(0 reviews)
Manufacturer:
Allen-Bradley (Rockwell)
Product No.:
1756-EN2T/D
Condition:
1000 in stock
Product Type:
ControlLogix 1756
Product Origin:
US
Payment:
T/T, Western Union
Weight:
1.00g
Shipping port:
Xiamen
Warranty:
12 months


Share:

Description

1756-EN2T/D Industrial EtherNet/IP Communication Interface (Conformal-Coated Edition)

The 1756-EN2T/D represents a mission-critical networking solution for ControlLogix and GuardLogix automation architectures requiring robust, dual-redundant Ethernet connectivity. This conformal-coated communication module delivers enterprise-grade network performance in challenging industrial environments where moisture, chemical exposure, and particulate contamination threaten system uptime.

Engineered for manufacturers and system integrators who demand zero-compromise reliability, the 1756-EN2T/D bridges distributed I/O networks, motion control systems, and supervisory platforms through standards-compliant EtherNet/IP protocol. Its dual-port architecture enables advanced Device Level Ring topologies that maintain continuous operation during cable failures or network disruptions.

Whether you're modernizing legacy control systems, expanding production capacity, or deploying greenfield automation projects, this module provides the scalable foundation for converged plant-floor networks supporting up to 256 simultaneous TCP connections across mixed-vendor ecosystems.

Core Capabilities & Business Value

→ Dual-Port Redundancy Architecture
Two independent 10/100 Mbps Ethernet ports enable Device Level Ring (DLR) configurations that automatically reroute traffic during link failures, eliminating single points of failure and reducing unplanned downtime by up to 40% compared to single-port alternatives.

✓ Conformal Coating Protection
Factory-applied protective coating shields critical circuitry from corrosive gases, condensation, and airborne contaminants—extending operational lifespan in food processing, chemical manufacturing, and outdoor installations where environmental exposure accelerates component degradation.

→ Embedded Web-Based Diagnostics
Integrated HTTP server provides browser-accessible network statistics, connection status monitoring, and configuration management without requiring proprietary software—reducing troubleshooting time by 60% and enabling remote diagnostics from any networked device.

✓ Native Studio 5000 Integration
Seamless compatibility with RSLogix 5000/Studio 5000 programming environments accelerates commissioning through auto-discovery features, pre-configured Add-On Instructions (AOIs), and unified tag databases that eliminate manual I/O mapping errors.

→ Scalable Connection Capacity
Supports 256 concurrent TCP connections enabling simultaneous communication with distributed I/O racks, variable frequency drives, HMI terminals, SCADA servers, and MES platforms—consolidating multiple network segments onto a single infrastructure.

✓ Industrial Temperature Range
0°C to 60°C operational specification ensures reliable performance in non-climate-controlled environments including warehouses, outdoor enclosures, and process areas with elevated ambient temperatures.

Industry Application Scenarios

Automotive Assembly Lines
Coordinate robotic welding cells, vision inspection systems, and conveyor networks across multi-zone production areas. The dual-port DLR topology maintains continuous operation during cable damage from material handling equipment, preventing costly line stoppages that average $22,000 per minute in lost production.

Food & Beverage Processing
Connect CIP cleaning systems, pasteurization controls, and packaging machinery in high-humidity washdown environments. Conformal coating resists chemical sanitizers and steam exposure that typically corrode standard electronics within 18-24 months.

Water Treatment Facilities
Network remote lift stations, clarifier controls, and chemical dosing systems across campus-wide installations. Extended temperature range supports outdoor equipment enclosures while embedded diagnostics enable predictive maintenance of critical infrastructure.

Pharmaceutical Manufacturing
Integrate batch reactors, clean room HVAC systems, and material tracking networks requiring 21 CFR Part 11 audit trails. VLAN segmentation isolates production networks from enterprise IT systems while maintaining centralized data collection for regulatory compliance.

Mining & Aggregate Processing
Link crusher controls, conveyor interlocks, and dust suppression systems in abrasive, high-vibration environments. Conformal coating protects against silica dust infiltration while DLR topology compensates for cable damage from mobile equipment.

