Original Industrial Spare Part
MU-TAIH13 Honeywell High Level Analog Input FTA | Original Spare Parts
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKUMU-TAIH13
- CategoryDCS Distributed Control Systems
- BrandHoneywell
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: MU-TAIH13 Honeywell High Level Analog Input FTA | Original Spare Parts with SKU MU-TAIH13.
MU-TAIH13 — Honeywell High Level Analog Input FTA (Industrial-Grade, Original New)
As a procurement specialist sourcing critical spare parts for distributed control systems, you need components that deliver zero-compromise reliability. The MU-TAIH13 is a Honeywell-manufactured High Level Analog Input Field Termination Assembly (FTA) engineered for seamless integration within TDC 3000 and Experion PKS PLC System architectures. This module is 100% Brand New and Factory Sealed, sourced directly from authorized supply chains to meet the stringent demands of industrial automation environments.
Designed to address signal acquisition challenges in high-stakes process control loops, the MU-TAIH13 supports 16 differential analog input channels across 4-20 mA, 0-20 mA, and ±10V DC ranges. Whether you are maintaining an aging TDC 3000 infrastructure or expanding an Experion PKS Control Module network, this Original New spare part eliminates the risk of counterfeit components entering your critical systems. Procurement managers across Oil & Gas, Power Generation, and Chemical Processing trust this FTA for its proven field performance.
Every unit ships with full factory documentation, and our team provides end-to-end technical support from selection through commissioning. Contact us today for a fast quotation and lead time confirmation.
Technical Specifications & Selection Guide
| Specification | Value |
|---|---|
| Part Number / Model | MU-TAIH13 |
| Manufacturer | Honeywell |
| Module Type | High Level Analog Input FTA |
| Input Channels | 16 Differential Analog Inputs |
| Signal Range | 4-20 mA, 0-20 mA, ±10V DC |
| Resolution | 16-bit A/D Conversion |
| Accuracy | ±0.1% of Span |
| Input Impedance | 250Ω (Current) / 1MΩ (Voltage) |
| Isolation | Channel-to-Channel & Channel-to-Bus |
| Operating Temperature | 0°C to 60°C (32°F to 140°F) |
| Power Consumption | 5W Typical |
| Mounting | DIN Rail Compatible FTA Chassis |
| Compatible Systems | Honeywell TDC 3000, Experion PKS C200/C300 |
| Condition | 100% Original and Brand New |
Selection Tip: Verify your TDC 3000 or Experion PKS chassis slot assignments before ordering. The MU-TAIH13 is optimized for high-level signal inputs; for low-level thermocouple or RTD inputs, consult the Honeywell FTA selection matrix.
Core Features & Technical Advantages
Precision 16-Bit A/D Conversion — Delivers ±0.1% span accuracy, ensuring reliable process variable readings in high-stakes control loops.
Heavy-Duty Multi-Range Input — Each of the 16 channels is independently configurable for 4-20 mA, 0-20 mA, or ±10V DC, eliminating the need for signal conditioners.
Robust Galvanic Isolation — Channel-to-channel and channel-to-bus isolation suppresses ground loops and electrical noise common in industrial environments.
Hot-Swap Capability — Modules can be replaced under live system conditions, dramatically reducing unplanned downtime during maintenance windows.
Built-In Diagnostics — Integrated self-test routines and fault detection enable predictive maintenance strategies within your PLC System or DCS Control Module framework.
Compact High-Density Design — 16 channels per FTA maximizes cabinet real estate, a critical advantage in retrofit and expansion projects.
Typical Application Scenarios
Oil & Gas Upstream & Midstream: Wellhead pressure transmitters and flow meters generate continuous 4-20 mA signals that demand precision acquisition. The MU-TAIH13 handles these inputs with the accuracy and isolation required to prevent false trips in safety-critical loops.
Power Generation Plants: Turbine inlet temperature, steam pressure, and generator output monitoring rely on high-density analog input modules. This FTA integrates directly into existing TDC 3000 DCS racks, avoiding costly panel redesigns.
Chemical & Petrochemical Processing: Reactor temperature profiles and distillation column level measurements require multi-channel analog acquisition with galvanic isolation to protect against hazardous area ground faults.
Pharmaceutical Manufacturing: FDA-regulated batch processes demand traceable, high-accuracy analog data. The MU-TAIH13’s 16-bit resolution supports the data integrity requirements of validated control systems.
Water & Wastewater Treatment: Flow, pH, and turbidity transmitters across distributed pump stations benefit from the module’s robust design and compatibility with Experion PKS C300 controllers managing remote I/O networks.
Logistics & Professional Service
✅ 2-Day Express Shipping Available — Urgent plant shutdowns and emergency maintenance windows are accommodated with priority dispatch from our warehouse.
? 1-Year Warranty — Every MU-TAIH13 unit is covered against manufacturing defects and workmanship failures for 12 months from the date of shipment.
? Factory-Sealed Packaging — All units are shipped in original Honeywell packaging with full documentation, including datasheets and certificates of conformance upon request.
? EOL Legacy System Support — We specialize in sourcing Original New spare parts for end-of-life TDC 3000 and legacy Honeywell DCS platforms, ensuring your installed base remains operational without forced migration.
? Technical Pre-Sales Support — Our engineering team assists with compatibility verification, FTA selection, and system integration planning at no additional cost.
Frequently Asked Questions
Q: What is the price of the MU-TAIH13, and are volume discounts available?
A: Pricing for the MU-TAIH13 is competitive and reflects the 100% Original and Brand New condition of every unit. Volume pricing tiers are available for orders of 5 units or more. Contact sale@ninermas.com with your quantity and project timeline for a customized quotation. We also offer blanket order arrangements for maintenance, repair, and operations (MRO) programs.
Q: Is this module compatible with both TDC 3000 and Experion PKS systems?
A: Yes. The MU-TAIH13 is a Honeywell Original spare part fully validated for use in TDC 3000 FTA chassis and Experion PKS C200/C300 I/O subsystems. It supports seamless migration between these platforms within the same Industrial Automation infrastructure.
Q: Can I obtain a Datasheet or Certificate of Origin for this part?
A: Absolutely. Official Honeywell datasheets and certificates of origin are available upon request for all MU-TAIH13 orders. These documents support your incoming inspection, quality management system (QMS) requirements, and regulatory compliance audits.
Q: What is the typical lead time for the MU-TAIH13?
A: In-stock units ship within 1-2 business days. For larger quantities or special configurations, lead time is typically 5-7 business days. Emergency orders can be expedited — contact our team directly for same-day processing options.
Q: How do I verify the authenticity of the MU-TAIH13 I receive?
A: Every unit supplied by NINERMAS COMPANY LIMITED is 100% Original and Brand New, traceable to authorized Honeywell distribution channels. Factory serial numbers, holographic labels, and original packaging are intact on all shipments. We provide full traceability documentation upon request.
Q: Does the MU-TAIH13 support HART protocol?
A: The MU-TAIH13 provides high-accuracy analog signal acquisition over standard 4-20 mA loops. Native HART pass-through requires a dedicated HART multiplexer or HART-enabled Control Module within your Experion PKS or TDC 3000 PLC System architecture.
© 2026 NINERMAS COMPANY LIMITED. All rights reserved. Original Source: https://ninermas.com | Contact: sale@ninermas.com | +0086 187 5021 5667
| Product Series | Experion PKS (C200/C300) |
|---|---|
| Country of Origin | US |
Catalog Continuation
More Honeywell modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
Catalog Continuation
Alternative parts within DCS Distributed Control Systems.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
Reviews
There are no reviews yet.