The Allen-Bradley 1770-KF2 is a high-reliability Data Highway communication interface module designed for PLC-5 and SLC programmable logic controller systems. Through RS-485 differential signaling and token-passing protocol, it enables deterministic multi-node networking at speeds up to 57.6 Kbps, ensuring stable data exchange and real-time control in industrial automation environments.
Ideal for manufacturing plants, process control systems, and legacy automation infrastructure requiring proven communication reliability. This module addresses challenges such as isolated controller islands, limited supervisory visibility, slow troubleshooting cycles, and lack of centralized data acquisition in distributed control architectures.
With standardized mounting and field-proven design, the 1770-KF2 offers seamless integration, long-term availability, straightforward maintenance, and broad compatibility with Rockwell Automation ecosystems. Suitable for system integrators, OEM machine builders, plant maintenance teams, and automation engineers seeking dependable legacy network solutions. Contact our technical team for compatibility verification and configuration assistance.
This module is engineered for industrial environments demanding high communication reliability, multi-controller coordination, and long-term system stability, particularly in:
To ensure optimal performance and compatibility, the 1770-KF2 module is designed with the following key parameters. For custom configurations or multi-drop network layouts, please provide your system architecture details for engineering review.
| Parameter | Specification |
|---|---|
| Communication Protocol | Data Highway (Token-Passing) |
| Network Topology | Multi-drop RS-485 Bus |
| Maximum Baud Rate | 57.6 Kbps |
| Maximum Network Nodes | 64 (including master/slave devices) |
| Cable Type | Belden 9463 or equivalent shielded twisted-pair |
| Maximum Cable Distance | 10,000 feet (3,048 meters) at 57.6 Kbps |
| Operating Voltage | 5V DC (supplied via backplane) |
| Operating Temperature | 0°C to 60°C (32°F to 140°F) |
| Storage Temperature | -40°C to 85°C (-40°F to 185°F) |
| Relative Humidity | 5% to 95% non-condensing |
| Mounting | 1770 I/O chassis slot (any available position) |
| Diagnostic Indicators | Power, Network Active, Module Fault LEDs |
| Certifications | UL Listed, CE Marked, RoHS Compliant |
Selection Recommendations: When specifying the 1770-KF2, consider the following factors: total number of networked devices, maximum cable run distances, existing chassis slot availability, required baud rate for your application cycle time, and environmental conditions (temperature, vibration, electrical noise). For systems requiring redundancy or fiber-optic media conversion, consult with our automation specialists to identify complementary components such as repeaters, isolators, or media converters.
Lead Time: In-stock units typically ship within 1-3 business days. Custom-configured or refurbished modules may require 5-10 business days depending on testing and certification requirements.
Warranty: All modules are backed by a minimum 12-month warranty covering manufacturing defects and functional failures under normal operating conditions. Extended warranty and advance-replacement programs are available upon request.
Technical Support: Comprehensive installation and commissioning assistance is provided, including remote configuration guidance, network topology review, and on-site startup services (subject to geographic availability and project scope).
Documentation Package: Each module ships with complete technical documentation including wiring diagrams, DIP switch configuration tables, RSLinx driver setup instructions, and troubleshooting flowcharts to streamline installation and reduce commissioning time.
Q: How do I integrate the 1770-KF2 Data Highway interface module with my existing PLC-5 system?
A: The module installs into any available slot in your 1770 I/O chassis. Configure the node address via DIP switches, connect shielded twisted-pair cabling to the terminal block, and add the module to your RSLinx communication driver. Detailed wiring diagrams and RSLogix 5 configuration examples are included in the user manual.
Q: What is the maximum number of PLC-5 controllers I can network using the 1770-KF2?
A: A single Data Highway network segment supports up to 64 addressable nodes, which can include PLC-5 processors, SLC controllers, HMI panels, and PC-based SCADA stations. For larger systems, multiple network segments can be bridged using routing modules.
Q: Can the 1770-KF2 communicate with modern ControlLogix or CompactLogix platforms?
A: Direct communication is not supported due to protocol differences. However, you can use an Ethernet/IP to Data Highway gateway (such as the 1756-DHRIO) to enable data exchange between legacy PLC-5 networks and contemporary Logix-based systems.
Q: What are the environmental requirements for installing the 1770-KF2 module?
A: The module operates reliably in ambient temperatures from 0°C to 60°C with 5-95% non-condensing humidity. It features conformal coating for enhanced resistance to dust, moisture, and corrosive atmospheres. Ensure adequate chassis ventilation and avoid direct exposure to water or chemical sprays.
Q: Does the 1770-KF2 support remote monitoring and diagnostics?
A: Yes, when connected to an RSLinx Gateway or FactoryTalk Linx server, the module enables remote access via VPN or cellular modem. This allows off-site engineers to monitor network health, retrieve diagnostic logs, and perform configuration changes without physical site visits.
Q: Is the 1770-KF2 compatible with fiber-optic cabling for long-distance installations?
A: The module itself uses RS-485 copper wiring. For fiber-optic extensions beyond the standard 10,000-foot limit, you can deploy RS-485-to-fiber media converters at each end of the fiber link, maintaining signal integrity over distances up to several kilometers.
For detailed application engineering, system integration quotes, or technical clarification, please provide the following information: project name and location, application type (process control, discrete manufacturing, infrastructure), number of networked nodes, required communication speed, cable run distances, existing PLC models and firmware versions, and any special environmental or certification requirements. Our automation specialists will respond with tailored recommendations and pricing within one business day.
© 2026 NINERMAS COMPANY LIMITED. All rights reserved.
Original Source: https://ninermas.com
Contact: sale@ninermas.com | +0086 187 5021 5667