Description

GE IC200ETM001 VersaMax Ethernet Communication Module (Industrial TCP/IP Interface Solution)

The GE IC200ETM001 is a high-performance Ethernet communication module designed for VersaMax PLC systems, enabling seamless TCP/IP connectivity in industrial automation environments. Through advanced 10/100 Mbps Ethernet technology and Modbus TCP protocol support, this module delivers reliable real-time data exchange, remote monitoring capabilities, and enterprise-level network integration.

Ideal for manufacturing facilities, process control systems, SCADA networks, and distributed automation architectures, the IC200ETM001 addresses critical challenges including isolated legacy systems, limited remote access, slow data acquisition, and complex multi-site coordination requirements.

Featuring standardized design with flexible configuration options, this module offers plug-and-play installation, robust industrial-grade construction, superior electromagnetic compatibility, and comprehensive diagnostic capabilities—making it the preferred choice for system integrators, automation engineers, OEM equipment manufacturers, and plant maintenance teams. Contact our technical specialists for customized integration solutions and competitive quotations.

Core Features & Technical Advantages

High-Speed Ethernet Connectivity
Equipped with 10/100 Mbps auto-negotiating Ethernet port with RJ45 interface, supporting full-duplex communication for maximum throughput and minimal latency in time-critical industrial applications.

Multi-Protocol Support
Native Modbus TCP/IP server and client functionality, plus support for SRTP (Service Request Transport Protocol) and EGD (Ethernet Global Data) for versatile integration with diverse automation ecosystems.

Seamless VersaMax Integration
Hot-swappable design allows installation and removal without system shutdown, automatic configuration recognition, and unified programming environment through GE Proficy Machine Edition software.

Industrial-Grade Reliability
Conformal-coated PCB for harsh environment protection, -20°C to +60°C operating temperature range, 1500V DC isolation between Ethernet and backplane, and MTBF exceeding 500,000 hours.

Advanced Diagnostic Capabilities
Integrated LED status indicators for power, link activity, and communication health; web-based configuration interface; SNMP support for network management; and detailed error logging for rapid troubleshooting.

Scalable Architecture
Supports up to 32 simultaneous TCP connections, 256 Modbus TCP devices, and multiple subnet configurations, enabling expansion from single-machine control to plant-wide automation networks.

Typical Application Scenarios

This module excels in environments demanding stable network connectivity, continuous data availability, and seamless integration with enterprise IT infrastructure:

Manufacturing Execution Systems (MES)
Bridges shop-floor PLCs with upper-level MES platforms, enabling real-time production tracking, quality data collection, and OEE calculation for lean manufacturing initiatives.

Remote SCADA & HMI Access
Facilitates secure remote monitoring and control of distributed assets across multiple sites, reducing on-site visits while maintaining full operational visibility and alarm management.

Process Industry Automation
Integrates with DCS systems in chemical, pharmaceutical, and food processing plants, supporting recipe management, batch control, and regulatory compliance data logging.

Building & Infrastructure Control
Connects HVAC, lighting, and energy management systems to centralized building automation networks, optimizing energy consumption and occupant comfort.

OEM Machine Builders
Embedded in packaging machinery, material handling equipment, and specialized production lines, providing standardized connectivity for end-user integration and remote service capabilities.

Technical Specifications & Selection Guide

To ensure optimal performance and compatibility, please review the following technical parameters:

Electrical Specifications

  • Power Supply: 5V DC from VersaMax backplane (150 mA typical)
  • Isolation: 1500V DC between Ethernet and logic circuits
  • Power Consumption: 0.75W maximum

Network Interface

  • Connector: RJ45 female, shielded
  • Speed: 10/100 Mbps auto-negotiation
  • Duplex: Full/half-duplex auto-sensing
  • Cable: Cat5e or better, up to 100m segment length

Protocol Support

  • Modbus TCP (server/client, up to 256 devices)
  • SRTP (Service Request Transport Protocol)
  • EGD (Ethernet Global Data exchange)
  • SNMP v1/v2c for network management

Environmental Ratings

  • Operating Temperature: -20°C to +60°C (-4°F to +140°F)
  • Storage Temperature: -40°C to +85°C (-40°F to +185°F)
  • Humidity: 5% to 95% non-condensing
  • Vibration: IEC 60068-2-6 compliant
  • Shock: IEC 60068-2-27 compliant

Physical Dimensions

  • Form Factor: Single-slot VersaMax module
  • Dimensions: 80mm (H) × 30mm (W) × 91mm (D)
  • Weight: Approximately 120g
  • Mounting: DIN rail via VersaMax carrier

Selection Considerations
When specifying the IC200ETM001, consider: network topology (star/daisy-chain), required data throughput, number of concurrent connections, existing PLC configuration, cybersecurity requirements (firewall/VPN integration), and future expansion plans. Our application engineers can assist with network architecture design, IP addressing schemes, and performance optimization—simply provide your system overview, communication requirements, environmental conditions, and installation timeline.

