Original Industrial Spare Part
Phoenix Contact 2703018 PP-RJ-SCC Retrofit RJ45 Module
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKUPP-RJ-SCC 2703018
- CategoryPLC & Industrial Automation Modules
- BrandPhoenix Contact
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: Phoenix Contact 2703018 PP-RJ-SCC Retrofit RJ45 Module with SKU PP-RJ-SCC 2703018.
Phoenix Contact 2703018 PP-RJ-SCC Retrofit RJ45 Module: Legacy System Compatibility and Smooth Upgrade
The Phoenix Contact 2703018 PP-RJ-SCC is a ruggedized RJ45 patch panel connector module engineered for demanding industrial environments. As automation facilities worldwide face the challenge of maintaining aging control infrastructure, this module has become a critical component in retrofit projects targeting legacy PLUSCON wiring systems, end-of-life communication backplanes, and discontinued patch panel assemblies. Whether you are upgrading a control cabinet that has been in service for over a decade or replacing a failed connector module in a production-critical system, the 2703018 PP-RJ-SCC delivers the mechanical and electrical compatibility required for a reliable, low-risk migration.
Designed to interface with standard RJ45 Ethernet and fieldbus cabling, this module supports direct installation into existing PLUSCON-series terminal carrier rails without requiring panel modifications. Its compact footprint and DIN-rail mounting compatibility make it suitable for control cabinets where installation space is constrained — a common challenge when retrofitting older enclosures that were not originally designed for modern communication-dense layouts.
Upgrade Compatibility Table
| Parameter | Legacy Configuration | 2703018 PP-RJ-SCC Retrofit |
|---|---|---|
| Interface Type | Proprietary patch panel or screw-terminal RJ45 adapter | Standard RJ45 (8P8C), PLUSCON-compatible carrier |
| Installation Method | Panel-mount or custom bracket | DIN-rail snap-on, direct carrier rail integration |
| Communication Compatibility | 10/100 Ethernet, PROFINET, EtherNet/IP (legacy wiring) | 10/100 Ethernet, PROFINET, EtherNet/IP, Modbus TCP |
| Replacement Recommendation | Discontinued patch panel modules, end-of-life RJ45 adapters | Direct drop-in for PLUSCON PP-RJ series; verify carrier rail pitch |
| Commissioning Focus | Re-termination of existing Cat5e/Cat6 cables; address reassignment | Confirm port labeling, cable routing, and network switch port mapping |
| Warranty | N/A (legacy, out of support) | 12-Month Warranty — covered by NINERMAS |
Retrofit Planning for Existing Automation Systems
Successful integration of the 2703018 PP-RJ-SCC into an existing automation system requires a structured pre-installation assessment. Before removing the legacy patch panel or connector assembly, engineers should document the current cable routing, port assignments, and network topology. In systems where the PP-RJ-SCC interfaces with a managed Ethernet switch — such as the Phoenix Contact FL SWITCH 2008 or FL SWITCH 2016 — it is essential to verify that VLAN configurations and port mirroring settings are preserved after the physical swap.
In control cabinets running PROFINET-based I/O, the PP-RJ-SCC typically sits upstream of distributed I/O modules such as the Phoenix Contact AXL F BK PN or the Axioline F I/O station. When replacing the patch panel connector, confirm that the PROFINET device name and IP address assignments remain consistent with the existing GSD file configuration in the PLC project. Any mismatch in device naming will prevent the controller — whether a Phoenix Contact RFC 470 PN 3TX or a third-party PROFINET master — from establishing communication after restart.
Power supply integrity is another critical checkpoint. The 2703018 PP-RJ-SCC itself is a passive connector module and does not draw significant current, but the surrounding infrastructure — including the Phoenix Contact QUINT-PS/1AC/24DC/10 power supply feeding the control cabinet — must be verified to confirm that the total load budget accommodates any additional active modules introduced during the retrofit. If the cabinet also houses a Phoenix Contact STEP-PS power supply for auxiliary circuits, ensure that both power rails are stable before energizing the upgraded communication segment.
For systems that include signal isolation between field devices and the control network, the retrofit plan should account for the Phoenix Contact MCR-SL signal conditioners or MINI MCR isolation amplifiers that may be installed adjacent to the patch panel. These devices are sensitive to ground loop changes that can occur when connector modules are replaced, so a continuity check of the shielding and grounding scheme is recommended before final commissioning.