Technical Specifications & Selection Criteria

ParameterSpecification
Catalog Number1756-EN2T/D
Network ProtocolEtherNet/IP (CIP on Ethernet)
Physical PortsDual RJ45 (10/100BASE-TX auto-sensing)
Topology SupportLinear, Star, Device Level Ring (DLR)
Max TCP Connections256 simultaneous
Data Rate10/100 Mbps (auto-negotiation)
Operating Temp0°C to 60°C (32°F to 140°F)
Power Draw3.5W @ 5V DC (typical)
Chassis CompatibilityControlLogix 1756 / GuardLogix
Environmental ProtectionConformal coating (Type /D)
CertificationsUL Listed, CE, C-Tick, RCM

Selection Guidance: Choose the 1756-EN2T/D variant when deploying in environments with exposure to moisture (>85% RH), chemical vapors, or airborne contaminants. For climate-controlled MCC rooms or clean industrial spaces, the standard 1756-EN2T offers identical communication performance at reduced cost. Verify chassis power budget accommodates 3.5W consumption per module when planning multi-module configurations.

Advanced Integration Features

VLAN Segmentation (IEEE 802.1Q)
Isolate production traffic from enterprise networks while maintaining centralized data collection. Configure up to 16 VLANs for departmental separation, quality of service (QoS) prioritization, or security zone enforcement.

SNMP v1/v2c Monitoring
Integrate with enterprise network management systems (NMS) for centralized health monitoring, bandwidth utilization tracking, and automated alerting when connection thresholds are exceeded.

Firmware Field Upgrades
Deploy feature enhancements and security patches through ControlFLASH utility without removing modules from chassis—minimizing maintenance windows and reducing change management complexity.

CIP Safety Protocol Support
When paired with GuardLogix controllers, transport safety-rated I/O data over standard Ethernet infrastructure, eliminating dedicated safety networks and reducing installation costs by 30-40%.

Delivery Timeline & Service Commitments

Standard Lead Time: 3-5 business days for in-stock units; 4-6 weeks for factory-direct orders during high-demand periods
Warranty Coverage: 12-month comprehensive warranty covering manufacturing defects and component failures
Technical Support: Unlimited email/phone consultation for configuration assistance, network troubleshooting, and firmware upgrade guidance
Documentation Package: Installation manual, quick-start guide, sample ladder logic, and EDS (Electronic Data Sheet) files included with every shipment

Frequently Asked Questions

What distinguishes the /D suffix from standard 1756-EN2T modules?
The /D designation indicates factory-applied conformal coating that protects circuitry from moisture, chemical exposure, and particulate contamination. Both versions share identical communication specifications—select /D for harsh environments or standard version for climate-controlled installations.

How does Device Level Ring topology improve network reliability?
DLR creates a redundant loop where traffic automatically reroutes through the alternate path during cable failures. Typical failover occurs within 3 milliseconds, maintaining continuous communication without manual intervention or PLC program modifications.

Can this module communicate with non-Rockwell Automation devices?
Yes—EtherNet/IP is an open standard (ODVA) supporting multi-vendor interoperability. The module communicates with any CIP-compliant device including third-party I/O, drives, and sensors that publish EDS files.

What cable specifications are required for optimal performance?
Use Category 5e or higher twisted-pair cable with maximum segment length of 100 meters (328 feet) between devices. For extended distances, deploy industrial Ethernet switches with fiber uplinks supporting up to 2 kilometers over multimode fiber.

Does the embedded web server require additional licensing?
No—web-based diagnostics are included as standard functionality. Access the interface by entering the module's IP address into any modern web browser; no plugins or proprietary software required.

How many modules can be installed in a single ControlLogix chassis?
Chassis capacity depends on slot count and power budget. A typical 10-slot chassis supports 4-6 communication modules when accounting for controller, I/O modules, and power supply limitations. Consult chassis power specifications to verify total backplane current availability.

Get Started with Your Network Upgrade

Ready to eliminate network vulnerabilities and future-proof your control system infrastructure? Our application engineers provide complimentary network architecture reviews to identify optimal module placement, DLR topology design, and VLAN segmentation strategies tailored to your facility requirements.

Contact our technical sales team today: Share your current network diagram and performance requirements to receive a customized implementation plan within 24 hours.

© 2026 NINERMAS COMPANY LIMITED. All rights reserved.
Original Source: https://ninermas.com
Contact: sale@ninermas.com | +0086 187 5021 5667

PDF Specification

Download PDF file here:

Click to Download PDF

Related products