The Bachmann DI016-C❄ represents a breakthrough in extreme-environment automation technology, delivering 16 fully configurable digital I/O channels with proven reliability in temperatures ranging from -40°C to +70°C. Engineered for mission-critical applications in oil & gas, mining, cold storage, and outdoor infrastructure, this stand-alone CAN slave module eliminates the need for heated enclosures while maintaining industrial-grade performance standards.
Built on Bachmann's proven M1 system architecture, the DI016-C❄ combines CANopen DS401 device profile compliance with 500V galvanic isolation and 1A continuous output current per channel. Whether you're retrofitting legacy systems or designing new installations, this module delivers the flexibility to configure channels as inputs or outputs on-the-fly, reducing inventory complexity and installation time by up to 40%.
With dual internally-connected CAN interfaces for daisy-chain topology, rotary-switch configuration for baud rate and node ID, and EN 50022 DIN rail mounting, the DI016-C❄ integrates seamlessly into distributed control architectures. Request technical specifications and application notes today to discover how this cold-climate solution can enhance your system reliability.
→ Extreme Temperature Operation: Certified for -40°C to +70°C ambient conditions without auxiliary heating or forced cooling, reducing enclosure costs and energy consumption by eliminating climate control requirements in outdoor installations.
→ Flexible Channel Configuration: All 16 channels freely programmable as inputs or outputs via CANopen object dictionary, enabling rapid field modifications without hardware changes—ideal for evolving process requirements and standardized spare parts inventory.
→ Robust Output Design: Each output channel delivers 1A continuous current with short-circuit protection and 12A total block capacity, supporting direct actuation of solenoid valves, indicator lights, and relay coils without external amplification.
→ Dual CAN Interface Architecture: Two 9-pin D-Sub connectors with internal loop-through enable linear or star network topologies, simplifying cable routing and providing redundancy options for critical control loops.
→ Galvanic Isolation Protection: 500V isolation between CAN bus and I/O circuits prevents ground loop interference and protects upstream controllers from field-side electrical faults, enhancing system-wide reliability.
→ Tool-Free Configuration: Rotary switches for baud rate (10 Kbaud to 1 Mbaud) and node ID (1-254) eliminate the need for programming devices during commissioning, reducing startup time and technician skill requirements.
✓ Oil & Gas Wellhead Monitoring: Monitor valve positions, pressure switches, and flow sensors in unheated wellhead enclosures across Arctic and desert environments. The cold-climate rating eliminates heater failures that cause 30% of remote site downtime, while CANopen integration enables centralized SCADA visibility.
✓ Cold Storage & Refrigeration Control: Control defrost cycles, door interlocks, and alarm indicators inside -40°C freezer rooms without temperature-sensitive electronics degradation. Configurable I/O allows single module type to handle both input sensing and output control, reducing spare parts inventory.
✓ Mining Conveyor Systems: Interface with emergency stop circuits, belt alignment sensors, and motor contactors in outdoor conveyor galleries exposed to temperature extremes. Galvanic isolation protects against lightning-induced surges common in exposed installations.
✓ Railway Signal & Switch Control: Operate trackside signals, point motors, and detection circuits in outdoor cabinets without climate control. Dual CAN interfaces support redundant communication paths required by safety-critical railway standards.
✓ Water Treatment Remote Stations: Monitor level sensors, control chemical dosing pumps, and manage alarm outputs at unmanned lift stations. Low power consumption (100mA typical) enables solar-powered installations with minimal battery capacity.
| Parameter | Specification | Selection Notes |
|---|---|---|
| I/O Channels | 16 configurable (input or output) | Choose DI016-C❄ for compact applications; DIO32-C/48-C/64-C available for higher density |
| Operating Temperature | -40°C to +70°C (Cold Climate ❄) | Standard DI016-C rated 0°C to +60°C; specify ❄ variant for extreme environments |
| Supply Voltage | 18-34 VDC (24 VDC nominal) | Compatible with standard industrial power supplies; reverse polarity protected |
| Output Current | 1A continuous per channel, 12A per block | Sufficient for most solenoids and relays; use external contactors for higher loads |
| Input Characteristics | 6 kΩ internal resistance, <3.5ms delay | Compatible with PNP/NPN sensors; response time suitable for most discrete control |
| CAN Protocol | CANopen DS301/DS401, CAL | Verify master controller supports DS401 device profile for plug-and-play integration |
| Baud Rate | 10 Kbaud to 1 Mbaud (rotary switch) | Match existing network speed; 250 Kbaud typical for industrial applications |
| Isolation Voltage | 500V (CAN to I/O) | Meets EN 61010-1 requirements for industrial control equipment |
| Mounting | EN 50022 DIN rail (35mm) | Standard rail mount; no backplane required—reduces panel space by 30% |
| Dimensions | Compact modular housing | Consult datasheet for exact dimensions; typically 22.5mm width per module |
Selection Guidelines: For applications requiring more than 16 I/O points, consider the DIO32-C (32 channels) or DIO48-C (48 channels) to reduce wiring complexity. If operating temperatures remain above 0°C, the standard DI016-C offers identical functionality at lower cost. For safety-critical applications, verify CANopen Safety (CiA 304) requirements—this module supports standard DS401 profile only.
