Original Industrial Spare Part

MKS DA01A12TGAS20A00 Service-Ready Spare Part for Industrial Maintenance

Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.

SKU: DA01A12TGAS20A00 CP4010, FC-226-02 2709-75313 13190869 EVS9322-ES TSI & Rotating Machinery Monitoring MKS Instruments

RFQ Ready

Pricing by RFQ

How Buyers Usually Use This Page

  • Confirm the exact part number and platform family before sending the quote request.
  • Use direct email when quantity, condition, and destination are already defined internally.
  • Switch to the broader brand or category archive when you need alternates nearby.

Series Navigation

Move through the most common platform families behind this part.

MKS DA01A12TGAS20A00 Service-Ready Spare Part for Industrial Maintenance

The MKS DA01A12TGAS20A00 is a Baratron absolute capacitance manometer designed for precision vacuum and pressure measurement in semiconductor fabrication, chemical vapor deposition (CVD), etch, and industrial process control environments. As a service-ready spare part, this unit is sourced, inspected, and pre-shipment tested to original MKS Instruments specifications, ensuring drop-in compatibility with existing process chambers, vacuum systems, and control architectures. For maintenance engineers managing aging process equipment or procurement teams building strategic spare parts inventories, the DA01A12TGAS20A00 represents a critical line-replaceable unit (LRU) that directly impacts mean time to repair (MTTR) and production uptime.

Unplanned downtime caused by a failed pressure transducer can cascade across an entire process line. The DA01A12TGAS20A00 is engineered for environments where measurement accuracy, long-term stability, and fast field replacement are non-negotiable. Whether you are performing a scheduled annual overhaul, responding to an emergency shutdown, or building a proactive spare parts buffer, having a verified, tested replacement unit on hand is the most effective risk mitigation strategy available to operations and maintenance teams.

Spare Maintenance Table

Parameter Specification
Part Number / SKU DA01A12TGAS20A00
Brand MKS Instruments
Series Baratron Type DA01A
Product Type Absolute Capacitance Manometer (Pressure Transducer)
Measurement Range 0 – 1 Torr (absolute, inferred from model code)
Output Signal Analog voltage (0–10 VDC, model-dependent)
Process Connection NW16 / KF16 flange (model-dependent)
Operating Temperature Ambient: 15–40°C; Sensor head: up to 45°C
Power Supply Requirement ±15 VDC or 24 VDC (via MKS PDR900 or compatible controller)
Compatibility MKS 937A, PDR900, 670 Signal Conditioner; standard analog I/O modules
Application Environment Semiconductor fab, CVD, PVD, etch, vacuum furnace, industrial process control
Installation Direct flange mount; no process interruption adapter required for same-series swap
Maintenance Interval Inspect annually; replace on drift >0.5% FS or zero-offset failure
Origin USA (MKS Instruments, Andover MA)
Warranty 12 Months from shipment date
Pre-Shipment Testing Yes – functional and calibration verification prior to dispatch
Long-Term Supply Reserved inventory available; contact for volume commitments

Maintenance Planning for Continuous Operation

Replacing the DA01A12TGAS20A00 in a live process environment is rarely an isolated task. Maintenance engineers conducting a thorough inspection of the associated vacuum or process control circuit should simultaneously evaluate the condition and calibration status of the MKS PDR900 or MKS 937A signal conditioner that powers and reads the transducer output. A degraded power supply rail — particularly the ±15 VDC supply feeding the Baratron — is a common root cause of apparent transducer drift and should be verified with a calibrated multimeter before condemning the sensor itself.

Within the same control cabinet or process module, the MKS FC-226-02 mass flow controller and MKS CP4010 power supply unit are frequently co-located with the DA01A12TGAS20A00 in CVD and etch tool configurations. If the pressure transducer has failed due to process contamination or overpressure, the upstream MKS 1179A or equivalent thermal mass flow controller should be inspected for internal contamination or valve seat wear. Signal wiring between the transducer and the analog input card of the host PLC or DCS should be checked for shielding integrity and ground loops, which can introduce noise that mimics sensor failure.

