(0 reviews)
Manufacturer:
GE
Product No.:
URSHA
Condition:
1000 in stock
Product Type:
Multilin
Product Origin:
US
Payment:
T/T, Western Union
Weight:
1.00g
Shipping port:
Xiamen
Warranty:
12 months


Share:

Description

URSHA Industrial Power Module (High-Performance DC Supply for GE UR Protection Systems)

The URSHA represents General Electric's premium power solution engineered specifically for Universal Relay Series protection platforms. This industrial-grade module delivers consistent, high-capacity DC power to mission-critical relay systems operating in substations, generation facilities, and heavy industrial environments where power reliability directly impacts operational safety and continuity.

Designed for protection engineers and facility managers overseeing electrical infrastructure, the URSHA addresses the fundamental challenge of maintaining stable power delivery to sophisticated protection devices under extreme environmental conditions. When standard power supplies fail due to temperature fluctuations, voltage transients, or electromagnetic interference, critical protection systems go offline—creating dangerous exposure to equipment damage and unplanned outages.

This module eliminates power-related vulnerabilities through military-grade component selection, advanced thermal management, and comprehensive input protection circuitry. The result: protection relays that remain operational through the harshest conditions, backed by over 200,000 hours mean time between failures and field-proven performance across thousands of installations worldwide.

Core Capabilities & Business Impact

→ Dual-Voltage Architecture (125/250V DC)
Single module supports both voltage standards, eliminating inventory complexity and enabling rapid deployment across mixed-voltage facilities. Reduces spare parts requirements by 50% compared to single-voltage alternatives.

✓ Extended Temperature Performance (-40°C to +85°C)
Maintains full output capacity across 125°C temperature span without derating. Proven operation in Arctic substations and desert solar farms where conventional supplies require climate control or frequent replacement.

✓ Hot-Swap Serviceability
Field-replaceable during live operation without relay shutdown or protection scheme interruption. Typical maintenance window: under 3 minutes versus 2+ hours for non-modular systems.

✓ EMI/RFI Hardened Design
Military-standard filtering protects against switching transients, radio frequency interference, and conducted emissions common in high-voltage switchgear environments. Meets IEC 61000-4 immunity requirements with 40% margin.

✓ Diagnostic LED Array
Real-time status indication for input voltage, output regulation, thermal condition, and fault states. Reduces troubleshooting time by 70% through instant visual feedback.

✓ Redundancy-Ready Configuration
Native support for N+1 parallel operation with automatic load sharing and seamless failover. Critical for applications requiring 99.999% availability (5.26 minutes annual downtime).

Industry Applications & Problem Resolution

Transmission Substation Protection
Powers line differential, distance, and breaker failure relays protecting 115kV-765kV circuits. Solves the challenge of maintaining protection during battery system maintenance or DC bus disturbances. Typical deployment: 4-8 modules per substation supporting 12-24 protection devices.

Generator Protection & Control
Enables continuous operation of generator differential, reverse power, and synchronization relays in combined-cycle plants and renewable facilities. Addresses power quality issues from variable-speed drives and inverter-based generation that disrupt conventional supplies.

Industrial Motor Protection Networks
Supports distributed motor management systems in mining, petrochemical, and manufacturing facilities where process interruption costs exceed $50,000/hour. Withstands vibration, dust, and corrosive atmospheres that degrade standard power modules within 18-24 months.

Distribution Automation Systems
Provides stable power for recloser controls, capacitor bank controllers, and SCADA RTUs in outdoor pad-mounted installations. Eliminates failures caused by solar heating (internal temperatures exceeding 70°C) and winter cold-soaking.

Renewable Energy Integration
Powers protection relays managing solar inverter arrays and wind turbine collector systems. Handles rapid voltage fluctuations and harmonic distortion inherent to inverter-dominated grids that cause nuisance trips in legacy power supplies.

