Original Industrial Spare Part

Yokogawa ANR10D-423 ER Bus Node Unit | Original & New Spare Parts

Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.

SKU: ANR10D-423 SIS Safety & Redundancy Systems Yokogawa

RFQ Ready

Request pricing & availability

How Buyers Usually Use This Page

  • Confirm the exact part number and platform family before sending the quote request.
  • Use direct email when quantity, condition, and destination are already defined internally.
  • Switch to the broader brand or category archive when you need alternates nearby.

Series Navigation

Move through the most common platform families behind this part.

Yokogawa ANR10D-423 ER Bus Node Unit – Industrial Process Solution

From the perspective of a seasoned Industrial Solution Architect, few components carry as much operational weight as a reliable bus node unit in a distributed control environment. The Yokogawa ANR10D-423 serves as the critical communication backbone between Field Control Units (FCU) and distributed I/O modules within Yokogawa CENTUM VP and ProSafe-RS DCS platforms. Its dual-redundant ER Bus architecture ensures that Process Control integrity is never compromised — even when individual bus paths experience faults. In facilities where a single hour of downtime can cost hundreds of thousands of dollars, the Yokogawa ANR10D-423 is not merely a component; it is a safeguard.

What distinguishes this unit from generic alternatives is its engineered compatibility with the broader Yokogawa Fieldbus ecosystem. Unlike third-party substitutes that require costly re-engineering, the ANR10D-423 integrates natively with EB401 ER Bus Interface Master Modules and supports up to 8 I/O modules per node — covering analog, digital, RTD, thermocouple, and pulse-counting signal types. For engineers managing Legacy Components in aging DCS Hardware installations, this native compatibility eliminates the risk of signal drift, communication latency, and firmware conflicts that plague non-OEM replacements.

Original stock of this model is increasingly scarce. As Yokogawa transitions its product roadmap, Factory Sealed units of the ANR10D-423 represent a finite and diminishing supply. Procurement teams managing Maintenance Stock for critical infrastructure are advised to secure inventory proactively — this is a Critical Part for Industry Safety that cannot be substituted without significant re-engineering cost and risk.

Key Technical Highlights

Dual-Redundant ER Bus Architecture — Independent communication paths ensure zero single-point-of-failure exposure across the Distributed Control System network.
Multi-Power Input Support — Accepts 100-120 VAC / 220-240 VAC (50/60 Hz) and 24 VDC, enabling deployment across global facility standards without additional power conditioning.
8-Slot I/O Module Capacity — Accommodates up to 8 I/O modules per node, supporting high-density signal aggregation for complex process loops.
High-Speed Deterministic Communication — ER Bus protocol maintains low-latency, cycle-consistent data exchange critical for real-time Process Control applications.
Hot-Swap Module Replacement — Field technicians can replace individual I/O cards without interrupting the control loop, dramatically reducing Mean Time to Repair (MTTR).
19-Inch Rack Mount Form Factor — Standard industrial enclosure compatibility simplifies integration into existing DCS Hardware cabinets and control rooms.
IEC 61508 Functional Safety Alignment — When paired with ProSafe-RS controllers, supports SIL-rated configurations for Safety Instrumented Systems (SIS).

Vertical Industry Applications

Petrochemical & Oil Refining: In high-stakes refinery environments, the ANR10D-423 manages I/O communication for distillation column controls, heat exchanger monitoring, and emergency shutdown loops. Its redundant bus design ensures that a single cable fault does not cascade into a process trip, directly reducing unplanned downtime in facilities where continuous operation is non-negotiable.

Mining & Mineral Processing: Harsh vibration, dust, and temperature extremes characterize mining operations. This node unit’s industrial-grade construction and sealed module architecture maintain signal fidelity across conveyor control systems, crusher automation, and flotation cell management — environments where Legacy Components must perform reliably for decades.

Marine & Offshore Platforms: Offshore oil platforms and LNG carriers demand compact, redundant control architectures. The ANR10D-423’s dual-redundant Fieldbus design meets the stringent reliability requirements of marine automation, supporting ballast control, cargo monitoring, and engine room automation without requiring dedicated redundancy hardware.

Power Generation & Utilities: Turbine control, boiler management, and grid synchronization systems rely on deterministic I/O communication. The ANR10D-423 provides the stable, low-jitter data exchange that power plant DCS Hardware demands, supporting both baseload and peaking generation facilities.

Pharmaceutical & Fine Chemical Manufacturing: FDA-regulated batch processes require traceable, validated control architectures. The ANR10D-423’s native CENTUM VP integration supports 21 CFR Part 11 compliant data logging and audit trail functionality, making it a preferred choice for GMP-certified production environments.

