The Allen-Bradley 1762-0W8/24 is an 8-point, 24V DC sourcing output module designed specifically for MicroLogix 1200 PLC systems. Through solid-state switching technology and optical isolation, it delivers reliable digital output control for industrial automation applications. This module enables precise control of solenoid valves, indicator lights, motor starters, and other 24V DC field devices.
Ideal for manufacturing plants, packaging lines, material handling systems, and process control environments, the 1762-0W8/24 helps solve common challenges such as insufficient I/O capacity, signal interference, and the need for flexible system expansion. It is particularly suited for machine builders, system integrators, OEM equipment manufacturers, and plant maintenance teams requiring dependable output expansion.
With standardized design and hot-swappable capability, this module offers fast installation, high reliability, excellent noise immunity, and seamless compatibility with existing MicroLogix 1200 architectures. Contact our application engineers for configuration assistance, wiring diagrams, and technical quotations.
The 1762-0W8/24 output module is engineered for applications demanding stable digital output control, system scalability, and high reliability, especially in:
To facilitate engineering design and procurement, we provide key specifications for the 1762-0W8/24 module. Custom configurations and extended I/O architectures are available based on project requirements.
| Parameter | Specification |
|---|---|
| Catalog Number | 1762-0W8/24 |
| Output Type | 24V DC Sourcing (PNP) |
| Number of Points | 8 (individually controlled) |
| Output Current | 0.5A per point (continuous), 4A total module maximum |
| Voltage Range | 20.4 - 26.4V DC (nominal 24V DC) |
| Isolation | 1500V AC optical isolation (field to logic) |
| Response Time | 50μs ON / 100μs OFF (typical) |
| Power Consumption | 150mA @ 24V DC (from backplane) |
| Operating Temperature | 0°C to 60°C (32°F to 140°F) |
| Storage Temperature | -40°C to 85°C (-40°F to 185°F) |
| Humidity | 5% to 95% (non-condensing) |
| Enclosure Rating | Open-type (for use in NEMA/IP-rated enclosures) |
| Mounting | DIN rail or panel mount (via 1762 chassis) |
| Dimensions (H×W×D) | 87mm × 35mm × 80mm (3.43" × 1.38" × 3.15") |
| Weight | Approx. 0.15 kg (0.33 lbs) |
| Certifications | UL, cUL, CE, RCM |
Selection Recommendations: When specifying the 1762-0W8/24, consider the following factors: total number of output points required, load current per channel, field device voltage compatibility, environmental conditions (temperature/humidity/vibration), and available backplane power budget. For systems requiring sinking outputs, relay outputs, or AC voltage outputs, alternative modules are available. Our application engineers can review your I/O schedule and recommend optimal module combinations.
Standard stock items ship within 1-3 business days; custom-configured systems or bulk orders typically require 5-10 business days. All products include a 12-month manufacturer warranty covering defects in materials and workmanship. We provide remote technical support for installation, configuration, and troubleshooting; on-site commissioning services are available for select regions (subject to project scope and location).
Each module ships with complete documentation including: product datasheet, wiring diagrams, terminal block layout, I/O addressing tables, and quick-start installation guide. Technical support resources include application notes, sample ladder logic programs, and integration guides for common field devices.
Q: How do I connect the 1762-0W8/24 output module to my existing MicroLogix 1200 system?
A: The module installs directly onto the MicroLogix 1200 chassis via the backplane connector. Ensure the PLC is powered off, slide the module into an available expansion slot, secure with mounting screws, and connect field wiring to the removable terminal block. Configure I/O addressing in RSLogix 500 software according to the module's slot position.
Q: What is the maximum number of output modules I can add to a MicroLogix 1200 controller?
A: The MicroLogix 1200 supports up to 7 expansion modules total (any combination of input, output, analog, or specialty modules). Total backplane current consumption must not exceed the controller's power supply capacity (typically 1.5A @ 24V DC).
Q: Can this module drive 12V DC or 48V DC loads?
A: No, the 1762-0W8/24 is designed specifically for 24V DC loads (20.4-26.4V range). For 12V or 48V applications, use external interface relays or select alternative output modules rated for those voltage levels.
Q: What is the expected energy savings or efficiency improvement?
A: Solid-state outputs consume minimal power (typically <2W per module) compared to electromechanical relay modules. While direct energy savings are modest, the module reduces maintenance costs by eliminating relay contact wear, extends system uptime through faster response times, and improves process efficiency via precise output timing control.
Q: What are the environmental requirements for installation?
A: Operating temperature: 0-60°C; storage: -40 to 85°C; humidity: 5-95% non-condensing. The module is rated for open-type installation and must be mounted inside a NEMA 12/IP54 or better enclosure to protect against dust, moisture, and physical damage. Ensure adequate ventilation and maintain clearances per NEC/IEC standards.
Q: Does the module support remote monitoring and data acquisition?
A: Yes, when the MicroLogix 1200 is equipped with an Ethernet communication module (e.g., 1763-L16BBB or 1763-L16BWA), output status and diagnostic data can be accessed via EtherNet/IP, Modbus TCP, or web server interfaces. This enables integration with SCADA systems, HMI panels, and cloud-based IIoT platforms for real-time monitoring and predictive maintenance.
For detailed configuration recommendations, pricing, or application-specific technical support, please provide the following information: project name, application description, required I/O count (digital/analog inputs and outputs), load specifications (voltage/current per point), environmental conditions, and preferred delivery timeline. Our application engineers will respond within 24 hours with a customized solution proposal and competitive quotation.
© 2026 NINERMAS COMPANY LIMITED. All rights reserved.
Original Source: https://ninermas.com
Contact: sale@ninermas.com | +0086 187 5021 5667