The GE IC200ERM002E is an industrial Ethernet communication module designed for seamless integration with VersaMax PAC systems. Through advanced TCP/IP protocol support and robust hardware architecture, it enables real-time data exchange, remote monitoring, and distributed control across industrial networks.
Ideal for manufacturing automation, process control, SCADA integration, and multi-site facility management scenarios, this module addresses challenges such as limited fieldbus connectivity, slow data transmission, complex protocol conversion, and inadequate remote diagnostics capabilities.
With standardized design and flexible configuration options, the IC200ERM002E delivers high-speed communication, industrial-grade reliability, simplified installation, and broad compatibility—making it the preferred choice for system integrators, automation engineers, OEM equipment manufacturers, and plant maintenance teams. Contact our engineering team for application-specific configuration guidance and technical quotations.
This module is engineered for applications requiring reliable network communication, real-time data visibility, and seamless integration with existing automation infrastructure, particularly in:
To ensure optimal performance and compatibility, we offer detailed technical parameters and configuration options. Custom solutions are available based on specific project requirements.
| Parameter | Specification |
|---|---|
| Network Interface | 10/100BASE-T Ethernet, RJ45 connector |
| Supported Protocols | TCP/IP, UDP, Modbus TCP, EGD, SRTP |
| Communication Speed | 10/100 Mbps auto-negotiation |
| Power Consumption | Typical 3.5W @ 24VDC |
| Operating Temperature | -40°C to +70°C (-40°F to +158°F) |
| Storage Temperature | -40°C to +85°C (-40°F to +185°F) |
| Humidity Range | 5% to 95% non-condensing |
| Vibration Resistance | IEC 60068-2-6 compliant |
| Shock Resistance | IEC 60068-2-27 compliant |
| EMC Compliance | CE, UL, cUL, RCM certified |
| Protection Rating | IP20 (when properly installed) |
| Mounting | DIN rail or panel mount compatible |
| Dimensions (H×W×D) | 118 mm × 35 mm × 114 mm |
Selection Recommendations: When specifying this module, consider network topology requirements, data throughput demands, environmental conditions, power supply availability, and integration with existing control platforms. For assistance with system architecture design or protocol configuration, please provide your application details—our engineering team will recommend the optimal configuration and supporting components.
Standard catalog items ship from stock within 2-5 business days; custom-configured solutions typically require 10-15 business days lead time. All modules include a minimum 12-month manufacturer warranty covering defects in materials and workmanship.
Comprehensive technical support includes remote configuration assistance, on-site commissioning services (region-dependent), and access to detailed documentation including wiring diagrams, protocol specifications, and troubleshooting guides. Complete installation manuals, configuration software, and sample code libraries are provided with each shipment to streamline deployment and maintenance.
Q: How does the IC200ERM002E Ethernet module integrate with existing VersaMax systems?
A: The module features hot-swappable installation into any VersaMax expansion rack. Simply insert the module into an available slot, configure the IP address via DIP switches or software, and establish network connectivity—no controller restart required for most configurations.
Q: What is the maximum network distance supported by this Ethernet module?
A: Standard Cat5e/Cat6 cabling supports up to 100 meters (328 feet) between the module and network switch. For extended distances, use fiber optic media converters or industrial Ethernet switches with fiber uplinks.
Q: Can this module communicate with non-GE controllers or third-party devices?
A: Yes, the IC200ERM002E supports industry-standard protocols including Modbus TCP and generic TCP/IP sockets, enabling communication with PLCs, HMIs, and SCADA systems from multiple manufacturers.
Q: What cybersecurity features are included to protect industrial networks?
A: The module supports IP address filtering, MAC address whitelisting, and configurable port access controls. For enhanced security, deploy within a segmented industrial network with firewall protection and regular firmware updates.
Q: Is remote monitoring and diagnostics possible with this Ethernet module?
A: Absolutely. The built-in web server provides real-time status monitoring, diagnostic logs, and configuration access via any standard web browser. Integration with SCADA or MES platforms enables centralized monitoring across multiple sites.
Q: What environmental conditions can the IC200ERM002E withstand?
A: The module is rated for -40°C to +70°C operation with conformal coating protection against moisture and contaminants. It meets industrial vibration and shock standards, making it suitable for factory floor, outdoor enclosures, and mobile equipment installations.
For detailed application engineering, custom configuration assistance, or project quotations, please provide the following information: project name, application type, network architecture requirements, quantity needed, environmental conditions, and integration platform details. Our technical team will respond with tailored recommendations and competitive pricing within 24 hours.