Data Sheet & Specifications

Property Detailed Value
Complete Model Number ANR10D-423
Manufacturer Yokogawa Electric Corporation
Product Series CENTUM VP / ProSafe-RS ER Bus I/O
Function Dual-Redundant ER Bus Node Unit
Bus Architecture Extended Remote (ER) Bus, Dual-Redundant
I/O Module Slots Up to 8 modules per node unit
FCU Connectivity Up to 4 Field Control Units via ER Bus
Power Input Option 1 100-120 VAC, 50/60 Hz (200 VA, 120 W)
Power Input Option 2 220-240 VAC, 50/60 Hz (230 VA, 120 W)
Power Input Option 3 24 VDC (5.5 A consumption)
Mounting Standard 19-inch rack mount (M5 — 4 screws)
Unit Weight Approx. 10 kg (with 8 I/O modules installed)
Required Interface Module EB401 ER Bus Interface Master Module (odd-numbered slot)
Compatible DCS Platforms Yokogawa CENTUM VP, ProSafe-RS
Safety Standard Compliance IEC 61508 (SIL-rated configurations)
Condition Available Factory Sealed / New Surplus / Tested Refurbished
Warranty 12-Month Comprehensive Warranty
Origin Japan

Quality Assurance & Supply Chain

Every ANR10D-423 unit shipped by NINERMAS COMPANY LIMITED undergoes a rigorous multi-stage verification process before dispatch. Units sourced as Factory Sealed are inspected for intact OEM packaging, unbroken tamper-evident seals, and matching serial number documentation. New Surplus units are tested against Yokogawa’s published electrical and communication specifications using calibrated bench equipment. No unit leaves our facility without passing full functional verification.

Our global supply chain network maintains strategic inventory of critical Yokogawa DCS Hardware, specifically targeting EOL (End-of-Life) and hard-to-source Legacy Components that standard distributors no longer stock. This focus on obsolescence management means that when your plant faces an Emergency Repair scenario — a failed node unit threatening production continuity — we can respond with same-day quotation and next-flight-out shipping via DHL Express, FedEx International Priority, or UPS Worldwide Express.

12-Month Comprehensive Warranty covers all units against manufacturing defects and premature failure under normal operating conditions. Warranty claims are processed within 48 hours, with advance replacement units dispatched before the defective unit is returned — minimizing your facility’s exposure to extended downtime.

Buyer’s FAQ — Selection Guide

Q1: How do I verify that an ANR10D-423 unit is 100% original Yokogawa and not a counterfeit?
Authentic Yokogawa units carry a holographic OEM label on the module housing with a unique serial number traceable through Yokogawa’s global parts database. The PCB silkscreen should display Yokogawa’s internal part code alongside the model designation ANR10D-423. Request a photo of the label and PCB before purchase. NINERMAS provides full traceability documentation including original packing slip copies where available.

Q2: Can I obtain the official Yokogawa datasheet and wiring diagrams for the ANR10D-423?
Yes. Upon order confirmation, NINERMAS provides access to the relevant Yokogawa technical documentation package, including the ER Bus Node Unit installation manual, wiring topology diagrams, and I/O module compatibility matrix. For pre-sales technical consultation, contact our engineering team directly.

Q3: Is the ANR10D-423 compatible with older CENTUM CS 3000 systems, or only CENTUM VP?
The ANR10D-423 is primarily designed and validated for CENTUM VP and ProSafe-RS architectures. Compatibility with CENTUM CS 3000 depends on the specific FCU generation and ER Bus interface module version installed in your system. Our technical team can review your existing system configuration and confirm compatibility before shipment — preventing costly installation failures.

Q4: What is the lead time for ANR10D-423 units, and do you offer emergency delivery?
In-stock units ship within 24-48 hours of payment confirmation. For Emergency Repair situations, we offer priority processing with same-day dispatch on orders confirmed before 14:00 CST. International delivery via DHL/FedEx/UPS typically reaches major industrial hubs in Asia, Europe, and the Americas within 3-7 business days. Expedited next-flight-out options are available for critical shutdowns.

Q5: What is the difference between the ANR10D-423 and other ANR10D variants such as the ANR10D-410?
The suffix digits indicate the power supply configuration. The ANR10D-423 supports 220-240 VAC input (suffix -423), while the ANR10D-410 is rated for 100-120 VAC operation. Both variants share identical bus architecture, I/O slot count, and FCU connectivity specifications. Selecting the correct variant for your facility’s power infrastructure is critical — installing a 220V-rated unit on a 110V supply will result in insufficient power delivery and potential system instability.

Q6: Can the ANR10D-423 be used in a Safety Instrumented System (SIS) application?
Yes, when integrated with Yokogawa ProSafe-RS safety controllers and SIL-certified I/O modules, the ANR10D-423 supports Safety Instrumented System configurations compliant with IEC 61508. The dual-redundant ER Bus architecture provides the fault-tolerant communication backbone required for SIL 2 and SIL 3 rated safety loops. Consult your functional safety engineer to confirm the complete SIS architecture meets your target SIL rating.


© 2026 NINERMAS COMPANY LIMITED. All rights reserved. Original Source: https://ninermas.com | Contact: sale@ninermas.com | +0086 187 5021 5667

Product Series

ProSafe-RS

Country of Origin

JP

Reviews

There are no reviews yet.

Be the first to review “Yokogawa ANR10D-423 ER Bus Node Unit | Original & New Spare Parts”

Your email address will not be published. Required fields are marked

Catalog Continuation

More Yokogawa modules in the catalog.

Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.

Open this lane

Catalog Continuation

Alternative parts within SIS Safety & Redundancy Systems.

Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.

Open this lane

Industrial RFQ Support

Need a fast quote for a specific part number or system family?

Send your inquiry with brand, series, quantity, condition, and destination details. We will follow up on availability, lead time, and shipping options.

CallPhone MailEmail WAChat TopBack