For facilities running legacy semiconductor or industrial vacuum equipment, the following components are commonly included in the same preventive maintenance (PM) cycle as the DA01A12TGAS20A00: analog signal isolators (for 0–10 V or 4–20 mA loops), 24 VDC DIN-rail power supplies feeding the I/O rack, terminal block assemblies and wiring harnesses at the transducer junction box, RS-232 or RS-485 communication modules if the system uses digital readout via MKS 670 or equivalent, and KF16/NW16 centering rings and O-rings at the process flange. Replacing these consumable interface components during the same maintenance window eliminates the risk of a secondary failure shortly after the primary repair, which is a leading cause of repeat unplanned downtime.

Procurement engineers building a spare parts inventory for multi-tool facilities should consider stocking the DA01A12TGAS20A00 alongside the MKS 627D Baratron (a common alternative range variant) and the MKS Type 722B dual-range transducer, which covers overlapping pressure measurement applications. Maintaining at least one unit of each critical transducer model in a climate-controlled, ESD-safe storage environment reduces emergency procurement lead times from weeks to hours.

Site Replacement Workflow

The DA01A12TGAS20A00 is designed as a direct replacement for earlier Baratron DA01A-series units. The replacement workflow for field engineers is as follows:

Step 1 – Isolation: Vent the process chamber to atmosphere or isolate the measurement port using the upstream gate valve. Confirm zero pressure at the transducer port using a secondary gauge before disconnecting.

Step 2 – Electrical Disconnect: Power down the MKS PDR900 or host signal conditioner. Disconnect the transducer cable at the D-sub or M12 connector. Label the cable with the port designation before removal to prevent reconnection errors in multi-transducer systems.

Step 3 – Mechanical Removal: Unbolt the KF16 clamp and remove the centering ring. Inspect the O-ring and flange face for contamination or damage. Replace the centering ring and O-ring as a matter of course — these are low-cost consumables that should never be reused after a transducer swap.

Step 4 – Installation: Mount the DA01A12TGAS20A00 replacement unit. Torque the KF clamp to specification. Reconnect the signal cable. Power up the signal conditioner and allow a 30-minute warm-up period before taking process measurements, as Baratron capacitance manometers require thermal stabilization to achieve rated accuracy.

Step 5 – Verification: Perform a zero-point calibration at base vacuum (<1×10⁻³ Torr) and a span check at a known reference pressure. Log the calibration data in the equipment maintenance record. Resume process operations only after the transducer output is confirmed stable within ±0.25% FS.

This workflow minimizes system downtime to under two hours for a trained technician, supporting MTTR targets of 4–6 hours for the broader process tool recovery.

Spare Parts Support FAQ

Q1: Is the DA01A12TGAS20A00 a new or refurbished unit?
All units supplied by NINERMAS are sourced from verified supply channels and undergo pre-shipment functional and calibration testing. Unit condition (new, surplus-new, or refurbished-to-spec) is confirmed at the time of order. Each unit is covered by a 12-month warranty from the shipment date, regardless of condition grade.

Q2: How do I confirm compatibility with my existing MKS signal conditioner or controller?
The DA01A12TGAS20A00 is compatible with MKS PDR900, 937A, and 670-series signal conditioners that accept a standard Baratron analog output. Verify the power supply voltage (±15 VDC or 24 VDC) and connector type (D-sub 15-pin or M12) against your existing cable harness before ordering. Our technical team can assist with compatibility verification based on your tool model and process configuration.

Q3: What is the lead time, and do you hold reserved inventory?
Standard lead time for the DA01A12TGAS20A00 is 3–7 business days from order confirmation. Reserved inventory programs are available for facilities requiring guaranteed stock levels for critical spare parts. Contact our sales team to discuss volume commitments and long-term supply agreements that align with your annual maintenance schedule.

Q4: What documentation is provided with the shipment?
Each unit ships with a pre-shipment test report confirming functional verification, a packing list, and a 12-month warranty certificate. Calibration certificates traceable to national standards are available upon request for facilities with ISO or SEMI compliance requirements. All documentation is provided in English.

Product Series

Other series

Catalog Continuation

More MKS Instruments modules in the catalog.

Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.

Open this lane

Catalog Continuation

Alternative parts within TSI & Rotating Machinery Monitoring.

Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.

Open this lane

Industrial RFQ Support

Need a fast quote for a specific part number or system family?

Send your inquiry with brand, series, quantity, condition, and destination details. We will follow up on availability, lead time, and shipping options.

CallPhone MailEmail WAChat TopBack