: 3-5 business days for in-stock units; custom configurations requiring specific firmware versions or accessory bundles ship within 7-10 business days.

Warranty Coverage: 12-month manufacturer warranty covering defects in materials and workmanship. Extended warranty programs available for critical infrastructure applications requiring guaranteed replacement timelines.

Technical Support: Pre-sales engineering assistance for network architecture planning, GPS antenna placement optimization, and protocol compatibility verification. Post-installation support includes configuration troubleshooting, firmware update guidance, and performance optimization recommendations.

Documentation Package: Includes installation manual, quick-start guide, network integration examples, and configuration templates for common SCADA/DCS platforms. CAD drawings and mounting templates provided for mechanical integration planning.

Frequently Asked Questions

How does the GPS antenna installation affect time synchronization accuracy?
Antenna placement with clear sky visibility to at least 4 satellites is critical for maintaining ±1ms accuracy. Rooftop installations with minimal obstructions provide optimal performance. The system includes a 20-meter antenna cable; longer runs require active GPS repeaters to prevent signal degradation. Our technical team provides site survey assistance to identify optimal antenna locations.

Can this time server synchronize legacy serial-based automation equipment?
Yes, optional serial output modules (ordered separately) provide RS-232/RS-485 interfaces supporting ASCII time strings, IRIG-B modulated/unmodulated formats, and proprietary protocols for legacy DCS systems. Contact our sales team to specify required serial interface configurations during ordering.

What network bandwidth does NTP synchronization consume?
Typical NTP traffic averages 1-2 packets per client per minute, consuming negligible bandwidth (<1 kbps per client). Even networks with 500 synchronized devices experience <500 kbps aggregate NTP traffic, making the SICLOCK TM suitable for bandwidth-constrained industrial networks.

How does the system handle GPS jamming or spoofing attacks?
The SICLOCK TM monitors satellite signal quality and cross-validates GPS time against internal oscillator drift rates. Sudden time jumps exceeding configurable thresholds trigger alarms and prevent erroneous time distribution. For high-security applications, configure DCF77 or IRIG-B as independent validation sources to detect GPS anomalies.

Is the unit compatible with Precision Time Protocol (PTP) for motion control applications?
The 2XV9450-1AR22 supports PTP (IEEE 1588) as a boundary clock, providing sub-millisecond synchronization for distributed motion controllers and vision systems. For applications requiring sub-microsecond precision (coordinated multi-axis robotics), consider dedicated PTP grandmaster clocks optimized for transparent clock topologies.

What cybersecurity measures protect against unauthorized time manipulation?
Implemented security features include NTP authentication using symmetric key cryptography, MAC address filtering, IP-based access control lists, and VLAN tagging support. Disable unused protocols (SNMP, Telnet) and enable HTTPS-only web access to minimize attack surface. Regular firmware updates address emerging vulnerabilities.

Get Precision Timing for Your Facility

Eliminate timing discrepancies that compromise operational data integrity and regulatory compliance. Our industrial automation specialists will assess your facility's synchronization requirements, recommend optimal GPS antenna placement, and configure network protocols to match your existing infrastructure. Request a technical consultation to discuss your specific application requirements, or place your order now for fast delivery of the 2XV9450-1AR22 SICLOCK TM Central Clock.

Contact our team: Share your network architecture details, required synchronization accuracy, and environmental constraints to receive customized integration recommendations and competitive pricing for multi-unit deployments.


© 2026 NINERMAS COMPANY LIMITED. All rights reserved.
Original Source: https://ninermas.com
Contact: sale@ninermas.com | +0086 187 5021 5667

Related products