CANopen Object Dictionary Customization: Bachmann provides EDS (Electronic Data Sheet) files for seamless integration with major PLC brands including Siemens, Rockwell, and Schneider Electric. Custom PDO (Process Data Object) mapping enables optimized network bandwidth utilization for high-speed applications.
M1 System Expansion: Combine with Bachmann analog I/O modules, motion controllers, and communication gateways to build complete distributed control systems. Single engineering toolchain (SolutionCenter) simplifies multi-module configuration and diagnostics.
Redundancy Configurations: Dual CAN interfaces support hot-standby controller architectures when paired with redundant CANopen masters. Consult application engineering for failover logic implementation.
Harsh Environment Accessories: Optional conformal coating (IEC 60721-3-3 Class 3C2) available for corrosive atmosphere protection. Locking D-Sub connectors prevent vibration-induced disconnection in mobile equipment.
Lead Time: Standard DI016-C❄ units ship within 2-3 weeks from order confirmation. Custom configurations (conformal coating, extended temperature testing) require 4-6 weeks. Expedited delivery available for critical projects—contact sales for options.
Warranty Coverage: 24-month manufacturer warranty covering defects in materials and workmanship. Extended warranty programs available for OEM integrators with annual volume commitments exceeding 50 units.
Technical Resources: Comprehensive documentation package includes installation manual, CANopen EDS file, wiring diagrams, and troubleshooting guide. Free access to Bachmann's online knowledge base with application notes, firmware updates, and video tutorials.
Engineering Support: Pre-sales application engineering assistance available via email and phone. Post-sales support includes configuration review, network diagnostics, and on-site commissioning services (fees apply for on-site visits).
Compliance Certifications: CE marked for EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU. UL/cUL listing available upon request. RoHS and REACH compliant for global market access.
Q: Can the DI016-C❄ operate as a CANopen master controller?
A: No, this module functions exclusively as a CANopen slave device (DS401 profile). It requires connection to a CANopen master such as a PLC, industrial PC, or dedicated motion controller. For master functionality, consider Bachmann's MC206 or MX220 controllers.
Q: What is the maximum cable distance between modules on the CAN network?
A: Maximum network length depends on baud rate: 1000m at 50 Kbaud, 500m at 125 Kbaud, 100m at 500 Kbaud, 40m at 1 Mbaud. Use repeaters or bridges for longer distances. Stub lengths from backbone to individual modules should not exceed 0.3m.
Q: How much power does the module consume, and can it be powered via the CAN bus?
A: The DI016-C❄ draws approximately 100mA at 24 VDC without I/O load, plus additional current for active outputs (up to 12A total). It requires separate 18-34 VDC power supply—CAN bus power (DeviceNet-style) is not supported. Use isolated DC/DC converters in multi-module installations.
Q: Are the input and output channels electrically isolated from each other?
A: Outputs are grouped into isolated blocks (configuration depends on model variant). Inputs share common ground. The CAN interface is isolated from all I/O circuits by 500V. Consult the datasheet for specific isolation topology—critical for applications with multiple ground references.
Q: Can I mix input and output functions on the same module simultaneously?
A: Yes, all 16 channels are individually configurable via CANopen object dictionary. You can assign any combination (e.g., 10 inputs + 6 outputs) and reconfigure in the field without hardware changes. Configuration persists through power cycles via non-volatile memory.
Q: What diagnostic capabilities does the module provide for troubleshooting?
A: Front-panel LEDs indicate RUN status (guarding active), INIT mode (startup sequence), and ERROR conditions (communication loss, overload). Individual channel LEDs show I/O state. CANopen emergency messages report specific fault codes to the master controller for remote diagnostics.
Ready to enhance your extreme-environment control system with proven cold-climate I/O technology? Our application engineers will review your specifications, recommend optimal configuration, and provide detailed pricing within 24 hours. Contact us today with your project requirements—include temperature range, I/O count, and communication protocol details for fastest response.
For existing Bachmann M1 system users: We offer trade-in credits on legacy modules when upgrading to cold-climate variants. Mention this offer when requesting your quote.
© 2026 NINERMAS COMPANY LIMITED. All rights reserved.
Original Source: https://ninermas.com
Contact: sale@ninermas.com | +0086 187 5021 5667
Download PDF file here:
Click to Download PDF