In older installations where the control cabinet also houses a Phoenix Contact ILC 150 ETH or ILC 350 PN inline controller, the retrofit of the PP-RJ-SCC may coincide with a firmware update cycle. Coordinate the connector replacement with the controller maintenance window to minimize the number of separate planned outages. Similarly, if the cabinet includes a Phoenix Contact RAD-ISM-900 wireless module for remote I/O communication, verify that the wireless link remains unaffected by any changes to the wired Ethernet segment during the retrofit.
HMI connectivity should also be validated. If the system uses a Phoenix Contact TP 3057T or a third-party operator panel connected through the same Ethernet segment as the PP-RJ-SCC, confirm that the HMI screen tags and communication drivers are re-established after the module swap. A brief functional test of all HMI screens — including alarm pages and trend displays — should be completed before returning the line to production.
Downtime Control During System Migration
Minimizing unplanned downtime is the primary concern in any live-system retrofit. For the 2703018 PP-RJ-SCC replacement, the recommended approach is a hot-swap preparation strategy: pre-configure the new module on a bench, label all cables with their destination port assignments, and prepare a rollback plan that includes the original connector module or a temporary patch cable bypass.
Before initiating the physical swap, export and archive the current PLC program from the controller. This protects the original logic in the event that a communication fault during the retrofit triggers an unexpected program reset. If the system uses a Phoenix Contact AUTOMATIONWORX Software Suite or PC WORX programming environment, create a timestamped backup of the project file and store it on an offline medium.
During the swap window, isolate only the affected Ethernet segment rather than shutting down the entire control network. In systems with redundant communication paths — for example, where a media redundancy protocol (MRP) ring is configured across multiple FL SWITCH units — the ring topology will automatically reroute traffic around the disconnected segment, maintaining control continuity for the rest of the production line.
After installing the 2703018 PP-RJ-SCC, perform a structured commissioning sequence: verify link status LEDs on the connected switch port, confirm IP address resolution for all downstream devices, and execute a short I/O forcing test to validate that field signals are correctly mapped through the restored communication path. Document the commissioning results and update the as-built cabinet drawings before closing the maintenance window.
Retrofit Support FAQ
Q1: Is the Phoenix Contact 2703018 PP-RJ-SCC a direct replacement for older PLUSCON PP-RJ series modules?
A: Yes. The 2703018 PP-RJ-SCC is designed as a form-fit-function replacement for earlier PLUSCON PP-RJ patch panel connector modules. Verify the carrier rail pitch (typically 6.2 mm) and the number of ports required before ordering to ensure dimensional compatibility with your existing installation.
Q2: What commissioning steps are required after installing the 2703018 PP-RJ-SCC in a PROFINET system?
A: After physical installation, confirm that the PROFINET device name and IP address of all downstream I/O modules are correctly recognized by the PLC. Use the engineering tool (e.g., PC WORX or STEP 7) to perform an online device scan and compare the detected topology against the expected configuration. Resolve any device name conflicts before releasing the system to production.
Q3: Does NINERMAS provide pre-shipment testing for the 2703018 PP-RJ-SCC?
A: Yes. All units supplied by NINERMAS undergo functional verification prior to dispatch, including continuity testing of all RJ45 contacts and mechanical inspection of the carrier rail locking mechanism. A test report is available upon request for critical spare part orders.
Q4: What is the warranty coverage and stock availability for the 2703018 PP-RJ-SCC?
A: NINERMAS provides a 12-month warranty on all Phoenix Contact 2703018 PP-RJ-SCC units from the date of shipment, covering manufacturing defects and functional failures under normal operating conditions. Stock is maintained to support urgent retrofit and breakdown replacement requirements. Contact our team for lead time confirmation on large-quantity orders.
| Product Series | Other series |
|---|---|
| Country of Origin | DE |
Catalog Continuation
More Phoenix Contact modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
SKU: MINI-PS/12-24DC/5-15DC/2 2320018
Phoenix Contact MINI-PS/12-24DC/5-15DC/2 2320018 DC Power Supply
SKU: MINI MCR-SL-RPS-I-I 2864422
Phoenix Contact MINI MCR-SL-RPS-I-I 2864422 Safety-Reliable Signal Repeater
SKU: QUINT-PS/1AC/48DC/10 2866682
Phoenix Contact QUINT-PS/1AC/48DC/10 Retrofit Power Supply
SKU: 2320157 QUINT-DIODE'12-24DC/2x20/1x40
Phoenix Contact 2320157 Service-Ready Industrial Spare Part
Catalog Continuation
Alternative parts within PLC & Industrial Automation Modules.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
SKU: HDD02.2-W040N-HS12-01-FW FWA-DIAX04-ELS-05VRS-MS
Rexroth HDD02.2-W040N-HS12-01-FW Service-Ready Spare Part
SKU: I5DAE375F10010000S