Original Industrial Spare Part

Allen-Bradley 1756HP-TIME ControlLogix Precision Time Sync Module

Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.

SKU: 1756HP-TIME PLC & Industrial Automation Modules Allen-Bradley (Rockwell)

RFQ Ready

Pricing by RFQ

How Buyers Usually Use This Page

  • Confirm the exact part number and platform family before sending the quote request.
  • Use direct email when quantity, condition, and destination are already defined internally.
  • Switch to the broader brand or category archive when you need alternates nearby.

Series Navigation

Move through the most common platform families behind this part.

Allen-Bradley 1756HP-TIME | Reliable Automation Component for Precision Time Synchronization

Field Application & Operational Analysis

From the perspective of a Site Reliability Engineer managing distributed control architectures, the Allen-Bradley 1756HP-TIME stands as a cornerstone automation component for achieving system-wide temporal coherence. In mission-critical environments — power generation, petrochemical processing, and advanced discrete manufacturing — the 1756HP-TIME implements IEEE 1588-2008 Precision Time Protocol (PTPv2) to deliver ±1 microsecond synchronization accuracy across EtherNet/IP networks, directly reducing unplanned downtime caused by timestamp misalignment and event sequencing errors. Its role in process optimization cannot be overstated: coordinated motion control, sequence-of-events recording, and distributed data logging all depend on a single, authoritative time reference that this module reliably provides.

Engineered for operational excellence in harsh industrial environments, the 1756HP-TIME is rated for continuous operation from 0°C to 60°C and draws only 3.5W from the ControlLogix backplane — minimizing thermal load in densely populated chassis. Installation demands attention to network topology: PTP-aware managed switches are strongly recommended to preserve hardware-timestamping integrity across multi-hop paths. The module mounts in any standard 1756 chassis slot and is fully configurable via Studio 5000 Logix Designer, eliminating the need for external configuration utilities and streamlining system integration workflows.

For SREs and maintenance engineers responsible for uptime KPIs, stocking the 1756HP-TIME as a critical spare is a non-negotiable reliability strategy. As a legacy and end-of-life (EOL) component with constrained global availability, securing verified original inventory in advance prevents extended mean-time-to-repair (MTTR) during unplanned failures — a discipline central to operational excellence in any I/O module-dependent architecture.

Key Operational Features

Sub-Microsecond Synchronization: ±1µs typical accuracy via IEEE 1588 PTPv2 hardware timestamping — far exceeding NTP-class performance for mission-critical automation components.
Flexible Clock Topology: Operates as PTP grandmaster, boundary clock, or transparent clock — enabling seamless integration into existing EtherNet/IP network hierarchies.
External Reference Input: Accepts GPS, IRIG-B, and NMEA sources for absolute UTC traceability, supporting regulatory compliance in power and utility sectors.
High Availability Design: Automatic leap-second handling, daylight saving transitions, and network topology change recovery maintain synchronization continuity without operator intervention.
Redundancy Support: Maintains bumpless transfer timing in redundant ControlLogix pairs, preserving system availability during controller switchover events.
Broad Certification Coverage: UL, cUL, CE, ATEX, IECEx — qualified for use in hazardous area classifications across global industrial installations.

Maintenance & Performance Benchmarks

The 1756HP-TIME adapts to industrial network architectures of varying scale and complexity. In small-cell deployments (fewer than 20 PTP clients), the module operates as a standalone grandmaster with minimal configuration overhead. In mid-scale architectures (20-100 nodes), boundary clocks at each network segment preserve synchronization fidelity across managed switch boundaries. For enterprise-scale installations exceeding 100 synchronized devices, the module integrates with hierarchical PTP domain structures, distributing time references across multiple chassis and remote I/O drops without degradation.

Firmware diagnostics expose real-time offset, path delay, and clock quality metrics directly within Studio 5000, enabling predictive maintenance workflows. Engineers can set alarm thresholds on synchronization drift to trigger alerts before timing errors propagate into process control logic — a proactive approach that aligns with modern SRE practices for I/O modules and automation components in continuous-process environments.