Technical Parameters & Selection Criteria

SpecificationValueSelection Notes
Input Voltage125/250V DC ±20%Auto-sensing; no jumper configuration required
Output PowerHigh-capacity ratingSupports full UR chassis with maximum I/O expansion
Efficiency>88% typicalReduces heat generation and cooling requirements
Isolation2.5kV input-to-outputProtects against ground potential rise during faults
Hold-Up Time50ms minimumRides through momentary DC bus interruptions
MTBF>200,000 hoursCalculated per MIL-HDBK-217F at 40°C ambient
DimensionsModular UR slotOccupies single slot in UR chassis
CertificationsUL, CE, IEC 61010Meets North American and international standards

Selection Guidelines: Choose URSHA for applications requiring maximum power capacity, dual-voltage flexibility, or operation beyond standard industrial temperature ranges. For lower-power applications or single-voltage installations, consider alternative UR power modules. Consult factory specifications to match module capacity with total chassis load including all installed I/O and communication modules.

Advanced Integration Features

Parallel Redundancy Operation: Deploy multiple URSHA modules in load-sharing configuration for critical applications. Each module operates independently with automatic current balancing—if one module fails, remaining units instantly assume full load without relay interruption or alarm generation.

Remote Monitoring Compatibility: Status outputs integrate with SCADA systems and building management platforms for centralized power system monitoring. Enable predictive maintenance by tracking temperature trends, input voltage variations, and load current over time.

Custom Voltage Configurations: Factory customization available for non-standard DC bus voltages (48V, 110V, 220V) in quantities of 10+ units. Consult technical support for lead times and minimum order requirements.

Delivery Timeline & Service Commitment

Standard Delivery: 3-5 business days for in-stock modules to major industrial centers; 7-10 days for remote locations. Expedited shipping available for emergency replacements.

Custom Configurations: 4-6 weeks for factory-modified voltage ratings or extended temperature variants.

Warranty Coverage: 12-month comprehensive warranty covering manufacturing defects, component failures, and performance degradation. Extended warranty programs available for critical infrastructure applications.

Technical Support: Direct access to application engineers with GE UR platform expertise. Support includes module selection, redundancy design, troubleshooting assistance, and integration guidance.

Documentation Package: Complete installation manual, dimensional drawings, terminal connection diagrams, and compliance certificates included with every shipment.

Frequently Asked Questions

How does the URSHA module handle input voltage transients during switching operations?
The module incorporates surge suppression rated for IEEE C62.41 Category B transients (6kV/3kA) commonly encountered during breaker operations and capacitor switching. Internal protection circuitry clamps transients within 1 microsecond, preventing damage to downstream relay electronics.

What is the maximum ambient temperature for continuous operation at full load?
The URSHA maintains rated output up to +85°C ambient without forced cooling or derating. Above 85°C, automatic thermal foldback reduces output current to prevent component stress. For sustained operation above 70°C, verify adequate chassis ventilation and consider redundant module configuration.

Can I mix URSHA modules with other UR power supply variants in the same chassis?
Yes, the UR architecture supports mixed power module configurations. However, for redundant operation, use identical module types to ensure matched current sharing characteristics. Mixing different power ratings may result in uneven load distribution.

What installation clearances are required for proper thermal performance?
Maintain minimum 50mm (2 inches) clearance above and below the chassis for natural convection cooling. In enclosed panels, provide forced ventilation if ambient temperature exceeds 55°C or if multiple high-power modules are installed in adjacent slots.

Does the module support remote on/off control for energy management applications?
The URSHA operates continuously when input power is present—it does not include remote enable/disable functionality. For applications requiring power sequencing, implement control at the DC distribution level using contactors or circuit breakers.

How do I verify proper module operation during commissioning?
Observe the green LED indicator for steady illumination confirming normal operation. Measure output voltage at relay terminals (should be within ±2% of nominal). Check input current draw against module specifications—excessive current may indicate downstream short circuit or overload condition.

Order Your URSHA Power Module Today

Ensure uninterrupted protection system operation with genuine GE URSHA power modules. Contact our technical sales team for application-specific recommendations, volume pricing, or integration support. Immediate stock availability for standard configurations—order before 2 PM for same-day shipment.

Need assistance with module selection or system design? Our protection system specialists are available to review your application requirements and recommend optimal power architecture for your facility.


© 2026 NINERMAS COMPANY LIMITED. All rights reserved.
Original Source: https://ninermas.com
Contact: sale@ninermas.com | +0086 187 5021 5667

Related products