The Allen-Bradley 1785-LT/B PLC-5/15 Processor Module is a high-performance programmable logic controller designed for demanding industrial automation applications. Featuring 16K words of user memory and robust processing capabilities, this module delivers reliable control for discrete manufacturing, process automation, and integrated SCADA systems. Built on Allen-Bradley's proven PLC-5 architecture, it ensures seamless integration with existing Rockwell Automation ecosystems.
Ideal for manufacturing plants, process industries, material handling systems, and industrial OEMs, this processor module addresses critical challenges including system downtime, complex logic execution, legacy equipment integration, and real-time monitoring requirements. Whether you're upgrading aging control systems or maintaining mission-critical production lines, the 1785-LT/B delivers proven reliability.
With factory-calibrated OEM quality, comprehensive diagnostic capabilities, and backward compatibility with PLC-5 family components, this processor module offers exceptional value, proven durability, straightforward programming, and long-term availability. Suitable for design engineers, system integrators, maintenance teams, and plant managers seeking dependable automation solutions. Contact our technical team for application-specific configuration guidance and competitive quotations.
The Allen-Bradley 1785-LT/B processor module excels in applications requiring deterministic control, system reliability, and proven technology compatibility, particularly in:
To ensure optimal system performance and compatibility, the 1785-LT/B processor module offers the following specifications:
| Processor Type | PLC-5/15 |
| User Memory | 16K words (expandable with memory modules) |
| I/O Capacity | Up to 3,072 discrete I/O points |
| Scan Time | Typically 1-5 ms per K of logic (application dependent) |
| Communication Ports | DH+ and Remote I/O (via chassis backplane) |
| Power Requirements | 5V DC @ 1.5A (supplied by 1785 chassis) |
| Operating Temperature | 0°C to 60°C (32°F to 140°F) |
| Enclosure Rating | Open-type module (requires NEMA-rated chassis) |
| Programming Software | RSLogix 5 or RSLogix 500 (compatibility mode) |
| Mounting | 1785 chassis slot (any slot except slot 0) |
Selection Considerations: When specifying this processor, evaluate total I/O count requirements, communication network architecture, program complexity and memory needs, environmental conditions and enclosure ratings, and integration with existing Rockwell Automation components. For custom configurations or application-specific recommendations, provide your system requirements to our engineering team for tailored solution design.
Stock Availability: Standard catalog items ship within 1-3 business days; custom-configured systems require 5-10 business days lead time.
Warranty Coverage: All modules include a comprehensive 12-month warranty covering manufacturing defects and component failures under normal operating conditions.
Technical Support: Access to experienced automation engineers for application assistance, troubleshooting guidance, and system optimization recommendations (remote support standard; on-site services available by region).
Documentation Package: Complete technical data sheets, wiring diagrams, RSLogix 5 sample programs, and installation quick-start guides provided with every order to streamline commissioning and maintenance.
Quality Standards: Factory-tested OEM components meeting UL, CSA, and CE compliance requirements for industrial control equipment.
Q: How does the Allen-Bradley 1785-LT/B PLC-5/15 processor integrate with existing automation systems?
A: The 1785-LT/B is fully compatible with all Allen-Bradley 1785 chassis and I/O modules. It communicates via DH+ and Remote I/O networks, and can interface with modern Ethernet networks using communication bridge modules. Simply install in any available chassis slot (except slot 0), configure addressing via RSLogix 5, and connect to your existing network infrastructure.
Q: What is the maximum I/O capacity supported by this PLC-5/15 processor module?
A: The 1785-LT/B supports up to 3,072 discrete I/O points across multiple local and remote chassis. Actual capacity depends on your system architecture, communication network configuration, and I/O module selection. For large-scale systems, consult our engineering team for optimal rack layout and addressing schemes.
Q: What level of energy efficiency and operational cost savings can I expect?
A: The processor itself consumes approximately 7.5 watts during normal operation. Compared to relay-based control systems, PLC-based automation typically reduces energy consumption by 15-25% through optimized sequencing, reduced idle time, and preventive maintenance scheduling. Actual savings depend on application complexity and system utilization patterns.
Q: What are the environmental and installation requirements for this processor module?
A: The 1785-LT/B operates reliably in ambient temperatures from 0°C to 60°C (32°F to 140°F) with 5-95% relative humidity (non-condensing). It requires installation in a NEMA-rated enclosure (typically NEMA 12 or higher for industrial environments) with adequate ventilation. Ensure chassis power supply provides stable 5V DC at minimum 1.5A for the processor.
Q: Does this processor support remote monitoring, data logging, and SCADA integration?
A: Yes. The 1785-LT/B can connect to SCADA systems and HMI panels via DH+ protocol or through Ethernet communication modules (1785-ENET, 1756-ENBT with bridging). It supports standard Rockwell Automation protocols including EtherNet/IP (with appropriate gateway modules), Modbus (via protocol converters), and OPC connectivity for enterprise-level data integration and remote diagnostics.
Q: Can I upgrade from an older PLC-5 processor without rewiring my entire system?
A: Absolutely. The 1785-LT/B is designed as a drop-in replacement for most PLC-5 family processors. Existing I/O wiring, chassis configuration, and network connections remain unchanged. You'll need to upload your existing program, verify addressing compatibility, and download to the new processor. Our technical team can assist with migration planning and program conversion if needed.
To receive detailed application engineering support, system configuration recommendations, or competitive project pricing, please provide the following information to our automation specialists:
Our certified automation engineers will provide one-on-one consultation, system architecture recommendations, and comprehensive quotations within 24 business hours.
© 2026 NINERMAS COMPANY LIMITED. All rights reserved.
Original Source: https://ninermas.com