Comprehensive Data Sheet

Attribute Technical Data
Model Number 1756HP-TIME
Brand Allen-Bradley (Rockwell Automation)
Product Family ControlLogix 1756 Series
Product Type High-Precision Time Synchronization Module
Time Protocol IEEE 1588-2008 PTPv2
Synchronization Accuracy ±1 microsecond typical (network-dependent)
Internal Resolution 1 nanosecond
Clock Source Internal oscillator; optional GPS / IRIG-B / NMEA input
Network Interface EtherNet/IP via ControlLogix backplane
PTP Update Rate 1 — 128 packets per second (configurable)
Operating Temperature 0°C to 60°C (32°F to 140°F)
Power Consumption 3.5W typical at 5V DC (backplane-powered)
Mounting ControlLogix 1756 chassis slot (any slot)
Dimensions (W — H — D) 35mm — 147mm — 132mm
Certifications UL, cUL, CE, ATEX, IECEx
Configuration Tool Studio 5000 Logix Designer
Condition New & Original, Factory Packaging
Warranty 12 Months

Professional Logistics & Sourcing Excellence

Every 1756HP-TIME unit dispatched from our inventory is supplied in original factory packaging with full manufacturer labeling and traceability documentation intact. For in-stock orders, same-day dispatch is available upon order confirmation before the daily cut-off — minimizing production line exposure during emergency replacement scenarios. Our global supply network specifically addresses EOL and legacy module procurement challenges: we maintain verified stock of discontinued and hard-to-source automation components to support facilities operating long-lifecycle control systems where OEM availability has lapsed. Worldwide express logistics partnerships ensure delivery to major industrial hubs across Asia-Pacific, Europe, the Americas, and the Middle East within 3-7 business days under standard conditions.

Engineering Support & FAQ

Q1: What are the installation prerequisites for the 1756HP-TIME in an existing ControlLogix chassis?
A: The module requires a 1756 chassis with available backplane slot and a compatible version of Studio 5000 Logix Designer (v21.00 or later recommended). PTP-aware managed switches are required on the EtherNet/IP network to preserve hardware-timestamping accuracy. No external power supply is needed — the module draws power directly from the backplane.

Q2: Which firmware versions are compatible with the 1756HP-TIME?
A: The module is compatible with ControlLogix controller firmware v20.00 and above. For full PTP grandmaster functionality and advanced diagnostic features, firmware v28.00 or later is recommended. Always verify compatibility against your specific controller catalog number using Rockwell’s Product Compatibility and Download Center (PCDC).

Q3: Can the 1756HP-TIME synchronize third-party, non-Rockwell devices?
A: Yes. The module distributes IEEE 1588 PTPv2 time to any compliant device on the EtherNet/IP network — including third-party servo drives, data acquisition systems, and intelligent sensors — regardless of manufacturer, provided those devices support PTPv2 as slave clocks.

Q4: How does the warranty claim process work?
A: All units carry a 12-month warranty from the date of shipment. In the event of a verified manufacturing defect or component failure, contact our technical support team with the order reference and fault description. Replacement or repair is processed within 5 business days of fault confirmation, with express return shipping covered for warranty cases.

Q5: Is GPS input mandatory for the module to function?
A: No. The 1756HP-TIME operates fully with its internal oscillator for relative time synchronization across the local network. GPS, IRIG-B, or NMEA inputs are optional and only required when absolute UTC traceability is mandated by regulatory or process requirements.

Q6: How many PTP client devices can a single 1756HP-TIME support?
A: The module imposes no hard limit on PTP client count. Practical capacity depends on network bandwidth and switch architecture; typical deployments synchronize 50-200 devices per grandmaster instance. For larger installations, boundary clock configurations distribute the synchronization load across network segments.

Product Series

ControlLogix 1756

Country of Origin

US

Reviews

There are no reviews yet.

Be the first to review “Allen-Bradley 1756HP-TIME ControlLogix Precision Time Sync Module”

Your email address will not be published. Required fields are marked

Catalog Continuation

Likely ControlLogix 1756 platform matches.

These parts are closer to the same platform family signaled by the current SKU and title, so buyers can validate continuity before sending a final RFQ.

Open this lane

Catalog Continuation

More Allen-Bradley (Rockwell) modules in the catalog.

Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.

Open this lane

Catalog Continuation

Alternative parts within PLC & Industrial Automation Modules.

Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.

Open this lane

Industrial RFQ Support

Need a fast quote for a specific part number or system family?

Send your inquiry with brand, series, quantity, condition, and destination details. We will follow up on availability, lead time, and shipping options.

CallPhone MailEmail WAChat TopBack