Extended Functionality & Integration Options

Web-Based Configuration
Built-in HTTP server allows browser-based setup and diagnostics without specialized software, streamlining commissioning and maintenance workflows.

Email Notification Support
Configure SMTP client functionality to send alarm emails directly from the PLC, enabling proactive maintenance and rapid incident response.

FTP File Transfer
Automated program backup, recipe download, and data logging file retrieval via standard FTP protocol, simplifying version control and audit trail management.

Time Synchronization
SNTP client ensures accurate timestamping across distributed systems, critical for event correlation and regulatory compliance in validated environments.

Cybersecurity Features
MAC address filtering, port-based access control, and encrypted communication options (when paired with industrial firewalls) protect against unauthorized access and cyber threats.

Delivery, Service & Quality Assurance

Standard catalog items ship within 3-5 business days from our regional distribution centers; custom-configured modules or bulk orders typically require 7-14 days lead time. All products include a minimum 12-month manufacturer warranty covering defects in materials and workmanship.

Comprehensive technical support includes remote configuration assistance, on-site commissioning services (subject to location and project scope), and 24/7 emergency hotline access for critical applications. Each module ships with complete documentation package: installation quick-start guide, detailed user manual, wiring diagrams, Modbus register mapping, and sample ladder logic code for common integration tasks.

Our quality management system maintains ISO 9001 certification, and all products undergo rigorous factory acceptance testing including burn-in cycles, communication protocol verification, and environmental stress screening to ensure field-ready reliability.

Frequently Asked Questions (FAQ)

Q: How does the IC200ETM001 integrate with existing VersaMax PLC systems?
A: The module installs directly into any available slot on the VersaMax carrier, automatically recognized by the CPU upon power-up. Configuration is performed through GE Proficy Machine Edition software using intuitive drag-and-drop interface—no special programming required for basic Modbus TCP functionality.

Q: What is the maximum number of devices I can connect via Modbus TCP?
A: The IC200ETM001 supports up to 256 Modbus TCP slave devices as a master, and can handle 32 simultaneous TCP socket connections. Actual performance depends on data exchange frequency, message size, and network infrastructure quality.

Q: Can this module work with non-GE PLCs or SCADA systems?
A: Yes, through standard Modbus TCP protocol, the module communicates with any Modbus-compatible device regardless of manufacturer—including Siemens, Allen-Bradley, Schneider Electric controllers, and popular SCADA platforms like Wonderware, Ignition, and FactoryTalk.

Q: What cybersecurity measures should I implement when using Ethernet modules?
A: Best practices include: segregating industrial networks from corporate IT using VLANs or physical separation, deploying industrial firewalls with deep packet inspection, implementing MAC address whitelisting, disabling unused protocols/ports, regular firmware updates, and encrypted VPN tunnels for remote access.

Q: Does the module require special cabling or network switches?
A: Standard Cat5e/Cat6 Ethernet cables suffice for most installations. For industrial environments, use shielded cables and industrial-grade managed switches with IGMP snooping, QoS prioritization, and redundant power supplies to ensure network reliability and deterministic performance.

Q: How do I troubleshoot communication failures?
A: Start with LED diagnostics (power, link, activity indicators), verify IP configuration and subnet masks, check physical cable continuity, use ping tests to confirm network connectivity, review Modbus exception codes in PLC diagnostics, and consult the built-in web server for detailed error logs and connection statistics.

Request Technical Support & Quotation

For detailed application engineering support, custom integration solutions, or competitive project pricing, please provide the following information to our technical sales team:

  • Project name and application overview
  • Existing PLC platform and firmware version
  • Number of Ethernet modules required
  • Connected devices and communication protocols
  • Network architecture (topology, IP scheme, VLAN requirements)
  • Environmental conditions and installation location
  • Delivery timeline and budget constraints

Our certified automation specialists will respond within 24 hours with tailored recommendations, bill of materials, and implementation roadmap to ensure project success.

© 2026 NINERMAS COMPANY LIMITED. All rights reserved.
Original Source: https://ninermas.com
Contact: sale@ninermas.com | +0086 187 5021 5667

Related products